Advises That Reuter-Stokes 880229 Request for License to Export 20 Fission Chambers to Austria for Testing & Ultimately to Canada Acceptable.Applicant Request for Exemption to 15-day Waiting Period Also Approved
ML20147D907
Person / Time
Issue date: 03/01/1988
From: Peterson M
NRC OFFICE OF GOVERNMENTAL & PUBLIC AFFAIRS (GPA)
To:
NRC OFFICE OF GOVERNMENTAL & PUBLIC AFFAIRS (GPA)
Shared Package
ML20147D899 List:
References
NUDOCS 8803040200
Download: ML20147D907 (1)


Text

-

9 e Kt%q'o,,

n UNITED STATES 8

NUCLEAR REGULATORY COMMISSION o

WASHINGTON, D. C. 20555 5

y i

\\,...../

MAR 1 1988 MEMORANDUM FOR:

The Files FROM:

Marvin R. Peterson, Assistant Director for International Security International Programs Office of Governmental and Public Affairs

SUBJECT:

PROPOSED EXP0RT LICENSE XCOM1013 On February 29, 1988, Reuter-Stokes requested a license to export 20 fission chambers to Austria for testing and ultimately to Canada for use in the Darlington Nuclear Power Reactor.

The applicant has requested an exemption to the normal 15-day waiting period due to the short lead time before shipment.

The staff has concluded that the proposed 1(cense meets the requirements of the Atomic Energy Act, as amended, and would not be inimical to the common defense and security of the United States.

In view of the above considerations, the staff issued the license without the normal 15-day waiting period.

J jb

!L ^v Marvin R. Peterson, Assistant Director for International Security International Programs Office of Governmental and Public Affairs 1t l,

8803040200 080301 PDR XPORT

'6-XCOM-1013 PDR

$,E.....

cys

%d;f -

A... a.

~

fl M rs U1 6 ci iO' 14 rU4

~

$ reuter stokes Eciison Park Twinsburg, Ohio 44047 g (D l 3 216/425 3755 Telex 985253 February 29, 1988 VTY-88-29

%).w-i Mr. Neal Moore f

Director, Licensing Office Export / Import and International Safeguards office of International Programs Mail Station WF1/3-!PS US Nuclear Regulatory Commission Washington, DC 205S5 References Reuter-Stokes Register F-2109-D IAEA order for Safeguards Application 20 Fission Chambers RS-P6-0805-134 Dear Heal It was a pleasure to talk with you last Friday.

Attached is correspondence from IAEA requesting We ship 20 fission chambers to Austria for testing before they are installed in the Darlington Reactor in Canada.

These chambers can be shipped t.o canada for use in a reactor under NRC General license llo.26(a).

The special nuclear material contained in these fission chambers can be shipped to Austria under NRC 110.21(a)3.

(Each chamber contains 0.13323gm of U235.

Enrichment is approximately 93%.)

Please verify that Router-Stokes may ship these to IAEA in Austria for testing only, from there to be shipped to and installed in the Darlington

Reactor, Newcastle
Township, Ontario, Canada.

I will look forward to your reply.

d 2 :2 sincerely yours, g

]

.~

~

a fW i

Virginia T. Young G

Export Control Coordinator Q

~'

/ 23, M' 0 0 vTv/gm Attachments

A..

1y 73

~

~

, ri t1 n UA

  • y,*

INTERN ATION AL ATOMIC ENERGY ACBNCY AGENCE INTERNATION ALE DE L'ENERGIE ATOMlQUE ME*AYH AP0HHOE ATEHTCTBO [10 ATOMHOR 3HEPTHH ORGANISMO INTERNACIONAL DE ENERGIA ATOMICA WAGRAMERsTRASSE 5, P.O. BOX 100. A 1400 VIENNA. AU$TRIA TELEX: 111645, CABLE INATOM YLENNA. FACSIMILE: 43 222 230184, TELEPMoND (222)236o E*YM170 IEIlll@Editlinme AK / 87 / ThM / gs Mr.Th.Montijn 1987-12-10 f.S2/2/ k[$l f q.to4*O A

1.i Oear Sirs,

Subject:

Purchase Order IAEA 88CL-g Please find attached above mentioned subject purchase order.

It is kindly requested that the shipment be forwarded by air addressed as follows:

Mr. A. Kocian Head, Procura, ment Services Section International Atomic Energy Agancy Vienna International Centre (VIC)

Wagramerstrasse 5 / P.O. Box 100 A-1400 Vienna. Austria.

i Please note that no insurance is required. All shipping documents must show our purchase order number.

