Forwards Structural Response of Crbrp Scale Models to a Simulated Hypothetical Core Disruptive Accident & Closure Head Capability for Structural Margin Beyond Design Base Loading.
Date released: 06/09/2020 Download: ML20147D956


Closure Head Capability for Structural Margin Beyond Design Base Loading. Results of Tests Indicate That Closure Head Is Capable of W/Standing 661 Mj Structural Margin Beyond Design Base Loads W/Out Structural Failures
ML20147D966
Person / Time
Site: Clinch River
Issue date: 11/30/1978
From: Elder G, Prevenslik T, Todd M
ENERGY, DEPT. OF, CLINCH RIVER BREEDER REACTOR PLANT, WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
References
Download: ML20147D966 (212)
Structural Response of Crbrp Scale Models to a Simulated Hypothetical Core Disruptive Accident. Primary Objective of Tests Was to Verify That Scale Models of Subj Reactor Can W/Stand Loads Resulting from Simulation of Hcda
ML20147D960
Person / Time
Site: Clinch River
Issue date: 10/31/1978
From: Christie A
ENERGY, DEPT. OF, CLINCH RIVER BREEDER REACTOR PLANT
To:
References
Download: ML20147D960 (23)
Forwards Structural Response of Crbrp Scale Models to a Simulated Hypothetical Core Disruptive Accident & Closure Head Capability for Structural Margin Beyond Design Base Loading.
ML20147D953
Person / Time
Site: Clinch River
Issue date: 12/13/1978
From: Copeland R
ENERGY, DEPT. OF, CLINCH RIVER BREEDER REACTOR PLANT
To: BOYD R S
Office of Nuclear Reactor Regulation
References
Download: ML20147D953 (2)