February 7, 1997 P'D S MEMORANDUM FOR:

Singh S. Bajwa, Acting Director Project Directorate I-1 Division of Reactor Projects I/II, NRR FROM:

Gerald H. Weidenhamer Electrical, Materials and Mechanical Engineering Branch Division of Engineering Technology, RES

SUBJECT:

TEST DATA FOR NIAGARA MOHAWK POWER CORPORATION The attached letter, dated January 31, 1997, from Mr. M.J. McCormick, Jr., requests data from some of the NRC sponsored tests on pressure locking of motor-operated gate valves. The letter states that the data will be used by the licensee to support their evaluations and preparations for a predecisional enforcement conference with NRC Region I.

Since I am the RE5 project manager for the pressure locking valve tests, the request was addressed to me.

I am attaching the data, in the form of two disks, for your use in responding to the request. Please note that Mr. McCormick requests the data be sent directly to Kalsi Engineering. Inc.

745 Park Two Drive. Sugar Land. Texas, 77478.

A sketch of the instrumen*ation arrangement (Figure 3) installed on the valves for the tests and a listing of the instrumentation channels (Table 1) are also attached and are necessary for understanding the data.

In addition, the process for loading the data files is attached.

It is suggested that a disclaimer notice be included as part of the response to Kalsi Engineering and to the licensee. The following is offered as a possible candidate:

"The attached disks were prepared from work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibility of any third party's use, or the results of such use, of any information disclosed on the disks, or requests that its use by such third party would not infringe privately owned rights."

l If I can be of further assistance regarding this matter, please call me on 415-6015.

l Attachments: As stated h[ )o Otstnbution:

w k

with Data Diskt M d!#1ji t Signature Fde (LCS)

Public Docur..er:t Room Branch Reading Fue c-Document Control Desk R.H.VVessman T.G Scarbrough

~}fQQf]

D J.T.Wiggtns E M Kelly L.T.Doerflein DOCUMENT NAME: G:\\WEIDENHA\\NIAGARAM.OH To receive a copy of this document, indicate in the box; "C" = Copy without attachment / enclosure "E" - Copy with attachmentrenclosura "N" = No copy f

OFFICE EMMEB yk j lE-l SC\\EMMEB _ n lCl CWMER ( dj l

l l

l NAME P G WeidelfirIa' er J Vora,Q. > d6 M.M a yfield[MI m

D ATE ") /'l 02/ Cl 19 7 02/ O/

' /97 02/ O' 79 7 lbbk I b \\k

]

f. -

1 ATTACHMENT l

i i

, NIAGARA MOHAWK i G E N E R ATIO N ma m.: pommetaan smMLAKE ROAD. P.O. BOX 63. LYCOM!NG, NEW YORK 13093 l

BUSINESS GROUP January 31,1997 NMP2L 1685 U.S. Nuclear Regulatory Commission l

One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738 Attn: Dr. Gerald H. Weidenhamer, Mail Stop 10E10 RE:

Nine Mile Point Unit 2 l

Docket No. 50-410 NPF-69

Subject:

Requestfor Pressure Locking Test Information

Dear Dr. Weidenhamer:

As explained by members of my staff, Niagara Mohawk Power Corporation (NMPC) would like for the following pressure locking testing results be provided to our consultant, Kalsi Engineering, Inc., to support our evaluations and preparations for a predecisional enforcement conference with NRC Region I.

Pressure locking tests with motor-torque measurements Test Test Test Parameters Stroke Type (PsIg)

Walworth:

V3002 S

0 0

70 V30ll PL 100.

0 70 V3012 PL 1200 0

70 V3013 HD 1250 1250 0

70 V3014 S

0 0

0 70 V3017 PL 1200 0

0 70

)

V3 BHT 9 PL 1015 0

0 205 l

l A/D:

ADP01 S

0 0

0 70 j

ADP02 HD 1200 1200 0

70 ADP03 HD

\\1200 0

1200 70 l

996&'M?

4' Page 2 We believe that the requested data will assist us in determining the validity of our assumptions used in GL 89-10 calculations. It is noted that in order to utilize the data in a time frame i

4 l

consistent with our requirements, we would like to receive this information by February 7,1997.

If you have any questions concerning this request, contact Mr. G. J. Gresock at (315) 349-7010.

Very truly yours, gc g

M. J. McCormick Jr Vice President Nuclear Engineering

' MJM/GJG/ kap xc:

Document Control Desk Regional Administrator, Region I Mr. S. S. Bajwa, Acting Director, Project Directorate I-1, NRR Mr. B. S. Norris, Senior Resident Inspector Mr. D. S. Hood, Senior Project Manager, NRR Records Management

i ATTACHMENT I 73 7

TlTh]

Leaend j

< gg

~

B Low pressure pump

^ W!

.H\\/

.d O Pressure K

F]

8 High pressure pump

[/~

E Temperature r

F 8

Heater

_ _[g G Valve position f

g ljD Valve current and power x

'x 8 Valve voltage f

/

X

@ Torque spring deflection

]{'gg and force g'

X-l-

b

,_d "g

E Stem force and stem torque m

X X

8 Motor speed

@ Drain 8

Reservoir E

D.I. water E

Motortorque E

Stem position 8 Airinjection B

High point vent 0

curw,a.m mr Figure 3. Test setup and instrumentation for the pressure locking tests.

i

,r,

.,.._..-.,..m

,--.w.~.w.,

i-,.~

_-.,,-3,.y

-1 1

Table 1. Test instrumentation.-

l TCS channel-Description Calibration-Channel ^1-Bonnet fluid temperature Yes Channel 02 "

Upstream fluid temperature Yes Channel 03 Downstream fluid temperature Yes Channel 16 Motor current, II, RMS Yes 1

L Channel 19 Motor voltage, V1-2, RMS Yes Channe 21 Motor rotor temperature No. required t

1 Channel 32 Stem force (load cell)

Yes

.l L

channel 33 Torque spring force Yes L

^ Channel 34:

Bonnet pressure Yes Channel 35 Upstream pressure Yes L

Channel 36 b,wnstream pressure Yes Channel 40 Motor torque Yes Channel 50 Stem force (Smart Stem)

Yes L.

Channel 51 Stem torque (Smart Stem)

Yes j

Channel 66 Torque switch Not required Yes l

Channel 67 -

Motor power Channel 68 Motor power factor Yes l

. Channel 69 Torque spring position Yes Channel 72 Motor speed Yes

. Channel 74 Transformer voltage Not required channel 75 -

Stem position Not required Channel 77 Motor current, II, Peak Yes Channel 78 Motor current,12, Peak Yes Channel 79 Motor current, I3, Peak Yes o

a r

.. ~ ~.

ATTACHMENT i

l PROCESS FOR LOADING DATA FILES The data files contained on disks 1 and 2 are in DADiSP Labbook format.

They have also been compressed using the PKZIP software.

To load the data files into DADiSP, first run DADiSP and create new Labbooks having the same name as each data file.

Note that the 'D" at the end of the file name indicates DADiSP format and is not part of the Labbook name.

I Example:

For file name V3002D. ZIP, create Labbook V3002 i

i Next, exit CADiSP and enter the DOS subdirectory matching the newly created Labbook.

Example:

CDC:\\DSP\\V3002 l

Finally, " unzip" the data 'ile that matches the Labbook name.

PKZIP will question if you want to ove. write the INDEX.PI file - you must answer YES.

i Example:

PKUNZIP A:\\V30020. ZIP j

The data should now be loaded into the DADiSP Labbook and available for i

analysis.

i I

i 1

e i

5

-