Proposed Tech Specs Re Reactor Coolant Pump Flywheel Insp Program
ML20147F824
Person / Time
Site: Wolf Creek 
Issue date: 03/21/1997
From:
WOLF CREEK NUCLEAR OPERATING CORP.
To:
Shared Package
ML20147F817 List:
References
NUDOCS 9703270235
Download: ML20147F824 (2)


Text

, ~ ~ _

-.. -,. -... ~.... ~

_ - - ~., _ _..

Attachmsnt.IV.to ET 97-0027

' ' PKga 1 of 2 j

i 4

l l

1 l

l i

l 1

l, ATTACHMENT IV PROPOSED TECHNICAL SPECIFICATION CHANGES l

l 1

i i

l s

i 1

i i

d i

9703270235 970321 PDR ADOCK 05000482 P

PDR i

i WOLF CREEK UNIT 1 '

6-18c Amendment No. 80,97,101

Attochment IV to ET 97-0027 Page 2 of 2 l

ADMINISTRATIVE CONTROLS PROCEDURES AND PROGRAMS (Continued) 3.

A surveillance program to ensure that the quantity of radioactivity contained in following outdoor liquid radwaste tenks that are not surrounded by linera, dikes, or walls capable of holding the tanks' contents and that do not have tank overflows and surrounding area drains connected to the liquid radwaste system, is less than the amount that would result in concentrations less than the limits of 10 CFR 20, Appendix B Table 11, Column 2 at the nearest potable water supply and the nearest surface water supply in an UNRESTRICTED AREA,in the event of an uncontrolled release of the tank's contents.

a.

Reactor Makeup Water Storage Tank, b.

Refueling Water Storage Tank, c.

Condensate Storage Tank, and d.

Outside Temporary tanks, excluding demineralizer vessels and the liner being used to solidify radioactive waste.

The provisions of Specifications 4.0.2 and 4.0.3 are applicable to the Explosive Gas and Storage Tank Radioactivity Monitoring Program surveillance frequencies.

b.

Reactor Coolant Pump Flywheel Inspection Program Each reactor coolant pump flywheel shall be inspected per the recommendations of Regulatory Position C.4.b of Rennt*g Guide 1.f 4, Revision 1, dated August,1975]In lieu of Position (C.4.b(if a ld C.4.b(2), conduct a qualified in-place UT examination over l

the volume from the inner bore of the flywheel to the circle of one-half the outer radius or conduct a surface examination (MT and/or PT) of exposed surfaces of the removed flywheels once every ten years coinciding with the Inservice inspection (schedule as required by ASME Section XI.

c.

Containment Tendon Surveillance Program This program provides controls for monitoring tendon performance, including the effectiveness of the tendon corrosion protection medium, to ensure containment structural integrity. The program shallinclude baseline measurements prior to initiai plant operation as well as periodic ;esting thereafter. The Containment Tendon Surveillance Program, and its inspection frequencies and acceptance criteria, shall be in accordance with Wolf Creek Generating Station position on draft Re ision 3 of Regulatory Guide 1.35, dated April (49891979]

The provisions of Specifications 4.0.2 and 4.0.3 are applicable to the Containment Tendon Surveillance Program inspection frequencies.

6.9 REPORTING REQUIREMENTS ROUTINE REPORTS 6.9.1 in addition to the applicable reporting requirements of Title 10 Code of Federal Regulations, the following reports shall be submitted to the Regional Administrator of the NRC Regional Office unless otherwise noted.

WOLF CREEK UNIT 1 6-18c Amendment No. 89,97,101