{{#Wiki_filter:, Osmmonwealth FAli' ion Company liraidwood Generating station 'O Route al, Ikix H1 liraceville,11. 60107-9619 Tel H15-442801 9& i May 19,1997 l United States Nuclear Regulatory Commission Attention: Document Control Desk l Washington, D.C. 20555 0001

Subject:

Braidwood Nuclear Power Station, Units 1 and 2 l Additional Information Pertaining to Submittal of Relief Requests NR-27,28,31, and 34 i NRC Docket Nos 50-456 and 50-457

References:

1. H. G. Stanley (Comed) letter to Document Control Desk (USNRC) Revision 4 of the Inservice Inspection Plan for Braidwood Station Units 1 and 2, dated October 8,1996. 2. George F. Dick (USNRC) letter to Irene M. Johnson (Comed), Request for AdditionalInformation Regarding First 10-Year Inservice inspection Program - Braidwood Station (TAC Nos. M97134 and M97135), dated March 19,1997. 3. H. G. Stanley (Comed) letter to Document Control Desk (USNRC) Braidwood Nuclear Power Station, Units 1 and 2 Response to Request for Additional Information, dated March 28, j 1997. ll /g\\f> With Reference 1 Commonwealth Edison (Comed) transmitted Revision 4 of Braidwood's ISI Plan. Included in that submittal was relief request NR-27, NR-28, and NR-31. Subsequent to that submittal the StalTissued a request for additional information via Reference 2, which Comed responded to in Reference 3. As stated in Reference 3, Relief Request NR-27, NR-28 and NR-31 would be revised to include a discussion of the limitations of performing the exam, subsequent to the vessel inspection. Additionally, a new relief request, NR-34, would be submitted to address the limitations encountered during the 10CFR50.55a augmented reactor vessel examination. These relief requests were to be provided to the Staff by April 30,1997. As discussed with the StafT, due to a delay in data analysis, Braidwood would be submitting the revised relief requests prior to the end of May. Finally, based on conversations with the Staff, Relief Requests NR-27, 9706060208 970519 A Unicom Compan)

- - -.. ~. -. - - -. -. ~. _ 1 Document Control Desk Page_2 i l NR-28 and NR-31 have been revised to reflect only the Unit I results. Relief requests for i Unit 2 will be submitted aller performance of the Unit 2 reactor vessel inspection. Attached are the revised Relief Requests for NR-27, NR-28, NR-31, and the new Relief Request NR-34. Please address any comments or questions regarding this matter to T. W. Simpkin, at (815) 458-2801 extension 2980.~ J \\ Very truly yours, $9

i. Gene tanley Site Vice President Braidwood Nuclear Generating Station hgs /fh97044 doc j

Attachments cc: A. B. Beach, Regional Administrator - Rill G. F. Dick, Braidwood Project Manager - NRR C. J. Phillips, Senior Resident inspector - Braidwood Office of Nuclear Facility Safety - IDNS Michael T. Anderson, INEL Research Center j l i

l i Revision 1 l RELIEF REQUEST NR-27 COMPONENT IDENTIFICATION I Code Class (es): 1 I

Reference:

