Responds to NRC Compliance Bulletin 87-002, Fastener Testing to Determine Conformance W/Applicable Matl Specs. Based on Encl Technical Evaluation,No Fastener Discrepancy Noted in Tests Adversely Affects safety-related Components
ML20148G012
Person / Time
Site: North Anna  
Issue date: 01/18/1988
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
87-705A, IEB-87-002, IEB-87-2, NUDOCS 8801260380
Download: ML20148G012 (51)


Text

_ _ _ _. _ _ _ _ _ _ _ _ _ - _ _

VINGINIA ELECTRIC AND Powan CoxPAxy Ricitwoxn,VIHOINIA 202 61 W.L.srswAur Vaca Passionst January 18, 1988 x m.. o,. m io,.

United States Nuclear Regulatory Commission Serial No.

87-705A Attention: Document Control Desk N0/RCB jmj Washington, D.C.

20555 Docket Nos. 50-338 50-339 License Nos. NPF-4 NPF-7 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNITS 1 AND 2 RESPONSE TO NRC COMPLIANCE BULLETIN 87-02 The information requested by the NRC Compliance Bulletin No. 87-02, "Fastener Testing to Determine Conformance with Applicable Material Specifications" is attached for North Anna Power Station.

This information consists of the following:

1. - A response to Bulletin 87-02 Action Item 1 providing a written description of the:

a.

Characteristics currently examined during receipt inspection of fasteners; b.

Internal controls utilized during storage and issuance of stock to assure the appropriate use of fasteners.

A technical report containing responses to Bulletin

2.

87-02 Action Items 2 through 5 including:

a.

Completed fastener testing data sheets (Attachment I

to Bulletin 87-02) for each of the forty-one (41) samples; b.

Completed data summary sheet (Attachment 2 to Bulletin 87-02) for the forty-one (41) samples.

c.

Technical evaluations for the out-of-specification fasteners.

Although we have concluded that no fastener discrepancy identified during this testing adversely affects safety related components, we intend to further evaluate our current procedures and practices to determine if any further actions need to be taken to assure continued compliance with fastener i

specifications and requirements.

We will either identify any subsequent corrective actions, if applicable, or provide a schedule for completion of this activity by February 29, 1988.

8801260300 880118 PDR ADOCK O yB G

I

The information provided in this response is true and accurate to the best of my knowledge.

If additional information is required, please let us know.

Very truly yours, l

W. L. Stewart Attachments cc:

U. S. Nuclear Regulatory Commission 101 Marietta Street, N.W.

Suite 2900 Atlanta, GA 30323 l

l Mr. J. L. Caldwell l

NRC Senior Resident Inspector North Anna Power Station l

l l

l

W ENCLOSURE 1 RESPONSE TO NRC IE BULLETIN 87-02 ACTION ITEN 1 RECEIPT INSPECTION AND INTERNAL CONTROLS NORTH ANNA POWER STATION 1.

DESCRIBE THE CHARACTERISTICS CURRENTLY EXAMINED DURING RECEIPT INSPECTION OF THE FASTENERS a.

Receipt inspection of fasteners includes the following:

(1) Verification of diameter and length.

(2) Random check of threads with thread gage.

(3) Verification that ASTM /ASME head or end markings are correct.

(4) Verification of heat number and code identification to certified material test report (CMTR).

(5) Check of chemical and physical data on CMTR to ASTM /ASME requirements, when applicable.

(6) Verification of manufacturer's Certificate of Conformance (C of C), when applicable.

(7)

Inspection for damage, correct quantity, and documentation accuracy.

2.

DESCRIBE THE INTERNAL CONTROLS UTILIZED DURING STORACE AND ISSUANCE FROM STOCK TO ASSURE THAT APPROPRIATE USE OF FASTENERS a.

Internal controls are applied as follows:

(1) Fasteners are normally tagged individually with stock number, storage level, purchase order (P.O.) number, heat number, ASME code class, and safety related. Fasteners may be bulk packaged with one tag and later subdivided as stated in subparagraph (3) below.

(2) For safety-related fasteners, a QA Acceptance Tag is affixed by the inspector.

Stores personnel do not release fasteners unless this tag is affixed. These tags are inspected as part of QA's maintenance monitoring activities.

(3)

If threaded bar is cut, a Quality Control inspector witnesses the suidivision and provides additional acceptance tags or stickers.

(4) Station administrative procedures require Maintenance Engineering review and approval of safety-related fasteners in pressure boundary applications on ASME code class components that are over 1" diameter nominal pipe size.

ENCLOSURE 2 TECHNICAL EVALUATION NRC COMPLIANCE BULLETIN 87-02 FASTENER TESTING TO DLTERMINE CONPORMANCE WITH APPLICABLE MATERIAL SPECIFICATIONS NORTH ANNA POWER STATION UNITS 1 AND 2 e

P a

j

s TECHNICAL EVALUATION NRC COMPLIANCE BULLETIN 87-02 e

i 1.

Introduction In response to NRC Compliance'Bulletir 87-02, Virginia Electric and Power Company (Virginia Power) tested selected fasteners for conformance to the chemical and mechanical property sections of the applicable material standard. This report contains the results of this testing as well as the disposition. of any fasteners that.did not meet the detailed requirements of the standard.

2.

Testing Method The fasteners to be tested were selected in accordance with NRC Compliance Bulletin 87-02.

Only safety related fasteners are procured for pressure boundary or structural support applications.

There are a small percentage of fasteners which are procured as non-safety related and which are maintained as stock items. However, this stock is procured from the original equipment manufacturer, by part number, to meet original specifications and dedicated to non-safety reinted applications.

Additionally, fasteners 1/4" or smaller are stocked as non-safety related based on limited availability of testing and certification documentation.

Inventoried fasteners which are stocked for general plant use are stocked as safety related fasteners. Therefore, based on these practices, we 1

only included safety related fasteners in our sample plan. Attachment 1 to this enclosure contains the completed fastener testing data sheets for each of the 41 samples.

Virginia Power contracted with Law Enginaering Testing Company to perform the chemical and mechanical analyses. Law Engineering is a qualified laboratory, on Virginia Power's approved vendor list.

Testing methods were in accordance with the requirements of the applicable material standards. When deemed to be useful, testing beyond the requirements of the bulletin, such as elongation and reduction of l

area measurements, were performed in accordance with the ASTM standards.

