v TIME \\
10\\20 AM TWX \\ 64 DATE\\ 5/10/72 '
1972 UAY 10 AM 10 27 U.S. ATOM;C D.TitGY COMM
'U.S.
ATOMIC ENERGY COMMISSION N#
WASHINGTON, D.C.
20545 N
s S
ATTENTION \\
DIVISION OF REACTOR LICENSING gt "h-b f%6 fCh 9
REFERENCE \\
LICENSE NO. DPR-
\\ DOCKET NO. 50-29\\
Co
%\\
'cnI \\W DEAR SIRS \\
A DETAILED REVIEW OF THE ACCIDENTS ASSOCI ATED WITH YANKEE ATOMIC ELECTRIC COMPANY PROPOSED CHANGE NO. 99 REVEALED THAT INCREASING THE MAIN COOLANT SYSTEM BORON CONCENTRATION ABOVE 1700 PPM MIGHT EFFECT THE BORON DILUTION ACCIDENT.
HOWEVER, A REANALYSIS OF THE ACCIDENT AT A MAIM COOLANT SYSTEM BORON CONCENTRATION OF 2000 PPM INDICATES THAT THE INCREASE IN BORON CONCENTRATI'ON HAS NO SIGNIF-ICA.'T EFFECT ON THE RESULTS OF THE ACCIDENT.
UE TRUST THAT THIS ADDITIONAL INFORMATION UILL ASSIST YOU IN 03TAINING PROMPT APPROVAL OF PROPOSED CHANGE NO. 99.
D. E. VANDENBURGH, VICE PRESIDENT YANKEE ATOMIC ELECTRIC COMPANY THIS DOCUMENT CONTAINS POOR QUAUTY PAGES YANKEE WTB0 CCRRECTION\\
REFERENCE \\ LICENSE NO. SHOULD BE DPR-3
~0)MM)
AEC UASHDC RECD OK
[ k![. p m m F f,-
y quv hY,kJ
,I k k,
^
a c.rw. m
~:,,;;w > +
,:.: 4:,;;2 2+. :;, - z wyn
^
1,
~
y
,: 4: -
e ilA seM < I..*
ai ;4M Mm bi 41 \\ ' fi5kSf-8 011050 4,. 4.fhyf 4 lffy
<~
M m
4...
~
p y.
AEC AISTRIBUTION FOR.: PART
- 50. 4 nCKET.. MATERIAL f
Q (CD'20BARY FORMQ W
- 3 CONTROL NO:.
2535
'FRON! Yankee Atomic Elec. Co.
DATE OF DOC:.
DATE REC'D LTR MEMO RPT OTHER Westboro, Mass. 01581
- -.. D F - Un nelenh ut ph 5-10-72 5-10-72 TWX CC Ol'HER SENT AEC PDR.. /
D 1
SENT LOCAL PDR-CLASS: Q/ pro? I;;FO I;;PUT
- 40 CYS REC'D DOCKET NO
1 50-29 DESCRIPTION: TWX furnishing addl into on C;CLOSURZS :
the accidents associated with YAEC Proposed Change'No.
99.,...
i m.
vnn uvpTon DL 5-10-72 EUTLER(DRL)
DICKER (DREP)
(SCEDIEL(DRL)
ZIEMANN(DRL)
W/ Copies W/ Copies W/9 Copies W/ Copies W/ Copics CHITWOOD(DML)'
00LLA(DRL)
SCHWENCER(DRL)
W/ Copies W/ Copies W/ Copics W/ Copies W/ Copics CL\\RK(DRL)
KNIEL(DRL)
STOLZ(DRL)
W/ Copies W/ Copies W/ Copies W/ Copies W/ Copics,
H. DENTON KNIGHTON(DREP)
VASSALLO(DRL)
W/ Copies W/ Copics W/ Copies W/ Copies U/ Copics TT: mVAT. T)TRrPRTtTFFTOM
$Rcr, FiM D Voll:c.or(DRL)
O M. Fitr. patrick (DRF.P) O
O Kastner(DR2?)
O
@ Complianec(2) @
O Lonn(DRL)
QLic. Asst (DR3?)
O O OGC, am P 506A QCollins(DRL)
O McCrcless(D32P)
O
@Muntzing6 Staff
@ Tho::pson (DRL)
O c. cicnc(DRzP)
O D i;orri s /Dubc/Uilson(DRL)
O D. E. i: urn (DRL)
O Project Leader (DR3P) O
.DIorris/Schroeder(DRL)
O Benaroya(DRL)
O DREP File Room O
% Dubc M (DRL)
O E, G. Ccsa(DRS)
D A. Braittan(SLR)
C
$1 C altart.nn(SLR)
U f.I DeYount;(DRL)
O Sec11o(DRS)
C Trenacl(DrP)
O D i!. Denton(DRL)
C V. Moorc(DRS)
O T;iorn ton (xx::)
o f_'jKlechcr(DRL)
O Longc(MIS)
O ;'nu t h (D:lS)
O OCric.eu(DRL){
Q gailey(p;.;L)
O shao (c.;s)
O O Gcmai11(DRL)
O L. nowra(DRcP)
O P.w < e
( ss)
O CTedcSco(ont>>
O Mulicr<Dr:P)
@ su..m e. (r:-
O EXTERNAL DISTRIBUTION 1
- Local PDR i
[1 DTIE(Laughlin)
'dl - NSIC(Buchanan)
)
1p SAN /LA/HY/ PDR y 1 - R. Carroll OC, GT 1 - AEC HQ LIB J-004 1 - ASLB(Yore /Woodard "H" St )
416-HoldingforACBS l-- Chief Water Reactors 2 - Warren Nyer 1 - C. liiles, C-459, GT 1 - R. Catlin, A-170, GT