IWB-2500-1 t i Examination Categories: B-D Item Numbers: B3.90

== Description:== Volumetric Examination of Reactor Pressure Vessel l f Nozzle to Vessel Welds I Component Number (s): Unit 1 Welds: 1RV-01-006, 1RV-01-009, 1RV-01-010, 1RV-01-013 l-l CODE REQUIREMENT Subsection IWB, Table IWB-2500-1, Examination Category B-D, Item B3.90 requires essentially.100% volumetric examination of the region described in Figure IWB-2500-7 for Reactor Pressure Vessel (RPV) nozzle-to-vessel welds. l f -RASIS FOR RELIEF Comed's Braidwood Nuclear Power Station Units 1 conducts ISI activities in { accordance with the 1983 Section XI Edition, 1983 Summer Addenda as required by i . Title 10, Code of Federal Regulations, Part 50, Section 55a, Paragraph (g),. Subparagraph (4) (10 CFR 50.55a (g) (4)]. Pursuant to 10 CFR 50.55a (g) (6) (1), relief is requested on the basis that the code requirement to examine essentially 100% of the welds' volume is impractical due to geometric interference. All RPV welds are examined using remotely. operated underwater volumetric inspection l techniques. Underwater volumetric inspection techniques are utilized to meet ALARA concerns due to the high radiation levels in these areas. The outlet (Hot Leg) nozzles are constructed with an integral extension on the I.D. surface which mates with the internal core barrel. The extension provides a flow path for reactor coolant from the core into the hot leg nozzles. The integral extensions partially obstructs the circumferential scan for reflectors transverse to the weld (Reference ). The integral extension, that confines the movement of the transducer package, along with the curvature of the RPV shell combine to limit full Code volume coverage when scanning in the direction parallel to the weld (Reference Attachment 2). This configuration limits the examination aggregate volume coverage obtained for each weld and adjacent base metal to approximately 84% instead of the Code required essentially 100% examination coverage. Compliance with the applicable Code requirements may be accomplished by redesigning and modifying the ID of the Hot Leg nozzles and/or the building structure surrounding the RPV at the nozzles' elevation. Braidwood Unit 1 RPV was designed with a RPV shield wall (Reference Attachment 3 and 4). This wall impedes access to the OD of the RPV shell for insulation removal, surface preparation and ultrasonic inspection. Modifying the nozzle ID surface would incur extensive radiation exposure to station personnel and could be detrimental to the component. When designing, fabricating and installing these welds, strict ASME Section III quality controls and procedures were-used that minimized the introduction of fabrication defects. Additionally,.the periodic VT-2 examinations in accordance with the

. - ~ ~ -.. _... .. -. -. -. _... -.....-.-..... - _ ~.. ~.. -., RELIEF REQUEST NR-27 (cont.) [ Revision 1 l. l requirements of ASME Section XI, Table IWB-2500-1, Examination Category B-P and l applicable Reactor Coolant system monitoring requirements specified in the Technical I Specifications will provide reasonable assurance of continued structural integrity of the Reactor Vessel. Comed has recently performed these volumetric examinations . to the fullest extent practical, i.e. 84%, during the AlR06 refuel outage and no recordable indications (NRI) were detected. The NRI results of the examination j l provide further assurance that unacceptable inservice flaws have not developed in the subject welds. Thus, the modification of the nozzles and/or the building l structure to increase examination volume coverage from 84% to essentially 100% would l l incur unnecessary. radiological exposure and significant engineering costs without a l l compensating increase in the level of quality and safety. PROPOSED ALTERNATE PROVISIONS i (Hot Leg) nozzle welds will be examined to the fullest i The Reactor Vessel outlet extent ' practical using the available underwater volumetric inspection techniques. l } } APPLICABLE TIME PERIOD This relief request will be required for the First Ten Year Inspection Interval. 5 APPROVAL STATUS Pending NRC review. ) 1 J l g g y .r ,r- .#,.y ,+-e. .m ,+, -. - -., 7

Revision 1 l NR-27 ATTACHMENT 1 (Drawing not to scale) ) +- 9. 6 8 7 5 " -* i l (- -) Represents u Code Volume BMT/2 1 - Q __________ u BMT/2 R=BMT/2 I Jb 1 \\// a 4 i J L HORIZONTAL SECTION VIEW l 41 55" = ______________2__8_._9_7_"_____________________________________,_____________________. 57.75" VERTICAL SECTION VIEW 1 r 1r /\\\\ ^ w R=BMT/2 BMT/2 _________ { u +- 9. 6 8 7 5 " -+ BMT/2 i Reactor Vessel Outlet Nozzle Note: BMT is abbreviation for Base Metal Thickness