Chemical analysis was performed on all samples. Hardness testing and tensile tests were performed on bolts, capscrews, threaded bar, etc.

which were sufficiently long for testing. Hardness tests were performed on nuts and bolts as required.

l 3.

Test Results e to this enclosure lists the results of the testing.

The format is similar to Attachment 2 to NRC Compliance Bulletin 87-02.

Fasteners which do not meet all requirements of the applicable standard are noted with a "*".

In addition, the specific property (ies) not

+

meeting the requirements are each noted with a "*".

I k

c r-e D

N

(

a j[

4 '.

Evaluation of Results

c

.)

Each fastener whibh did not meet all. requirements of the applicable standard is evaluated, based on the importance of_the specific property with respect to application and environment, where applicable.

The following is an item by item discussion of each deviation that was identified.

4.1 NPF4-AB, -AC, -AE and -AR For these samples the elongation was out of specification as indicated /in Attachment 2.

All other properties conformed to the specification.

Ductility is considered a qualitative,' subjective property of.a material. Conventional measurements of ductility from tension tests are elongation and reduction of area.

The significance of ductility for bolts is to indicate to the designer the ability of the metal to flow plastically before fracture. A high dustility indicates that tb material is "forgiving" and likely to deform locally without fracture should the designer err in the stress calculation or the prediction of severe loads.

Even though the lower measured values of percentage-elongation for these materials indicate somewhat lower ductility, the measured value of percentage reduction of area being within the specification indicates adequate ductility of the material.

Therefore, the measured differences in value of percentage elongation for these specimens are considered to be insignificant and not sufficient cause to remove any fasteners already placed in service.

4.2 NPF4-A0 and -AP For these samples, hardness and elongation were out of specification as indicated on Attachment 2.

These properties indicate that the material was not solution annealed after cold-working. This was verified by metallographic section. Although the fasteners do not pose a problem from a stress view, this metallurgical structure is more susceptible to stress corrosion cracking.

Fasteners procured under this purchase order were reviewed and were found not to have been used in any safety related systems. The remaining supply of these fasteners will be removed from stock to prevent any further use of this material.

4.3 NPF4-AS The ultimate tensile strength was out of specification. The minimum strength specified is 125 ksi and the measured strength was 123 ksi.

All other mechanical and chemical properties conformed to the specification.

This represents an ultimate strength of about 1%

below the specified value; however, other measured properties were acceptable.

This deviation is considered to be insignificant and not sufficient cause to remove any fasteners already placed in service.

I ATTACIDENT 1 NRC ENFORCEMENT BULLETIN 87-02 FASTENER TESTING DATA SHEETS 42-SMA-6015B-9

l FASTIGEElt TESTING DATA SHEET

  • Sample IDf; NPF4-AB 3

Fastener

Description:

' 1/2"-13 x 5" Bolt, stud, continuously threaded Description of Sample Stock Location:

CA IB 03 03 01 Material Specification as Documented by Licensee Records: ASTM-A-193 Gr B7 Head Marking (Specification and Manufacturer):

B7 T

    • Class / Procurement Levels - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Energy Steel & Supply 2715 Paldan Drive Auburn Hills MI 48057 Manufacturer Texas Bolt Co.

P.O. Box 1211 Houston, TX 77251-1211 P.O. #: NS-124679 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFRi? and 10CFR50, Appendix B Licensee Representative:

Engineering f

//

,M Date

[

Approved

[Af((

Date

/ / 8k Station agliir 74-VTM-1322-2

FASTENER TESTINC DATA SHEET

  • Sample IDf: NPF4-AC Fastener

Description:

1/2"-13 x 5" Bolt, stuo, continuously threaded Description of Sample Stock Location: CA 1B 03 03 01 Material Specification as Documented by Licensee Records:

ASTM-A-193 Gr B7 Head Marking (Specification and Mcnufacturer):

B7 T

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Hardware Specialty 48-75 36th Street Long Island City, NY 11101 Manufacturer: Texas Bolt Co.

P.O. Box 1211 Housten TX 77251-1211 P.O. f: NS-34310 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative:

/!/[

Engineering

[

d.-

a Date T Ad I dr/w

,,, - ed

//

cat.

Station h

74-kTM-132 2-3

?

FASTENER TESTING DATA SHEET

  • Sample IDf: NPF4-AD Fastener Descriptions-5/8"-11 x 5" Bolt, stud, continuously threaded 4

g Description of' Sample Stock Location: CA 1B 03 05 01 t

Material Specification as Documented by Licensee Records: ASTM-A-193 Gr B7 i

Head Marking (Specification and Manufacturer): N B7 l

4 I'

    • Class / Procurement Levels - Safety Related i

General Plant Application (e.g., Pressure Boundary, Structural) i i

Pressure Boundary i

Supplier NOVA Machine Products Corp.

I P.O. Box 30287 i

Middleburg Heights, Ohio 44130 l

Manufacturer: Nova Machine Products Corp.

P. O. Box 30287

[

Middleburg Heights, Ohio 44130 i

P.O. f:

SNS-147693 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME i

Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B i

I Licensee Representative:

/

M Date

//[

Engineering

/ /J [7 Approved

[#/['/

Date j'

Station n'ger

/

i l

f i

f i

I j

74-WTM-1322-4 i

i I

i

?

k

.,--_.1m.,e

, ~ -,...,. _..

4.-

q

-FASTENER TESTING DATA SHEET 2

  • Sample ID#:-lNPF4-AE Fastener'

Description:

5/8"-11 x 5" Bolt, stud, continuously threaded Description of Sample Stock Location:' W5 PR 1E 03 02 01 Material: Specification as' Documented by Licensee Records: ASTM-A-193 Gr B7 i

Head Marking (Specification and Manuf acturer): C B7

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Sales Systems Limited r

700 Florida Ave.

Portsmouth, VA 23797 Manufacturer: Cavalier Bolt & Nut 5188 Cleveland St.

