ML20148H966
| ML20148H966 | |
| Person / Time | |
|---|---|
| Site: | Yankee Rowe |
| Issue date: | 08/18/1975 |
| From: | Office of Nuclear Reactor Regulation |
| To: | |
| Shared Package | |
| ML20148H962 | List: |
| References | |
| NUDOCS 8011200195 | |
| Download: ML20148H966 (1) | |
Text
(.-,1) l v-v (2) At entiu ptver, the esteulated tempnret... ef tho ecclent
? *.
ct tha exit sof tha hottset channsi chalf nnt excazd 624*F.
Q) At rated power. the calculated maximum cl.ad surface rature in the' hottest channel shall not exceed d.
V.ain Coolant System (1) The reactor shall be scrammed automatically by a low primary pressure trip signal at 1800 psig whenever the -reactor is 112 critical.
(2) The reactor shall be scrammed automatically above 15 MW electric by low main coolant flow signals derived from 118 6P across the steam generators and main coolant pump current.
Low flow scram will be initiated by low flow in two of four loops. When the plant is operating with three loops; the low flow trip will be initiated by low flow in any one of the three operating loops.
-(3)' The reactor chall be scrar=ed aute=atically by high pres a surtzer voter level signal act at a maximt.s of 200 inches
.before the reactor la critical.
(4) The reactor shall not be brought to'critica.lity at a main coolant system temperature lower than 250 F and system preanure lower than 300 puig except for scheduled low power physics testing which shall be performed in accordance with y.
written procedures."
(5) During normal plant startup boric acid dilutton shall not be 4
commenced until the main coolant system temperature has reached equil brium at 250 ?.
- (6)
At zero power, except durin;; physics testing, the moderator temperature coefficient shall not be positive.
At rated steady state, power, the moderator temperature coef ficient shall be core
' e ga tiv e th r.n -0. 5 x,10-4 A k/ k p e r
- F. "
n (7)
Tne nain coolant syrtem pressure must not execes 500 ps2g until the temperature of the matn coolant is at. least.600F above the nil docttitty temperature of the reactor vessel.
~
Pressures in exc'ess of this at low temperatures may be i
injurious to the reactor vessel.
(6)
The main coolant systch hcatup and cooldown rate rnest not j
cxeced 600F/hr.
The pressurazer heatup and cooldown rato j
must not exceed 2000F/hr.
(9) M.cnever a main coolant loop is isolated from the system, it shall be borated at full shutdown concentrations before it's temperature is reduced 300F below the highest cold lec temperature of the operating loops.
. "Following isolation of a main coolant loop,'when the loop' isolation valve and main coolant pump controlo have been
.. removed from service and mechanically prevented from operation by lock and key,, the boron concentration In the isolated *.oc.p may be reduced to that, exist. - ; in' the c.ain coolant system at
.that time."
Note: The underlined requirement n D.2.d(2)- to be effective as of date of startup with Core XII.
g ygg l
- son u on S-
_