Revision 1 NR-27 ATTACHMENT 2 (Drawing not to scale) (- -) Represents Code volume w N ..M?~T- ./ \\//_, J; a 6 HORIZONTAL SECTION VIEW Transducer Package j .......................................................................................,/... VERTICAL SECTION VIEW , r /\\\\ 9 m 3 _....... { \\ RPV Qutlet Nozzle Coverage Plots for Scans for Reflectors Oriented Transverse to the Weld (0 45 and 60 Exams)

Revision 1 NR-27 ) ATTACHMENT 3 (Drawing not to scale) 1.0' ) 8.5" 1 i WTiir gg L. 2 Aga m m I Jf:P Ak'n M5j e4 y y a p: 5% vlin,S s i4!qy am 1 7~ SS$:.' W'. ? ?y; Y$. $? nt"; a de -:ss: 4 4 d

3 w

A ? B n L ~ [g; l ~ N b ~~ A. p. jn. fxEiwram \\H OUTLET NOZZLE TO VESSEL WELD s-g tinsulnan - w g ; g ; ; N. A _s.---- c 2;'m =ls jLasfut n;

5%gth.

7

  1. !!@44 g,s..

i 'x m A La ~u ib!$d*f@i !O s Reactor Vessel Outlet Nozzle (with support) Interference Detail

Revision 1 NR-27 ATTACHMENT 4 (Drawing not to scale) l l i REACTOR 1 VESSEL :' SHIELD ! WALLi-f \\ / 51.25" outer [ Nozzle DIA. \\ [Ms s s / 63125": DIAL I I opening. / l xs'q~v',, / y / N / y / ^ j' g / \\ N ~ ~il IReactorlVessel? isupport! Reactor Vessel Outlet Nozzle (with support) Section A-A Interference Detail

.__-m ) l Revision 1-l RELIEF REQUEST NR-28 ~ CGEPONENT IDENTIFICATION i Code Class (es) - 1 I I i L

Reference:

IWB-2500-1 Examination Categories: B-D f Item Numbers: B3.100 Description Alternative rules for the Inservice Inspection of l Reactor Pressure Vessel Nozzle Inner Radius Sections l (IRS) l Component Number (s); Unit 1 Welds: 3RV-01-015, 1RV-01-016, 1RV-01-019, 1RV-01-020 l l i CODE REQUIREMENT ) Subsection IWB, Table IWB-2500-1, Examination Category B-D, Item B3.10U requires essentially 100% volumetric examination of the inner radius region described in i Figure IWB-2500-7 for Reactor Pressure Vessel (RPV) nozzle inner radius sections. l ) RAsIS FOR RELIEF Comed's Braidwood Nuclear Power Station Unit 1 conducts ISI activities in accordance with the 1983.Section XI Edition,.1983 Summer Addenda as required by Title 10, Code of Federal Regulations, Part 50, Section 55a, Paragraph g, Subparagraph 4 (10 CFR I

50. 55a (g) (4 ) ).

Pursuant to 10 CFR 50.55a (g) (6) (i), relief is requested on the basis that the code requiren.ent to examine essentially 100% of the each inner radius section is impractical due to the geometry. l i All of the inner radius sections of the RPV nozzles are examined using remotely l operated underwater volumetric inspection techniques. Underwater volumetric inspection techniques are utilized to meet ALARA concerns due to the high radiation levels in these areas. Examination of the inner radius sections of the anlet (Cold Leg) nozzles is limited by the nozzle gecmetry (Reference Attachment 1 and 2). The design of the underwater volumetric inspection equipment was unable to scan the l radius area where it transitions from the shell into the nozzle bore. This geometry limits the volumetric examination aggregate volume coverage obtained for the nozzle inner radius section to about 82% instead of the essentially 100% Code required exam volume. Compliance with the applicable Code requirements may be accomplished by redesigning i and modifying the nozzles' inner radius section and/or the building structure i surrounding the RPV at the nozzl3s' elevation. -Braidwood Unit 1 was designed with a i RPV shield wall-(Reference Attaenment 3 and 4). This wall impedes access to the OD I of the RPV shell for insulation removal, surface preparation and ultrasonic .d:pection. Modifying the nozzle ID surfaces surface woul'd incur extensive . radiation exposure to station personnel. j i. 1 Based on industry experience, no operating issues to date have been identified in ~ PWR no? iner radius sections. If an inservice flaw were to develop in this j i l'