Virginia Beach, VA 23402 P.O. #: NS-13656 QA Requirements Imposed on Vendor: Manufacturer's Certificate of Compliance Certificate of Conformance-Licensee Representative:

//[ [

Engineering If

/2, Date i

[Mk[

Date

//

Approved j

Stathnr1p4agcr

/

/

L l

74-WTM-1322-5 l

.f FASTENER TESTING DATA SHEET'

  • Sample IDf: NPF4-AF Fastener

Description:

3/4"-10 x 5" Bolt, stud, continuously threaded Description of Sample Stock Location: CA 1B 03 05 03 Material Specification as Documented by Licensee Records: ASTM-A-193 Gr B7 Head Marking (Specification and Manufacturer): N B7

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: NOVA Machine Products P.O. Box 30287 Middleburg Heights, OH 44130 Manufacturer: Nova Machine Products Corp.

P. O. Box 30287 Middleburg Heights, Ohio 44130 P.O. #: SNS-123578 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative:

Date

//[

Engineering j d,,

/

t i

Approved

/Hf Date

/ /)

Station ge'r

/

[

74-WTM-1322-6

1 FASTENER TESTING DATA SHEET

  • Sample IDf: NPF4-AH Fastener

Description:

3/4"-10 x 7" Bolt, stud, continuously Description of Sample Stock Location: CA IB 02 06 01 Material Specification as Documented by Licensee Records: ASTM-A-193 Gr B7 Head Marking (Specification and Manufacturer): B7 T

' ** Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressura Boundary Supplier: Hardware Specialty 48-71 36th Street Long Island City, NY-11101 Manufacturer: Texas Bolt Co.

P. O. Box 1211 Houston, TX 77251-1211 P.O. #: NS-34310 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 Licensee Representative:

/

[

Engineering

/

4 _

Date

' Approved

)

[/,Jul Date

/ /((

Statio dger

/- /

74-WTM-1322-8

l i --

' FASTENER TESTING DATA SHEET

  • Sample IDf: NPF4-AI Fastener

Description:

3/4"-10 x 7" Bolt, stud,-continuously threaded Description of Sample. Stock' Location: W5 1A 13 04 01 Material Specification as Documented by Licensee Records: ASTM-A-193-Gr B7 Head Marking (Specification and Manufacturer): C B7

    • Class / Procurement Level: - Safety Related Genera.1 Plant Application.(e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Sales Systems Limited 700 Florida Ave.

Portsmouth, VA 23707 Manufacturer: Cavalier Bolt & Nut 5188 Cleveland St Virginia Beach, VA 23402 P.O. f: NS-13656 QA Requirements Imposed on Vendor: Certificate of Conformance Manufacturer's Certificate of Compliance Licensee Representative:

Engineering

/

/(

/1 Date

/[

J&

,,, rov.d s,a cat.

StatT6n ager

//

74-Wnt-1322-9

FASTENER TESTING DATA SHEET

  • Sample IDI: NPF4-AJ Fastener

Description:

1"-8 x 6" Bolt, stud, continuously threaded Description of Sample Stock Location: WS PR 1E 03 01 02 Material Specification as Documented by Licensee Records: ' ASTM-A-193 Gr B7 Head Marking (Specification and Manufacturer): D B7

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Hardware Specialty 48-71 36th St.

Long Island City, NY 11'.01 Manufacturer: Daniel Industries P. O. Box 292 Houston TX 77001 P.O. #: NS-14028 QA Requirements Imposed on Vendor:

Certificate of Conformance Manufacturer's Certificate of Compliance Licensee Representative:

Engineering d

Date

/[

Approved 46#l!

7 Date St.ti7....r 74-WrM-1322-10

F.GTENER TESTING DATA SHEET

  • Sample IDf: NPP4-AK Fastener

Description:

1 1/8"-8 x 8" Bolt, stud, continuously threaded Description of Sample Stock Location: CA 1C 02 07 01 Material Specification as Documented by Licensee Records: ASTM-A-193 Gr B7 Head Marking (Specification and Manufacturer): J B7 HEE

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Hardware Specialty 48-75 36th Street Long Island City, NY 11101 Manufacturer:

B & G Manufacturing P.O. Box 269 3067 Unionville Pike Hatfield PA 19440 P.O. #: SNS-118402 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Sec. tion III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B i

Licensee Representative:

Engineering j /&

Date

[

t,

/

4'//

Date

/ >[

Approved

(

/

Stat 1T agsr

/ ~ '/

l l

74-WrM-1322-11 1

a

FASTENER TESTING DATA SHEFf

  • Sample IDf: NPF4-AL.

Fastener

Description:

'l 1/4"-8 x 8 " Bolt, stud, continuously threaded Description'of Sample Stock Location: CA 1C 02 05 01 a

Material Specification as Documented by Licensee Records: ASTM-A-193 Gr B7 1~

Head Marking (Specification and Manufacturer): GC 9 N B7

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Hub, Inc.

Energy & Process Division P. O. Box 125 Tucker, GA 33084 Manufseturer: NOVA Machine P. O. Box 30287 Middleburg Heights, OH 44130 P.O. #: NS-31752 QA' Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda througri 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative:

((

Engineering 1,,,

Date Station hv(ger I

/

/

74-WTM-1322-12

4 FASTENER TESTING DATA SHEET

  • Sample IDf:.NPF4-AM Fastener

Description:

1 1/4"-8 x 8" Bolt, stud, continuously threaded Description of Sample Stock.Lo<:ation: CA.1C 02 05 01 Material Specification as Documented by Licensee Records: ASTM-A-193 Gr B7 Head-Marking (Specification and Manufacturer): B7 S

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Sales Systems Limited 700 Florida Avenue Portsmouth VA 23707 Manufacturer: Cavalier Bolt & Nut Inc.

5188 Cleveland St.

Virginia Beach, Va. 23402 P.O. f: NS-11838 QA Requirements T.nposed on Vendor: Certificate of Conformance Certified Material Test Reports Licensee Fet esentative:

Date d

Engineering

/

// M3 7

M/V

~ Station M ger

'/

Date

/

Approved

/

74-WrM-1322-13

FASTENER TESTING DATA SHEET f

  • Sample ID : NPF4-AN Fastener

Description:

1 1/4"-8 x 12' Threaded bar Description of Sample Stock Location:- W5 MR 02 11 Material Specification as Documented by Licensee Records: ASTM-A-193 Gr B7 Head Marking (Specification and Manufacturer): N B7

    • Class / Procurement Level: - Safety Related General Plant App 1tcation (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: NOVA Machine Products P. O. Box 30287 Middleburg Heights, OH 44130 Manufacturer: Nova Machine Products P.O. Box 30287 Middleburg Heights, OH 44130 P.O. #: NS-34073 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative

/[

4A, Date 1

Engineering Jrer A,, rov.d

,a cat.

