- _

g n %.,

UNITED STATES NUCLEAR REGULATORY COMMISSION

]

,,Og i

[

REGION IV..

(-

l o

5 611 RYAN PLAZA DRIVE, SUITE 1000 2

AR LINGTON, TEXAS 76011

./

)

13 OCT 1978

[

y y

Docket No. 99900028/78-02 Tube Te~ns Division of Chemetron Corporation Attn:

Mr. J. L. Seay

- Quality Control Manager 2900 W. Broadway P. O. Box 987 Louisville, Kentucky 40201

~

Gentlemen: '

Thank you for your letter of October 5,1978, in response to our letter dated September 8,1978, with an enclosure. As 'a result I

of our review of your October 5 letter, we have no further questions related to Items 1 through 5 and we will review your corrective'.

action for these items during a future inspection.

However, w'ith regard to Item 6, your proposed corrective action on this item is incomplete.

Themfore, we continue to identify this item as a dev-1 I

iacion from ASME Code requirements until such time as you meet your comitments or receive a response from ASME which relieves you from these ASME Code Section III requirements.

Should you have any questions concerning this letter, we will be pleased to discuss them with you.

Sincerely, t

I l

J t

/

6A21)V l

Vendor Inspection Branch _

l Uldis Potapovs, Chiyf l

1 i

l l

1 L

7811.01ooD e.,

es*

===-)

.