Yours f aithfully

~. - - - - -

l A. Kocian Head Procurement Services Section g

Attachment m

~~~J N.

Reuter Stokes

-)..

.m Edison Park Twinsburg if OHIO 44087 USA

.nmn vi 1.

YUn

'14'S7 D819' NC. M

~ N/@

INTERNATIONAL ATOMIC ENERGY AGENCY (IAEA) g.

vf AGR AMERSTR ASSE 5, P.O. BOX 100, A 1400 VIENN A ( AUSTRI 431312/23M TEL(X.112646/113691 ATOW A P ACSIMlkE No. 43

,; J TELtPHONE IAEA MESSAGE

{4 T.O 0.

P AG ES:

M 216-42 54045 m,

y T0; RI Wi.R-SIClGS j

EDISON %V TWINS 11JRO, ORIO t.4067

f. h / $ f-M

&L

/06/66

' FILE REF. 412.R2.0 M (A.135) l m-l s

l

@2.M3.RRLINGTO.

I L sn USS ela FISSION citAnERS CN OUR P.O. M801 1039 E

IN E'tECf0R ASSEMEIES TO E INSTALLED IN !NCLEAR P0hER P END UER IS THE INTERNATIONAL ATCP.IC DiERGY lINCANADA.

{ h?. 'rOULD APPPEIATE ANY 2 CREASE IN 2 LIVE 0 W IT IS TSIAID TO INSTALL THD( IN MARCH OF 1988. TESTIN

{ ITSOT.

f

', SECULD PRECESD INSTALLATION.

I IMANK YOU WR YOUR C0CPERATION.

I INATOM VII:NFA HALBIG j

as c.o

-l 5

Q

=

g

'W in D

E 1

i I

u

.s

~

e*6 6.--

~. -

y

_ _,.,.---,-,--__,.-.~,,,.,,.,.,._.-.-

,, n r.

._1

..1 r- ' ' 4' e

I g,

Enginooring Data Sheet 9.29

-u i

RS-P6-0805-154 Ii R..ssion Counter

=..

^

For neutron counting in a high gamma flux The AS P0-O%5134Isa fissioncounterforuseina I

mixed neutron and gamma flux.

It has special advantages in applications where the detector must operate while exDosed to high gamma flux (>108/R/hr), in such cases, the very

~

large fission pulses permit discrimination against gamma pu!ses and pulse plie up because of the high neutron to gamma s!gnalratjo. B 10and BF,countors would expehence gamma pulse pile up to the extent that they cannot oo operated satisfactorily.

1 -

An additional advantage of a flSaion counter la that it does not suffer the rapid lifetime degradation common to B 10 and BF, counters.

in all potential app!! cations the inherent low sensitivity (0.14 ces/nv in 0 R/ht) must be weighed against the advantage of satisfactory performance (with reduced neutron sensitivity)in a high gamma environment.

In all cases of operation in a high gamma flux.

perdermance is greatly dependent on associated electronics. High count rate electronics are required for optimum performance.

The unit is constructed of aluminum alloy for minimum neutron absorption and residual activity.

All seals are ceramic to-metal. Insulators are high purity alumina.

fl H f\\

U1 DD

1) i1i g'U6 E

p4

.oroy - I q Tmcat coNut c non p%nau i

Specifications p

t y

i M ECH ANIC AL.

-. %)

, t umum eumer..

.................... 2 8 2 cm

~

' E ~ ' AQ 8 unum emune........

........ ass em ca m a.

................... Tra un

_ y y

Outa sheit aN inner entode6................ Atmhm 4.%f I, ?

p' MATERIAL g

Connecor.....................

......... AWnum Ale'.a custn c hsu'xiort Otteca.

t Connxtar....

.. AWeJ certt4 a

Ns. tron sent>. ke ina*.sf.al.

.... I.)ranium enrivM 93% in 4235 i

Total @a 'JV c1 &235...................... 12fno 3

RI gas.........

76 cm Hg - kpVfarecen

.~

f P

P

.v

=

s.>

C AP ACITAN C E.......................

40 s t

j.

"c' -... y <;

p

  • g; a RESISTANCE @ 25' C.......

10'8 of.ms (mWmum)

L MAXIMUM MATINOS

]

V f3@e.......

800 Vor.:

y'INTEGHAt HIA!. LUHvt 5

TCmpSrIturl.

300* C

%,,,y %,,,,,

Bras tie.

c

.s for 10% cecrease m serfuy....

. 2 x ion nA merma0 b*

hx...

.se;.

r TYPICAL OPERATING CH ARACTERISTICS i

Thermal rerstm sensWty(Nete 1).

0.14 coo /nv 220%

V0)(

s i

Theal nm.t on fks ramo...

....... e 10' ru a"

Vd'#)Sf3@e.........

3% to 800 Vots

~2

?

I Ougut pulse drracters*ics (aenge) f f

I E

i Char @8 Output..

3 X 10 '8 ccdores t

CdWtkn 600...

........... d 200 ria csocorifs

+

f.e,p.s;., ;

3

'a t-non 1: the ews y is mea uw e ava tzywe court ram fr:n

_. u o

ura W.n sa:rg at < 1 CDs. S6rdMy e!xs la not a#.f.N for

-i patteason.

1- :

N lI

_~

~

N O

^

^ '

.D 3

(

[

~

(47T i

L,.s, i

. pg uwgg,y.,

f

.'t.6...

6... 114..v. '.,....

.c

. +

x..

=

lia... (

H.,

[.,

3:

.f,h't p

, y).; u

.y'.. p' f,-jpgmQ,
y'-}'w;:)'

.3

_ m..

,ww v.

w

_. _ _ _ _. _ _ _