Submits Results of Review of Three Items in SEP Topic III-6 Re Structural Area,Per Util 870831 Request for Clarification of NRC Position
ML20148F207
Person / Time
Site: Yankee Rowe
Issue date: 09/17/1987
From: Shieh L
LAWRENCE LIVERMORE NATIONAL LABORATORY
To: Cheng T
NRC OFFICE OF SPECIAL PROJECTS
Shared Package
ML20148F173 List:
References
TASK-03-06, TASK-3-6, TASK-RR SM87-109, TAC-51807, NUDOCS 8803280090
Download: ML20148F207 (2)


Text

7 ~'

ATTACHMENT 1

} ff g g

l R

Lawrence Livermore National Laboratory I

m_ J NUCIEAR SYSIDE SAFEI'i PROGRAM September 17, 1987 SM87-109 Dr. 'Ihcznas M. Cheng Office of Special Projects U. S. Nuclear Regulatory himicn Mail Stop EWW-325 4350 E. W. Hwy.

BetW, MD 20814

References:

(1) letter, frm G. Papanic, Jr., Yankee Atcmic Electric Ccmpi.y to Martcn Fairtile, U.S. NRC, dated August 31, 1987.

(2) Lawrence LiverncIe Naticnal Iaboratory, 'Ibtnical Evalmtion Reoort. Stnrtural Desian Issues - Seismic Reevaluaticn of SEP 'Itoic III - 6. Yankee Nuclear Power Station at Rowe, UCID - 21072, dated May 7,1987.

Dear 'Itzn:

I have reviewed the subject letter in which the licensee requested the clarificaticn of staff positico, SEP 'Ibpic III-6, Safety Evaluaticn Report.

Ancrg eleven itms of the licensee's requested clarificaticm, three of the are related to the structural area. 'Iberefore, the results of the review for these three itms are as follows:

SEP Tcoic III-6. Safety Evaluaticn Reoort 1.

Pace 10. Section 4.3.4(1): "Verificaticn of grouting in Inascnry walls where antor bolts and strap anchors were installed."

'Ihe licensee did not agree that it has meitted to verifying the grouting of anchor bolts. After reviewirg the 'Ibtnical Evaluaticn Report (TER) (Ref. 2) and Supplement to the TER, we ocnclu$e that in both reports we did not request the licensee to verify the grmting of the anchor bolts. 'Iherefore, we agree with the licensee's positicn.

2.

Pace 16. Section 4.3.13: "YAEC has crmuitted to perforin the analysis

[ Main Stem /Feedwater) in 1987 and to inpleent any racrhi nodificaticns in 1988."

Scheduling of occpleticn of any task by the licensee is the NRC's jurisdicticn.

3.

Pace 16. Section 4.3.13: "Ib this end, YAEC rymnitted (Reference 41) to subnit the analysis report (for Main Stean/Feedwater] for staff's review when ocupleted."

!!R288a!Si88Sg9 l

P AnEMOwortnn*yE%w*LhwsfydCattma PQDan806LmemcraCaitsru94550 Tekwhone(415)4221100.Twu910 386 8339 UCLLL LW9

1 T.M. Cheng 9/17/87 t

'Ihe licensee disputed this -itment. However, to the best of my

)mowle&pe, it has been URL's position fran the begiming that the licensee was to an* nit the analysis report for Main SteanVFeedwater for staff's review when ompletad. 'Ihat is why we reviewed cnly an cutline of the method of analysis for these two piping systes.

Sinoezuly, L.C. Shieh Project Tswbr Yankee Rcre Saimic Reevaluatico Project Ics SM87-109 cc:

L. C. Ruth Morton Fairtile l

l l

l i

r-w

-w

/

ArTACHMENT 1 3

} 'fy g g R

Lawrence Livermore National Laboratory L_4 NUCEAR SYSTDG SAFEIY HEGRAM Sep W2 17, 1987 SM87-109 Dr. Thcmas M. Cheng Office of Special Projects U. S. Nuclear Regulatory M"icn Mail Stop DM-325 4350 E. W. Hwy.

Bethesda, MD 20814 Referen::es:

(1) letter, frun G. Papanic, Jr., Yankee Atcanic Electric Ctr:pany to 2rtcn Fairtile, U.S. NRC, dated August 31, 1987.

~

~

(2) lawrence Liverrore Naticnal laboratory, Technical Evaluatical Reoort. Structural Desian Issues - Seismic Reevaluaticn of SEP 7toic III - 6. Yankee Nuclear Power Station at Rowe, UCID - 21072, dated May 7,1987.

Dear Ttan:

I have reviewed the subject letter in which the licensee requested the clarificaticn of staff positico, SEP Itpic III-6, Safety Evaluaticn Report.

Ancog eleven itans of the licensee's requested clarificatico, three of them are related to the structural area. 'Iherefore, the Itsults of the review for these three itans are as follows:

SEP 7toic III-6. Safety Evaluaticn Reoort 1.

Pace 10. Sectico 4.3.4(1): "Verificaticn of groutirg in rascnry walls where anchor bolts and strap anchors were installed."

The li nsee did not agree that it has meittad to verifyirq the grouting of anchor bolts. After reviewirg the Tbchnical Evaluaticn Report (TER) (Ref. 2) ard Supplanent to the Tm, we ocrclude that in both reports we did not request the licensee to verify the groutirq of the anchor bolts. Therefore, we agree with the licensee's positico.

2.

Pace 16. Secticn 4.3.13: "YAEC has cxzenitted to perform the analysis (Main SteanVFeedwater) in 1987 ard to implanent any raviM

ncdificaticns in 1988."

Scheduling of cxrpleticn of any task by the licensee is the NRC's jurisdicticn.

3.

Pace 16. Section 4.3.13: '% this end, YAEC ocenitted (Reference 41) to submit the analysis report (for Main SteanVFes3 water] for staff's review when empleted."

O%D M EM Owortsry Enpogv.ltners1yct Cattrw

  • PO Ban B06 Lmrmore Cabtvru 94550
  • TeWone M15)4221100 Tws 910 386-8339 0CLLL LW9

4 3 T.M. Cherx; 2-9/17/87

'Ibe licensee disputad this cammitment. However, to the best of my knowledge, it has been I.INL's positicri frun the beginning that the licensee was to submit the analysis report for Main SteanVFeedwater for staff's zwiew when otspleted. 'Ihat is Wy we reviewed cnly an cutline of the method of analysis for these two piping systes.

Sincersly, L.C. Shieh prurject Tswier Yankee Rowe Saimic Reevaluaticri project Its SMB7-109 oc:

L. C. Ruth Morton Fairtile w-

+

g 1