regior,

,aw would be expected to initiate at the ID surface. A visual j inspect .-1) of the entire-ID IRS surface provides reasonable assurance j l l-l

l Revision 2 l RELIEF REQUEST NR-28 (cont.) that unallowable inservice flaws have not developed in the subject area. Additionally, the periodic VT-2 examinations in accordance with the requirements of l ASME Section XI, Table IWB-2500-1, Examination Category B-P and applicable Reactor Coolant system monitoring requirements specified in the Technical Specifications will provide reasonable assurance of continued structural integrity of the Reactor Vessel. Comed has recently performed these volumetric examinations to the fullest extent practical, i.e. 82%, during the AlR06 refuel outage and no recordable indications (NRI) were detected. The NRI results of the examination provide further assurance that unacceptable inservice flaws have not developed in the subject areas. Thus, the modification of the nozzles and/cr the building structure to increase l examination coverage from 82% to essentially 100% would incur unnecessary radiological exposure and significant engineering costs without a compensating l increase in the level of quality and safety. PROPOSED ALTERNATE PROVISIONS i The Reactor Vessel inlet (Cold Leg) nozzle inner radius sections were examined to l l the fullest extent practical using the available underwater volumetric inspection technique. In conjunction with the partial volumetric examination, a supplemental VT-1 of the nozzle inner rad _us area was conducted from the interior of the Peactcr Vessel using underwater camera equipment. l APPLICABLE TIME PERIOD Thd.s relief request will be required for the First Ten Year Inspection Interval. APPROVAL STATUS Pending NRC review. I l 1 l

m._. j 1 Revision 1 l l NR-28 ATTACHMENT 1 l i (Drawing not to scales l 1 +- 9.6875" -* l j l BMT/2 j }.......... \\ P3 T/2 ] (- - ) Repres ent s Code Volume [ \\// s, db l See Detail A HORIZONTAL SECTION VIEW .............2.747."........................................................................ 61.00" i VERTICAL SECTION VIEW I 1/2" a.:.-_ _- /\\\\ \\ R=BMT/2 BMT/2 ......... g +- 9. 6 8 7 5 " -+ BMT/2 l i Reactor Vessel Inlet Nozzle i I l Note: BMT is abbreviation for Base Metal Thickness

... ~ _. ~ Revision 1 l NR-28 ATTACHMENT 2 i (Drawing not to scale) I l l l l l I i t I t 1 Approximate Cire. Scan Coverage-I I N -mm 1/2" g-XQ Volume Not Inspected i. I I, Detail A .e I

} P Revision 1 NR-28 ATTACHMENT 3 (Drawing not to scale)

1. 0'

= +-- 6.5" $N$ l 5942 4 wauwe '$ <..m ?!$$5j7 4:.; ' 1[:0.,e. 74 .. ids t w.f,v..uM..M f }Ds.. J @gjM,! 1 n %g y. jyff ^ g % ; 8., \\ % ;,.y. ~ 3 'aftG: ,:o;::-: 7v e tmp da. Mw%N, ~,if.. I A ~ ! hh i.:h:N, .x 3-i ] I N ,c 1 /. ,/.- gggmyg--c \\// ~ INLET NOZZLE TO VESSEL WELD / \\\\ ananauw g ~] x#.s [,...... . _.\\..i.0 g . 7 15( $N!L.5A 9 !@JQ)Rf, ?) ..a A

uesasgs

.m$, nw a#-u,,.a.n:a.. n.%.z, ~u m 3v,.x.,l..>e. m

v. :.:.