Stat Y ger

/

/

p 74-WrM-1322-14

FASTENER TESTING DATA SHEET

  • Sample'IDf: NPF4-A0 Fastener

Description:

1/2"-20 x 12' Threaded bar Description.of Sample Stock Location: W5 MR 02 04 Material Specification as Documented by Licensee Records: ASTM-A-193 Gr B8M Head Marking (Specification and Manuf acturer): No Markings

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Hub Inc.

P.O. Box 125 Tucker, GA 30084

-Manufacturer: NOVA Machine Products P.O. Box 30287 Middleburg Heights, OH 44130 P.O. #: NS-30900 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative:

,/[

Engineering

[ /S M Date Approved

/4n([

Date

/ /3 7 tati ger" '

/

/

74-WTM-1322-15

,.(

FASTENER TESTING DATA SHEET

  • Sample IDf: 'NPF4-AP Fastener

Description:

5/8"-11 x 12' Threaded bar Description of Sample Stock Location: W5 MR-02 09 Material Specification as Documented by Licensee Records: ASTM-A-193 Gr B8M Head Marking (Specification and Manufacturer): No Markings

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Tidewater Industrial Fasteners Corp.

2427 Ingleside Road Norfolk, VA 2 23513 Manufacturer: Cavalier Bolt & Nut 5188 Cleveland St.

Virginia Beach, VA 23402 P.O. #: NS 30397 QA Requirements Imposed on Vendor: Certificate of Conformance Manufacturer's Certificate of Compliance 10CFR50, Appendix B Licensee Representative:

Engineering z'f Date

/[

Approved

/JV Date

// ) [

m Stat W tiger

/

/

74-WrM-1322-16

l Tm n TESTING DATA SREET

  • Sample IDf: NPF4-AQ Fastener

Description:

1"-8 x 12' Threaded bar Description of Sample Stock Location: W5 MR 02 10 Material Specification as Documented by Licensee Records: ASTM-A-193 Gr B8M Head Marking (Specification and Manuf acturer):

N B8M GD1

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Energy Steel & Supply Rochester, MI c/o P. O. Box 1333 Hendersonville, TN 37075 Manufacturer: NOVA Machine Products P. O. Box 30287 Middleburg Heights, OH 44130 P.O. #: NS-32350 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative:

((

Engineering

[

/

4, Date I 4s' dw A,, - e,

..t.

~ Sta M ag'e r'

'/

74-WM-1322-17

V FASTENER TESTING DATA SHEET

  • Sample IDf: NPF4-AR Fastener

Description:

.5/8-11 x 12' Threaded Bar

~

Description of Sample Stock Location: W5 MR 01 19 Material Specification as Documented by Licensee Records: ASTM-A-193 Cr B16 Head Marking (Specification and Manufacturer): No Markings

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Hardware Specialty 48-71 36th Street Long Island City, NY 11101 Manufacturer: A & G Engineering 4640 E. La Palma Ave.

Anaheim, CA P.O. #: NS-31026 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative:

//[ [

/

/ /f ///-

Date Engineering

~

11/

iker A,,r..d vate "4

//

" Statio r

74-WrM-1322-18

n FASTENER TESTING DATA SHEET ~

  • Sample IDf: NPF4-AS Fastener

Description:

3/4"-10 x 12' Threaded bar' Description of Sample Stock Location: W5 MR 01 18

-Material Specification as Documented by Licensee Records: ASTM-A-193 Gr B16 Head Marking (Specification and Manufacturer): No Markings

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Hardware Specialty-48-71 36th Street Long Island City, NY 11101

~

Manufacturer: A & G Engineering 4640 E. La Palma Ave.

Anaheim, CA

- P.O. #: NS-31035 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative:

Engineering d

4A Date

./ N Approved wf/

Date

/ /J [

Station ger

/

I 74-WTM-1322-19 1

(

FASTENER TESTING DATA SHEET

  • Sample ID#: NPF4-AT

' Fastener

Description:

1/2"-13 x 2". Bolt, hex head Description of Sample Stock Location:CA 1C 02 09 04 Material Specification as Documented by Licensee Records: ASTM-A-325 Type 1 Head Marking (Specification and Manufacturer): BIS A325

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Structural Supplier: Hardware Specialty Co., Inc.

48-75 36th Street Long Island City, NY 11101 Manufacturer: Bethlehem Steel Corporation Lebanon Plant P.O. #:

SNS-140270 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative:

Engineering

/

/r//- 4 Date

/

4fA Date

)[

Approved "3t a ~

e'r "7

/

74-WTM-1322-20

L Yj ty:

I 's FASTENER TESTING DATA SHEET

'

  • Sample IDf: N?F4-AU.

Fastener

Description:

1/2"-13 x 3" Bolt, hex head 1

Description of-Sample Stock Location: CA IC 03 01 01 Material Specification as Documented by Licensee Records:. ASTM-A325 Type 1 Head Marking.(Specification and Manufacturer):

BIS A325

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Structural Supplier: Hardware Specialty 48-75 36th Street Long Island City, NY 11101 M2nufacturer: Bethlehem Steel Corp.

Industrial Fastener Division Lebanon Plant P.O. #: SNS-136338 QA-Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representativo:

/[ [

Engineering

/ [

Date

/

/

jd[

Date

/ /3

[

Approved v

nager

/

/

Station i

74-WTM-1322-21

FASTENER TESTING DATA SHEET

  • Sample ID#: NPF4-AV Fastener

Description:

5/8"-11 x 3" Bolt, hex head Description of Sample Stock Location: CA 1C 03 02 04 Material Specification as Documented by Licensee Records: ASTM-A-325 Type 1 Head Marking (Specification and Manufacturer): BIS A325

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Structural i

Supplier: Hardware Specialty 48-71 36th Street.

