ML20148E814

From kanterella
Jump to navigation Jump to search
Advises That Rev 1 to Emergency Dose Assessment Model (Edam) Program Document Issued & Available at Plant.Major Changes to Program & Program Documentation Include Addition of Edam Benchmark Section
ML20148E814
Person / Time
Site: Comanche Peak  
Issue date: 01/19/1988
From: Counsil W, Woodlan D
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
TXX-88094, NUDOCS 8801260119
Download: ML20148E814 (1)


Text

..

summemame

==

9 Log i TXX-88094

=

File # 10013

.__=

=

1UELECTRIC January 19, 1988 NNn'".NN",$a U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C.

20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AND 50-446 REVISED EMERGENCY DOSE ASSESSMENT MODEL Gentlemen:

On March 29, 1985, Emergency Dose Assessment Model (EDAM) documentation, Revision 0, was submitted for docketing with the NRC.

Since then the EDAM software has been revised and a new EDAM Program Document (Revision 1) has been issued.

This document is available at the CPSES site.

Major changes to the program and program documentation include:

1) Addition of a "SURVEY DATA" option which allows the operatur to back calculate noble gas and iodine release rates using dose rates and iodine concentration measurements in the field.

This option estimates the'whole body and child thyroid dose rates from these release rates.

2) An EDAM Benchmark section has been added to the documentation.

3)

The program now incorporates child thyroid dose calculation parameters such as child breathing rate and child iodine dose factors instead of infant thyroid dose parameters.

Set up and use of the EDAM system is described in EPP-303, "Micro-Computer Based Emergency Dose Assessment." EDAM is backed up by a manual dose assessment method which is described in procedure EPP-300, "Manual Calculation of Offsite Dose Rates."

The most recent revisions of these procedures have been transmitted to the NRC and are maintained in the CPSES Emergency Planning Procedure Manual.

Very truly yours, W, c,. Q 8801260119 880119 W. G. Coun il ADOCK 050

]45-gDR D. R. Woodlan Supervisor, Docket Licensing c - Ms. Melinda Malloy p

Resident Inspectors, CPSES (3) LB81 m NonkOlntS m Dallas. Texas 73.'01

\\p