.m . s. m..- ,p,-,e t.a,. <.m.

;+y aan

<gpsha" Reactor Vessel Inlet Nozzle (with support) Interference Detail

Revision 1 NR-28 ATTACHMENT 4 (Drawing not to scalet

i...
B REACTORfVESSELPSHIELDjWALL

) fj;. ~% s,. 'y ,/ 55.5" outer Nozzle DIA. ' ew \\ N \\ \\ \\ // .s (( \\\\ i 67"-DIA. \\\\ lj i Opening: \\\\ \\ \\\\ m-. - -.. N c4. - x x \\ / N N %._.____.-- i i _g 1 Reactor Ves'sel -- Support j ._u.' Reactor Vessel Inlet Nozzle (with support) Section A-A Interference Detail

, -.. _ - _ _ ~ - -. - _ -. _. - ~ ~. -. Revision 1 l RELIEF REQUEST NR-31 i COMPONENT IDENTIFICATION .i I Code Class (es): 1 'I

Reference:

IWB-2500-1, Table IWB-2500-1 Examination Categories: B-A i Item Number (s): Bl.11 f

== Description:== Volumetric Examination of Reactor Pressure Vessel f (RPV) Circumferential Shell Weld. j component Number (s): Unit 1 Weld: 1RV-02-002 l l CODE REQUIREMEFT i i Subsection IWB, Table IWB-2500-1, Examination Category B-A, Item Number Bl.11 l requires essentially 100% volumetric examination of the RPV Circumferential l l Shell welds as detailed in Figure IWB-2500-1. l I BASIS FOR RELIEF l Comed's Braidwood Nuclear Power Station Units 1 conducts ISI activities in [ accordance with the 1983 Section XI Edition, 1983 Summer Addenda as required-by l Title 10, Code of Federal Regulations, Part 50, Section 55a, Paragraph (g), Subparagraph (4) (10 CFR 50.55a (g) (4 )]. Pursuant to 10 CFR 50.55a (g) (6) (i), relief. is. requested on the basis that the code requirement to examine essentially 100- of the weld volume is impractical due to geometric interference. 10CFR 50.55 a (g) (6) (ii) (A) (1) revokes all relief requests with respect to volumetric examination coverage for welds specified in Item Bl.10. Portions of a previously granted relief request, NR-9, addressed limited exam coverage on the Braidwood RPV shell welds Examination of the subject RPV shell weld was conducted on Braidwood Unit I during AIR 06 refuel outage (Spring 1997). During this exam at Braidwood Unit 1, physical obstructions and geometry prevented ultrasonic (UT) coverage in t excess of 90% of the required volume. The examination of the Lower Shell l Course-to-Dutchman weld, 1RV-02-002, is restricted by six (6) core barrel locating lugs welded to the inner surface of the vessel approximately 2.5 t f -inches above the weld centerline (See Attachment 1). These lugs obstruct the automated UT examination tool from examining the Code required volume of the j weld and base material under and below each lug in both the circumferential I' and perpendicular scan directions (156' total for all 6 lugs, see Attachment ' 2, 3 and 4). All weld metal and base material can be examined between the lugs (204* total length between all 6 lugs). The 6 lug interferences limit the examination aggregate volume coverage obtained for the weld and adjacent j base metal to approximately 81% of the Code required volume. Compliance with the applicable Code requirements may be accomplished by redesigning i and modifying the RPV and/or the building structure surrounding the vessel (s). l Access for manual inspections from the OD of the RPV is limited because of the close proximity of the building structure to the RPV shell (See Attachment 1). l r Examination of the Code required examination volume was completed to the maximum i cxtent practical using alternate UT techniques qualafied to the highest standard I b I