Long Island City, NY 11101 Manufacturer: Bethlehem Steel Corporation Industrial Fastener Division l

Lebanon Plant P.O. #: NS-34309 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section'III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B l

Licensee Representative:

Engineering d

Date,

Approved 89//

Date

/

[

" Statio d1Tagir

/

/

i l

I 74-WTM-1322-22 1

FASTENElt TESTING DATA SHEET

  • Sample '-IDf : NPF4-AW

' Fastener

Description:

3/4"-10 x 3'1/2" Bolt, hex h'ead Description of. Sample Stock Location:

CA IC 03.01 03 Material Specification as' Documented by Licensee Records: ASTM-A325 Type 1 sA325\\

Head Marking (Specification and Manufacturer):

=t/

    • Class / Procurement Level: - Safety Related General Plant Application _(e.g., Pressure Boundary, Structural)

Structural

' Supplier: Hub Inc.

P. O. Box 125 Tucker, GA 33084 Manufacturer: Cardinal Industrial Products 3873 West Oquendo Las Vegas, Nevada 89118-3098 P.O. #: NS-32569 QA Requirements Impoced on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME

.Section III'in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensec Representative:

Engineering

//-

Date M //

Date

/ /[ [

Approved

' Statio

'aler

~

/

/

/

74-WTM 1322-23

..\\

FASTENER TESTING DATA SHEET

  • Sample ID#: NPF4-AX Fastener

Description:

1/2"-13 Nut, hex 304 SS, semi-tinished Description of Sample Stock Location: CA 1B 01 02 02 f

[

Material Specification as Documented by Licensee Records: ASTM-A-194 Gr 8 I

l Head Marking (Specification and Manufacturer): T8 l

l

    • Class / Procurement Level: - Safety Related l

General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Hardware Specialty Co., Inc.

l 48-75 36th Street Long Island City, NY 11101 l

Manufacturer: Texas Bolt Company P. O. Box 1211 Houston TX 77251-1211 P.O. #: SNS-128586 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative:

Engineering

/

I/ $/_

Date

/

((

, _Affl[

Date _ /

Approved Statir trager

/

74-WTM-1322-24

FASTENER TESTING DATA SHEET

  • Sample IDf: NPF4-AY Fastener

Description:

1/2"-13 Nut, hex 304 SS, semi-finished Description of Sample Stock Location: CA 1B 01 02 02 Material Specification as Documented by Licensee Records: ASTM-A-194 Gr 8 Head Marking (Specification and Manufacturer): T 8

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Hardware Specialty 48-75 36th Street Long Island City, NY 11101 Manufacturer: Texas Bolt P. O. Box 1211 Houston, TX 77251-1211 P.O. #: SNS-147796 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative:

Engineering

/

/

I-Date

/[

4///

Date

/O Approved

/

/

~ Stat r

'ager 74-WIM-1322-25

FASTENER TESTING DATA SHEET

'* Sample IDf: NPF4-AZ Fastener

Description:

1/2"-13 Nut, hex, semi-finished heavy series Description of Sample Stock Location: CA 1H 01 07.05 Material Specification as Documented by Licensee Records: ASTM-A-194 Gr 2H Head Marking (Specification and Manufacturer):

2HT

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Hardware Specialties Co. Inc.

48-75 36th Street Long Island City NY 11101 Manufacturer: Texas Bolt Company P. O. Box 1211 Houston, TX 77251-1211 P.O. f: SNS-145772 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative:

/,/

Engineering

/

8/

Date Approved

//////

Date

/

[

~ Sta W

'ager

/

/

74-WTM-1322-26

FASTENER TESTING DATA SHEET

  • Sample IDf: NPF4-BA Fastener

Description:

1/2"-13 Nut, hex semi-finished heavy series Description of Sample Stock Location: W5 1A 13 03 01 Material Specification as Documented by Licensee Records: ASTM-A-194 Gr 2H Head Marking (Specification and Manufacturer):

J S 2H

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Sales Systems LTD 700 Florida Ave.

Portsmouth, VA 23707 Manufacturer: Cavalier Bolt & Nut 5188 Cleveland St.

Virginia Beach, VA 23420 P.O. #: NS-13656 QA Requirements Imposed on Vendor: Certificate of Conformance Manufacturer's Certificate of Compliance Licensee Representative:

//[ [

Engineering

/ 244-Date 1

Approved

_ d s/l Date

/ )

Station 7 gr

/

/

l l

74-WTM-1322-27

FASTENER TESTING DATA SHEET

  • Sample ~IDI: NPF4-BB m

Fastener

Description:

1/2"-20 Nut, hex, finished Description of Sample. Stock Location: CA IB 01 02 04 Material Specificatien as Documented by Licensee Records: ASTM-A-194 Gr 2H Head Marking (Specification and Manufacturer): Y 2H

    • Class / Procurement Level: - Safety Related' General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier:

Sales Systems LTD 700 Florida Ave.

Portsmouth, VA 23707 Manufacturer: Cavalier Bolt & Nut 5188 Cleveland St.

Virginia Beach, VA 23420 P.O. #: NS-08612 QA Requirements Imposed on Vendor: Certificate of Conformance Licensee Representative:

Engineering

/! /d / /u

.[Y Date e,/

Jn/r A,, rov.d Dat.

Station Ra er

/

/

74-WTM-1322-28

FASTENER TESTING DATA SHEET

  • Sample IDf: NPF4-PC:

c Fastener

Description:

5/8"-11 Nut, hex, 316 SS Description of Sample Stock Locatiosa CA 1B 01 08 03 Material Specification as Documented by Licensee Records: ASTM-A-194 Gr 8M Head Marking (Specification and Manuf acturer): T 8 M

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: NOVA Machine Products P. O. Box 30287 Middleburg Heights, OH 44130 Manufacturer: Texas Bolt Company P. O. Box 1211 Houston, TX 77251-1211 P.O. #:

SNS-143481 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115). or later edition of ASME Sectioa III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative:

Engineering

/

/f 6 Date

/[

' as/

Arbe vat.

A,,ro,ed

" Stat 1E figier

//

74-WTM-1322-29

~

'ftc

~

u-FASTENER TESTING DATA SHEET 3

  • Sample IDf: NPF4-BD-Fastener

Description:

5/8"-11 Nut, hex, 316 SS

' Description of Sample Stock Location: CA IB 01 08 03 Material Specification as Documented by Licensee Records: ASTM-A-194 Gr 8M Head Marking (Specification and Manufacturer): N 8MB

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Hub Inc.

P. O. Box 125 Tucker, GA 33084 Manufacturer: NOVA Machine Products P. O. Box 30287 Middleburg Heights, OH 44130 P.O. f: NS-34373 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including coda cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B

' Licensee Representative:

Enginee. ring

/ [

/-

Date

//[

o

)

/

/

Approved flg Date

/ /

d

/

/

Stationpm6agdt

i 74-WTM-1322-30

-FASTENER )ESTING DATA SHEET

  • Sample IDf: -NPF4-BE Fastener

Description:

5/8"-11 Nut, hex, semi-finished heavy series Description of Sample Stock Location: CA IB 01 05 Material Specification as Documented by Licensee Records: ASTM-A-194 Cr 2H Head Marking (Specification and Manufacturer):

2 H T

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: NOVA Machine Products P. O. Box 30287 Middleburg Heights, OH 44130 Manufacturer: Texas Bolt P. O. Box 1211 l

Houston, TX 77251-1211 P.O. #: SNS-123578 l

QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addends through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B l

Licensee Representative:

Engineering

/ [

/p Date

[

Approved fdt/

Date

//

Station Ifger

/

/

74-kTM-1322-31

FASTENER TESTING DATA SHEET

  • Sample IDf: NPF4-BF

. Fastener

Description:

3/4"-10 Nut, hex, semi-finished heavy series Description of Sample Stock Location: CA 1A 02 0102 Material Specification as Documented by Licensee Records: ASTM-A-194 Gr 2H Head Marking (Specification and Manuf acturer): J S 2H

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Hardware Specialty 48-75 36th Street Long Island City, NY 11101 Manufacturer: BV V/h JOH SMIT P.O. #: SNS-141463 QA Requirements Imposed on Vendor: ANSI B31.7, 1969-Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME l

Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative:

/ /-f k Engineering

/

d Date l

c

///

Approved

. /4/M Date

/

/

Station ger 1

l l

l 74-kTM-1322-32 l

FASTENER TESTI1VJ DATA SHEET

  • Sample IDf: NPF4-BG Fastener

Description:

3/4"~10 Nut, heavy hex Description of Sample Stock Location: W5 PR 2M 05 04 02 Material Specification as Documented by Licensee Records: ASTM-A-194 Cr 2H Head Marking (Specification and Manufacturer):

2 HT

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: NOVA Machine Products P. O. Box 30287 Middleburg Heights, OH 44130 Manufacturer: Texas Bol.t Company P. O. Box 1211 Houston, TX 77251-1211 P.O. f: NS-125754 I

QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through l

19'/0 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section EII in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B l

l Licensee Representative:

// 8 Engineering

/[M/ 6 Date Approved

(

  1. 1/

/

Date

-[

l Station g'er

/

/

l l

l l

74-WrM-1322-33

j FASTENER TESTING DATA SHErr

  • Sample IDf: NPF4-BH-Fastener bescription:

1"-8 Nut, heavy hex, semi-finished

. Description of Sample Stock Locatien: CA 1B 01 07 02 Material Specification as Documented by Licensee Records: ASTM-A-194 Gr 8

' Head Marking (Specificatic'n and Manufacturer): T 8 CPW

    • Cless/Procurecent Level: - Safety Related GeneTal Plant Application (e.g., Pressute Boundary, Structural)

Pressure Boundary Supplier: Hardware Specialty

'48-71 36th Street Long Island City, NY 11101 Manufacturer: Texas Bolt P. O. Box 1211 Houston, TX 77251-1211 P.O. #: NS-32896 QA Requirements Imposed on Vendo*;: AFSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, F,1, 83R, and 115), or later editien of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B l

Licensee Representative:

Engineering

[/, [

[

Date

/

v-e 6//(([

Date

/ /

Approved Weati6n

/ /

74-WTM-1322-34

FAST 10lER TESTING DATA SHEET

  • Sample TDf: 'NPF4-BI l'

Fastener

Description:

1"-8 Nut, hex, semi-finished heavy series Description of Sample Stock' Location: CA 1A 02 08 Material Specification as Documented by Licensee Records: ASTM-A-194 Gr 2H

'N Head Marking (Specification and Manuf acturer):

DH 2H A8 CD

(

/

    • Class / Procurement Level: - Safaty Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Hub Inc.

P. O. Box 125 Tucker, GA 33084 Manufacturer: Cardinal Industrial Prod.

3873 West Oquendo Las Vegas, Nevada 89118-3063 P.O. #: NS-31810 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative:

Engineering

[4 6

Date

((

J' n,,s hdre

,at.

A,,r.v.d

~

/

" S th ger

/

/

74-WTM-1322-35

)

FASTENER TESTING DATA SHEET

  • Sample ID#: NPF4-BJ Fastener

Description:

1 1/8"-8 Nut, hex, super temp heat treated Description of Sample Stock Location:- CA 1A 02 03 01 Material Specification as Documented by Licensee Records: ASTM-A-194 Gr 2H Head. Marking (Specification and Manuf acturer):

7 P N67 T

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Hardware Specialties Co., Inc.

48-72 36th Street Long Island City, NY 11101 Manufacturer: A & G Engineering Co. II, Inc.

4640 E. La Palma Ave.

Anaheim, CA P.O. #: NS-31335 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative Engineering

[,

Date 6,e s ce A,, -.d

..t.

Stati W er

//

74-VrM-1322-36

y FASTENER TESTING DATA. SHEET-0,

  • Sample IDI:.NPF4-BK Fastener

Description:

1 1/4"-8 Nut, hex,-steel Description of' Sample Stock Location: W5 PR 2M 05 04 01 Material Specification as Documented by Licens6e Records: ASTM-A-194 Gr 7 Head Marking -(Specification and Manufacturer): PNGS 7T

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: NOVA Machine Products P. O. Box 30287 Middleburg Heights, OH 44130 Manufacturer: Texas Bolt Company P. O. Box 1211 Houston, TX 77251-1211 P.O. #: SNS-123578 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases'78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative:

(( [

Engineering M

d-Date Approved f81//

Date

/

l y.r stacon l

74-WTM-1322-37

FASTENER TESTING DATA SREET

  • Sample IDf: NPF4-BL Fastener

Description:

1 3/4"-8 Nut, hex heavy

~

Description of Sample Stock Location: CA 1A-02 07 04

' Material Specification as Documented by Licensee Records: ASTM-A-194 Gr 2H Head Marking (Specification and Manufacturer):

2H 6 1.3/4"

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Tidewater Industrial Fasteners 2427 Ingleside Road Norfolk, VA 23513 Manufacturer: Cavalier Bolt & Nut 5188 Cleveland St.