._. _~. 1 l l Revision 1 RELIEF REQUEST NR-31 (cont. ) available. RPV examinations were conducted from the I.D. of the vessel. Access to allow examination from the O.D. (shell side) of these welds is restricted due to the structural concrete surrounding the vessel. The examination techniques employed have been demonstrated and qualified to the Performance Demonstration Initiative (PDI) Program which meets the intent of the rules of Appendix VIII of the ASME Code, Section XI, 1992 Edition with 1993 Addenda. These techniques were used in place of the currently required Section XI, 1983 Edition with Summer 1983 Addenda, technique, i (Reference Relief Request NR-29). Although the techniques have been qualified at PDI for single direction scanning, examinations were performed from two directions, when required (i.e., performed from both sides of the weld on the same surface, where feasible). Strict ASME Section III quality controls were used when designing, fabricating, anu installing these RPV welds. Preservice (PSI) examinations to the fullest extent practical were performed on these welds. PSI relief request 1NR-9 was submitted to i the Staff and approved for these lug interferences. Comed has recently performed these ultrasonic examinations to the fullest extent practical, i.e. 814, during the AIR 06 refuel outage and no unacceptab]e indications to applicable Section XI standards were detected. The results of the examination provide further assurance that unallowable inservice flaws have not developed in the subject weld. In addition to UT, visual examinations (VT-1 and VT-2) of the weld also verifies its integrity. Thus, the modification of the RPV and/or the building structures to increase examination volume coverage from 81% to essentially 100s would incur unnecessary radiological exposure and significant engineering expenses. Braidwood Station believes this course of action is a hardship witbout a compensating inctease in the level of quality and safety. PROPOSED ALTERNATE PROVISIONS The ultrasonic examination of the Braidwood Unit 1 RPV shell weld, 1RV-02-002, wan performed to the maximum extent practical. In conjunction with the partial ultrasonic exandnation, a supplemental VT-1 of the RPV shell weld was conducted fro:: the interior of the RPV using underwater camera equipment. APPLICABLE TIME PERIOD l This relief request will be required for the First Ten Year Inspection Interval. APPROVAL STATUS Pending NRC review. i o i 1

+ Revision 1 l NR-31 (Drawing not to scale) ) =204" Cavity Diameter f =191" Reactor Diameter ~, Y sin by. ; l f ' QTS BMT(1)=8.625" s-

inn,

......,.:.'9, ..I

s;;..,.........

4 -- flCO...NCRETE s Of a.6 m...- = =....... =. N inBUILDINGt LSTRUCTUREg: S ~l U L t A T. BMT(1)/2 I' r 3% e ~ O 1.50" + 4,, I db 2.14" 4 .5 ~- 3 BMT(2)/2 4P $hldNBdkWeen) lRPVfhhNdhiNitig BMT(2)=5.625" w' BMT = Base Metal Thickness Code Volume (. .) = Core Support Lug Detail

Revision 1 l NR-31 (Drawing not to scalen i 4 a 4 Un-obstructed Scan Area l Transducer Package l l Reactor Vessel Shell Core Support Lug l ~, .x. 'f;',:. v'g N l. N . _=. s' 4,. - s ..,n ~c s. 7. y i ~__ w-{" f% ?' s l 'Jl ,a r s i \\ l / i l t \\ l / i \\ l / 's l ,/ \\, i, l / g Obstructed Scan Area (Below Lugs) Exam Coverage Between Core Support Lugs for Reflectors Oriented Transverse to the Weld

., ~.... i Revision 1 l NR-31 (Drawing not to scale) I i t i J k l l 1 i i 4 3 's ' s ' r s \\ N N code Volume (- ) -e - Transducer Package js s s \\. N, N yxx s z.xx x'N s s 'x'x'N ' s R \\

  • m

\\s, N \\s \\... \\. x.. s\\. :s.. 3 w i 1 i l Exam Coverage Under Core Support Lugs for Reflectors Oriented Parallel to the Weld

Revision 1 l NR-31 (Drawing not to scale) k code volume (.. .) . l[ Transducer Package E E i Exam Coverage Under Core Support Lugs for Reflectors Oriented Transverse to the Weld