Virginia Beach, VA 23420 P.O. #: NS-13590 QA Requirements Imposed on Vendor: Certificate of Conformance Certified Material Test Report Licensee Representative:

Engineering d.--

Date

[N Approved

< ft/

Date

/

3 Station tier

/

/

74-VrM-1322-38

FAST 1DIER TESTING DATA SHEET,

  • Sample IDf:..NPF4-BM

. Fastener

Description:

1 3/4"-8 Nut, hex, heavy Description-of Sample Stock Location: CA 1A 02 07 04 Material Specification as Documented by Licensee Records: ASTM-A-194 G1 2H Head Marking (Specification and Manufacturer):

05176 3 2H

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Sales Systems, Ltd.

700 Florida Ave.

Portsmouth, VA 23707 Manufacturer: Cavalier Bolt & Nut 5188 Cleveland St.

Virginia Beach, VA 23420 P.O. f: NS-1074' QA Requirements Impond on Vendor: Certificate of Conformance Certified Material Test Reports Licensee Representative:

Engineering

/

k, Date Approved

/

_ /dW[

Date

/

/I Stati Gnager

/'

/

74-WTri-1322-39

~

FASTEllER TESTING DATA SHEET' f':.;

. Sample IDf: NPF4-BN Fastener

Description:

1 3/8"-8 Nut, hex, heavy Description of Sample St'ock Location: CA 1A 02 04 01 Material Specification as Documented by Licensee Records: ASTM-A-194 Gr 7 Head Marking (Specification and Manufacturer): PS33 7T

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Hardware Specialty 48-75 36th Street Long Island City, NY 11101 Manufacturer: Texas Bolt P. O. Box 1211 Houston, TX 77251-1211 P.O. f: SNS-140279 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code. cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative:

Date

/

[

Engineering

/

I,,

Approved fis//

Date

/

'd

[

Mt

'ager

/

/

74-WrM-1322-40

FASTENER TESTING DATA SHEET

  • Sample IDf: NPF4-B0 Fastener

Description:

1 3/8"-8 Nut, hex, heavy semi-finished Description of Sample Stock Location:

CA 1A 02 07 01 Material Specification as Documented by Licensee Records: ASTM-A-194 Gr 7 Head Marking (Specification and Manufacturer): PSS 7T

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Hardware Specialty 48-75 36th Street Long Island City, NY 11101 Manufacturer: Texas Bolt P. O. Box 1211 Houston, TX 77251-1211 P.O. #: NS-34310 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative:

Engineering

/

M

[

Date

/

Approved f5u/

Date

/ /\\

StatD er

~

/

/

l l

74-WrM-1322-41 l

= _ _ _. _ _ _ _ _ _ -.

FASTENER TESTING DATA SHEET

  • Sample IDf: NPF4-BP Fastener

Description:

1 3/8"-8 Nut, hex, carbon steel Description of Sample Stock Location: CA 1A 04 01 04 Material Specification as Documented by Licensee Records: ASTM-A-194 Gr 2H Head Marking (Specification and Manufacturer):

B4YO99 2H

    • Class / Procurement Level: - Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: Tidewater Industrial Fasteners 2427 Ingleside Road Norfolk VA 23513 Manufacturer: Cavalier Bolt & Nut 5188 Cleveland St.

Virginia Beach, VA 23402 P.O. #: NS-13590 QA Requirements Imposed on Vendor:

Certificate of Conformance Certified Material Test Report Licensee Representative:

Engineering

/

f Date

//[ [

/

Approved M//

Date

/ //

' Station gEr

/

/

74-WrH-1322-42 a

FASTENER TESTING DATA SHErr

  • Sample IDi: NPF4-BQ Fastener

Description:

7/8"-9 Nut, hex, semi-finished heavy series Description of Sample Stock Location: CA 1A 02 0103 Material Specification as Documented by Licensee Records: ASTM-A-194 Gr 2H Head Marking (Specification and Manufacturer): D 2H

    • Class / Procurement Level: - Safety Related General Plant Applicatioti (e.g., Pressure Boundary, Structural)

Pressure Boundary Supplier: NOVA Machine Products P. O. Box 30287 Middleburg Heights, OH 44130 Fbnufacturer: Precision Nuclear Products 2105 Donley Drive Suite 104 Austin TX 76758 P.O. #:

SNS-123578 QA Requirements Imposed on Vendor: ANSI B31.7, 1969 Ed. with addenda through 1970 (including code cases 78, 81, 83R, and 115), or later edition of ASME Section III in accordance with Class 1.

10CFR21 and 10CFR50, Appendix B Licensee Representative:

Date

((

Engineering

/

s 24r

. tat.y.,/s cat.

A,,r.v.d r

74-WTM-1322-43 l

l

ATTACHMENT 2 NRC ENFORCEMENT BULLETIN 87-02 DATA

SUMMARY

NORT2 ANNA POWER STATION Tablo Page 1 D:ta 11-Jan-88 Rockwell Hardness Average Min. of 2 neasurements Tensile Properties

% Reduc-Chemical Analysis Post Heat Ultimate Yield Etong-tion of ID No.

Initial Treatment (Kst)

(Ksi) ation Area C

Mn P

S Si Cr Ni Mo V

ASTM A-193 Gr BT Standard N/A N/A 125 105 16 min

.37 49.65-1.10.035 max.040 max 0.15-0.35.75-1.20 N/A.15.25 N/A NPF4-A8*

N/A N/A 151 142

  • 12 58 0.40 1.00 0.026 0.024 0.24 1.01 0.20 NPF4-AC*

N/A N/A 149 138

  • 15 64 0.42 0.93 0.021 0.023 0.22 1.01 0.21 NPF4-AD N/A N/A 149 144 16 56 0.40 0.99 0.023 0.023 0.22 1.04 0.21 NPF4-AE*

N/A N/A 152 137

  • 12 57 0.40 1.00 0.020 0.021 0.23 1.05 0.21 NPF4-AF N/A N/A 147 138 19 58 0.40 0.99 0.024 0.020 0.25 1.02 0.20 NPF4-AN N/A N/A 157 144 17 54 0.42 0.90 0.023 0.019 0.25 0.99 0.20 NPF4-Al N/A N/A 131 112 22 59 0.41 1.00 0.021 0.023 0.29 1.03 0.20 NPF4-AJ N/A N/A 138 119 18 64 0.41 0.90 0.016 0.015 0.23 0.86 0.21 NPF4-AK N/A N/A 139 120 18 59 0.40 0.96 0.024 0.021 0.28 1.03 0.22 MPF4-AL N/A N/A 144 126 18 59 0.41 0.99 0.020 0.024 0.22 0.97 0.21 NPF4-AM N/A N/A 139 123 19 55 0.42 0.92 0.019 0.020 0.26 1.03 0.20 NPF4-AN N/A N/A 147 131 19 61 0.41 0.99 0.025 0.021 0.23 0.92 0.21 ASTM A-193 816 Standard N/A N/A 125 105 18 min

.36.37 45.70.035 max.040 max

.15.35.80-1.15 N/A.50.65.25.35 NPF4-AR*

N/A N/A 129 118

  • 16 63 0.40 0.63 0.022 0.017 0.23 0.90 0.505 0.275 NPF4-AS*

N/A N/A

  • 123 115 22 67 0.41 0.62 0.016 0.015 0.27 0.84 0.511 0.259 ASTM A-325 Type 1 ; Product Analysis Chemistry Ranges)

Stand. 24-35 Rc 120 N/A

.27 min

.47 min.048 max.058 max N/A N/A N/A N/A N/A l

NPF4-AT 35 Rc N/A 168 0.42 0.96 0.020 0.022 l

NPF4-AU 31 Rc N/A 149 0.41 0.80 0.027 0.026 l

NPF4-AV 33 Rc N/A 148 0.33 0.77 0.019 0.017

(

NPF4-AW 31 Rc N/A 151 0.32 0.72 0.022 0.011 ASTM A-193 Gr B3M, (class 1)

Stand.

96tb max N/A 75 30 30 min 50 min

.08 max 2.0 max.045 max.030 max 1.00 max 16.0-18.0 10.0-14.0 2.0-3.0 N/A NPF4-AO* *100 Rb N/A 111 88.0

  • 24 68 0.07 1.58 0.009 0.022 0.35 16.39 10.3 2.3 NPF4-AP* *105 Rb N/A 134 104
  • 16 59 0.07 1.69 0.012 0.022 0.52 17.04 11.8 2.1 EPF4-AQ 85 Rb N/A 91.0 47.4 48 73 0.07 1.56 0.010 0.016 0.44 17.56 11.0 2.1 ASTM A-194 Gr 8 Stand.60-105 Rb N/A N/A N/A

.08 max 2.00 max.045 max.050 max 1.00 max 18.0-20.0 8.0-10.5 N/A N/A NPF4-AX 74 Rb N/A N/A N/A N/A N/A 0.07 1.06 0.011 0.010 0.56 18.6 9.4 NPF4-AY 71 Rb N/A N/A N/A N/A N/A 0.07 1.06 0.016 0.014 0.58 18.4 9.2 NPF4-BM 88 Rb N/A N/A N/A N/A N/A 0.08 1.26 0.009 0.006 0.59 18.5 8.6 ASTM A-194 Gr 2M Stand. 24-38 Rc 89 Rb min N/A N/A

.40 min N/A.040 max.050 max N/A N/A N/A N/A N/A

(

NPF4-AZ 30 Rc 23 Rc N/A N/A N/A N/A 0.41 0.025 0.017 i

1 l

c2 c:e.. n

r NORT: ANNA POWER STATION Table Page 2 Date 11-Jan-88 Rockwelt Nardwss Average Min. of 2 Measurements Tensite Properties

% Reduc-Chemical Analysis Post Heat Ultimate Yield Etong-tion of ID No.

Initlet Treatment (Ksi)

(Kal). ation Area C

Mn P

S Si Cr Ni Mo V

NPF4-BA 31 ac 27 ac N/A N/A N/A N/A 0.40 0.025 0.022 NPF4-BB 28 Rc 24 Rc N/A N/A N/A N/A 0.44 0.019 0.023 NPF4 BE 34 Rc 27 Rc N/A N/A N/A N/A 0.44 0.029 0.024 NPF4-SF 28 Rc 27 Rc N/A N/A N/A N/A 0.46 0.031 0.035 NPF4-BG 33 Rc 23 Rc N/A N/A N/A N/A 0.44 0.028 0.022 MPF4-SI 29 Rc 23 Rc N/A N/A N/A N/A 0.44 0.027 0.025 NPF4-BJ 26 Re 26 Rc N/A N/A N/A N/A 0.43 0.024 0.020 MPF4-BL 27 Rc 25 ac N/A N/A N/A N/A 0.46 0.023 0.027 NPF4-BM 27 Rc 22 Rc N/A N/A N/A N/A 0.47 0.028 0.023 NPF4-SP 29 Rc 23 Rc N/A N/A N/A N/A 0.45 0.023 0.028 NPF4-De 26 ac 22 Ac N/A N/A N/A N/A 0.42 0.020 0.027 ASTM A-194 Gr 7 Stand. 24-38 Rc 96 Rb min N/A N/A

.37.49.65-1.10.04 max.04 max

.15.35.75-1.20 N/A.15.25 N/A NPF4-BK 33 ac 26 Rc N/A N/A N/A N/A 0.39 0.80 0.02 0.02 0.31 0.80 0.21 NPF4-BN 30 ac 98 Rb N/A N/A N/A N/A 0.38 0.78 0.02 0.02 0.26 0.75 0.20 NPF4-90 29 ac 21 Rc N/A N/A N/A N/A 0.40 0.87 0.03 0.02 0.26 0.84 0.21 ASTM A-194 Gr 8M Stand.60-105 Rb N/A N/A N/A

.08 max 2.00 max.045 max.030 max 1.00 max 16.0-18.0 10.0-14.0 2.0-3.0 N/A e

NPF4-BC 85 Rb N/A N/A N/A N/A N/A 0.08 1.50 0.009 0.009 0.42 17.0 10.7 2.1 NPF4-B0 95 Rb N/A N/A N/A N/A N/A 0.07 1.34 0.013 0.011 0.50 17.2 11.0 2.2

?8.9

.