._.m.____.___ ___ _.__._ _ _____ ____.m r' Revision 0 RELIEF REQUEST NR-34 i CCBEPONENT IDENTIFICATION I l Code Class (es): 1 1

Reference:

10CFR50. 55a (g) (ii) ( A) (2) IWB-2500-1, Table IWB-2500-1 l I l Examination Categories: B-A i i j Item' Number (s): Bl.ll i

== Description:== Volumetric Examination of Reactor Pressure Vessel (RPV) Circumferential Shell Welds. Component Number (s): Unit 1 Weld: 1RV-02-002 l I l CODE REQUIREMENT l 10CFR50. 55a (g) (ii) (A) (2) requires that all licenses shall augment their Reactor Pressure Vessel (RPV) examination by implementing once, as part of the j inservice inspection interval in effect on September 8, 1992, the examination requirements for the RPV shell welds specified in Item Bl.10 of Examination Categorf B-A, " Pressure Retaining Welds in Reactor Vessel", in Table IWB-2500 - l 1 of Suosection IWB of the 1989 Edition of Section XI, Division 1, of the ASME I Boiler and Pressure Vessel Code. For the purpose of this augmented examination, " essentially 100%" as used in Table IWB-2500-1 means'more than 90% of the examination volume of each weld, where the reduction in coverage is 1 ( due to interference by another component, or part geometry. BASIS FOR RELIEF Pursuant to 10 CFR 50.55a (g) (ii) (A) (5), relief is requested f rom the requirement -t o examine more than 90% of the examination volume of.the RPV circumferential shell weld, 1RV-02-002, on'the basis that the alternative to the examination requirements would provide an acceptable level of quality and safety. l 10CFR 50.55 a (g) (6) (11) (A) (1) revokes all relief requests with respect to j volumetric examination coverage for RPV shell welds specified in Item Bl.10. Portions of a previously granted First Interval relief request, NR-9, addressed limited exam coverage on the Braidwood RPV shell welds. Augmented examination of the subject RPV shell weld was conducted on Braidwood j Unit 1 during AIR 06 refuel outage (Spring 1997). During this exam at L Braidwood Unit 1, physical obstructions and geometry prevented ultrasonic (UT) coverage in excess of 90% of the required volume. The examination of the -Lower Shell Course-to-Dutchman weld, 1RV-02-002, is restricted by six (6) core . barrel locating lugs welded to the inner surface of the vessel-approximately 2.5-inches above the weld centerline'(See Attachment 1). _These lugs obstruct the automated UT examination tool from examining the Code required volume of weld and base material under and below each lug in both the circumferential i and perpendicular scan directions (156' total for all 6 lugs, See Attachment . 2, 3, and 4). All weld metal and base' material can be examined between the lugs (204

  • total length between all 6 lugs). The 6 lug interferences limit

'the. examination-aggregate volume coverage for.the weld and adjacent base metal to approximately 81% of the Code required volume. b* i e i I

~ ~ l Revision 0 l RELIEF REQUEST NR-34 (cont.) i l Compliance with the applicable Code requirements may be accomplished by redesigning and modifying the RPV and/or the building stru:ture surrounding the vessel (s). Access for manual inspections from the OD of the RPV is l limited because of the close proximity of the building structure to the RPV shell (See Attachment 1). Examination of the Code required examination volume was completed to the maximum extent practical using alternate UT techniques qualified to the highest standard available. RPV examinations were conducted from the I.D. of the vessel. Access to allow examination from the O.D. (shell side) of these welds is restricted due to the structural concrete surrounding the vessel. The examination techniques employed have been demonstrated and qualified to the Performance Demonstration Initiative (PDI) Program which meets the intent of the rules of Appendix VIII of the ASME Code, Section XI, 1992 Edition with 1993 Addenda. These techniques were used in place of the currently required Section XI, 1983 Edition with Summer 1983 Addenda, techniques (Reference Relief Request NR-29). Although the techniques have been qualified at PDI for single direction scanning, examinations were performed from two directions, when required (i.e., performed from both sides of the weld on the same surface, where feasible). Strict ASME Section III quality controls were used when designing, fabricating, and installing these RPV welds. Preservice examinations to the fullest extent practical were performed on these welds. Preservice Inspection (PSI) relief request 1NR-9 was submitted to the Staff and approved for these lug interferences. Comed has recently performed these ultrasonic examinations to the fullest extent practical, i.e. 81+, during the AlR06 refuel outage and no unacceptable indications to applicable Section XI standards were detected. The results of the examination provide further assurance that unallowable inservice flaws have not developed in the subject weld. In addition to UT, ) visual examinations (VT-1 and VT-2) of the weld also verifies its integrity. Thus, the modification of the RPV and/or the building structures to increase 1 examination volume coverage from Bl* to more than 90% would incur unnecessary radiological exposure and significant engineering expenses. Braidwood Station believes this course of action is a hardship without a compensating increase in the level of quality and safety. PROPOSED ALTERNATE PROVISIONS The ultrasonic examination of the Braidwood Unit 1 RPV shell weld, 1RV-02-002, was performed to the maximum extent practical. In conjunction with the i partial ultrasonic examination, a supplement.1 VT-1 of the RPV shell weld was conducted from the interior of the RPV using underwater camera equipment. APPLICABLE TIME PERIOD This relief request will be required for the First Ten Year Inspection Interval APPROVAL STATUS Pending NRC review. t l

EeVisic.i 0 NR-34 (Drawing not to scale) I =204" Cavity Diameter sp .,..it:0 < ;q[' 4 =191" Reactor Diameter ,"+ f-s,. ;.; ym N 8 > J, v 's' 1 5 "5f,[ BMT(1)=8.625" ~ l ,j ,..v-..-#-e.,.4........-< ,.ve. 5 ^ nCONCRETET -I l 4 0: BUILDING'< N (STRUCTURE S .O .L 1 h >m.;.,.. f BMT (1) / 2

.s e WR ~

qqi j. r t? .O... 1.50" S:N s-2.14" i "v 1, BMT (2 ) /2 d. ?....-.. -....;.3 -.,c.:.;I-wagoMaetweeni! ] '.RPV$$ddjBUilding + -. - y):'" ? BMT ( 2 ) = 5. 62 5 " g:-. 2 BMT = Base Metal Thickness Code Volume (. .) = i Core Support Lug Detail a

- -.. - _ ~...... ~. ReViSiCD 0 NR-34 i (Drawing not to.=cale) i i d l J i -- Un-obstructed Scan Area Transducer Package l i Reactor Vessel Shell Core Support Lug i i , u -[ . -l 'N 1s -'^ x -s;. -s., s ['* w.s' 4 q, \\ / i +i l 'N. 8 / x. / s i lQN) // f '.. S - ..l., / \\ \\ i ~/ j' l k.s 'N i s \\ l ,/ \\ \\ i l N / i 's l / i i \\ l / \\ i \\ \\ l / y s a g \\ Obstructed Scan Area (Below Lugs) Exam Coverage Between Core Support Lugs for Reflectors Oriented Transverse to the Weld

l Revision 0 NR-34 l (Drawing not to scale) i 1 i 1 k i 1 t y \\ s f N ,\\' N 's r N, ',.. l Code Volume (. .) 'N,N,N N s, N s. s' r s. f-- Transducer Package \\ s_ NNN x f s s 'N [ N xx x\\, gK \\ N ,s sg, s 'N s \\ x \\ j 1 l l l w d Exam Coverage Under Core Support Lugs for Reflectors-Oriented Parallel to the Weld J

i Revision 0 4 NR-34 .l i. a i l e i r i Code Volume (- -) Transducer Package

s. '

i j i Exam Coverage Under Core Support Lugs for Reflectors Oriented Transverse to the Weld}}