Category:INSPECTION REPORT
MONTHYEARIR 05000313/19990121999-09-0101 September 1999 Insp Repts 50-313/99-12 & 50-368/99-12 on 990711-0821.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19990111999-08-12012 August 1999 Insp Repts 50-313/99-11 & 50-368/99-11 on 990719-23.No Violations Noted.Major Areas Inspected:Licensee Requalification Program IR 05000313/19990081999-07-21021 July 1999 Insp Repts 50-313/99-08 & 50-368/99-08 on 990530-0710.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19990051999-06-10010 June 1999 Insp Repts 50-313/99-05 & 50-368/99-05 on 990411-0529.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000313/19990061999-06-0808 June 1999 Insp Repts 50-313/99-06 & 50-368/99-06 on 990524-28. Violations Identified & Being Treated as Noncited Violation. Major Areas Inspected:Radiological Environ Monitoring Program IR 05000313/19980211999-05-24024 May 1999 Insp Repts 50-313/98-21 & 50-368/98-01 on 981116-990406.One Violation Occurred & Being Treated as non-cited Violation. Major Areas Inspected:Review of Licensee Implementation of post-fire Alternative Shutdown Requirements ML20206S4881999-05-14014 May 1999 Insp Repts 50-313/99-07 & 50-368/99-07 on 990426-30.No Violations Noted.Major Areas Inspected:Access Authorization, Alarm Stations,Communications,Protected Area Access Control of Personnel,Packages & Vehicles & Assessment Aids IR 05000313/19990041999-05-10010 May 1999 Insp Repts 50-313/99-04 & 50-368/99-04 on 990228-0410. Non-cited Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19990031999-04-0909 April 1999 Insp Repts 50-313/99-03 & 50-368/99-03 on 990202-17.No Violations Noted.Major Areas Inspected:Operations IR 05000313/19990011999-04-0202 April 1999 Insp Repts 50-313/99-01 & 50-368/99-01 on 990117-0227.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980101999-02-0909 February 1999 Insp Repts 50-313/98-10 & 50-368/98-10 on 981206-990116.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19990021999-01-25025 January 1999 Insp Repts 50-313/99-02 & 50-368/99-02 on 990111-15.No Violations Noted.Major Areas Inspected:Exposure Controls, Controls of Radioactive Matl & Contamination,Surveying & Monitoring & Program to Maintain Occupational Exposure IR 05000313/19980091998-12-21021 December 1998 Insp Repts 50-313/98-09 & 50-368/98-09 on 981025-1205.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980081998-11-19019 November 1998 Insp Repts 50-313/98-08 & 50-368/98-08 on 980913-1024. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980191998-11-11011 November 1998 Insp Repts 50-313/98-19 & 50-368/98-19 on 981019-22.No Violations Noted.Major Areas Inspected:Exposure Controls, Control of Radioactive Matls & Contamination,Surveying & Monitoring & QA Oversight of Radiation Protection Program IR 05000313/19980201998-10-27027 October 1998 Insp Repts 50-313/98-20 & 50-368/98-20 on 981019-22.No Violations Noted.Major Areas Inspected:Operational Status of Licensee Emergency Preparedness Program IR 05000313/19980071998-10-15015 October 1998 Corrected Pages to Insp Repts 50-313/98-07 & 50-368/98-07 on 980925.Typo Was Identified in Numbering of Insp Followup Sys Closed Items ML20153H2461998-09-25025 September 1998 Insp Repts 50-313/98-07 & 50-368/98-07 on 980802-0912.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000313/19980161998-09-15015 September 1998 Insp Repts 50-313/98-16 & 50-368/98-16 on 980831-0904.No Violations Noted.Major Areas Inspected:Testing & Maintenance,Protected Area Barrier & Detection Aids, Compensatory Measures & Security Sys Power Supply IR 05000313/19980111998-09-0303 September 1998 Insp Repts 50-313/98-11 & 50-368/98-11 Has Been Canceled.No Other Rept Will Be Issued IR 05000313/19980151998-09-0202 September 1998 Insp Repts 50-313/98-15 & 50-368/98-15 on 980818-21.No Violations Noted.Major Areas Inspected:Licensee Performance & Capabilities During full-scale,biennial Exercise of Emergency Plan & Implementing Procedures IR 05000313/19980061998-08-18018 August 1998 Insp Repts 50-313/98-06 & 50-368/98-06 on 980621-0801. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19980051998-07-16016 July 1998 Insp Repts 50-313/98-05 & 50-368/98-05 on 980510-0620.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19980041998-06-0404 June 1998 Insp Repts 50-313/98-04 & 50-368/98-04 on 980329-0509. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20216D2521998-05-11011 May 1998 Errata to Insp Repts 50-313/98-12 & 50-368/98-12 ML20247K0301998-05-0808 May 1998 Insp Repts 50-313/98-14 & 50-368/98-14 on 980427-0501. Violations Noted.Major Areas Inspected:Access Authorization, Alarm Stations,Communications,Access Control of Personnel & Packages & Vehicles ML20217A9351998-04-17017 April 1998 Insp Repts 50-313/98-03 & 50-368/98-03 on 980215-0328. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19980131998-04-14014 April 1998 Insp Repts 50-313/98-13 & 50-368/98-13 on 980330-0403. Violations Noted.Major Areas Inspected:Review of Radiation Protection Program Focussing on Unit 1 Refueling Outage Activities ML20217N3021998-04-0202 April 1998 Insp Repts 50-313/98-12 & 50-368/98-12 on 980302-11. Violations Noted.Major Areas Inspected:Maint & Engineering ML20216B8751998-03-10010 March 1998 Insp Repts 50-313/98-02 & 50-368/98-02 on 980104-0214. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20202E3401998-02-0606 February 1998 Insp Repts 50-313/97-21 & 50-368/97-21 on 971027-31 & 1110- 14.Violations Noted.Major Areas Inspected:Engineering & Plant Support.Nrc Identified Fire Barrier Deficiency & Licensee Took Promp Compensatory Actions as Required IR 05000313/19970081998-01-23023 January 1998 Insp Repts 50-313/97-08 & 50-368/97-08 on 971123-980103.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19970201997-12-17017 December 1997 Insp Repts 50-313/97-20 & 50-368/97-20 on 971117-20.No Violations Noted.Major Areas Inspected:Plant Support, Radiological Protection & Chemistry Controls & Status of Radiological Protection & Chemistry Facilities & Equipment IR 05000313/19970071997-12-12012 December 1997 Insp Repts 50-313/97-07 & 50-368/97-07 on 971011-1122.No Violations Noted.Major Areas Inspected:Operations, Maintenance & Plant Support IR 05000313/19970181997-12-0606 December 1997 Insp Repts 50-313/97-18 & 50-368/97-18 on 971020-1107. Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support IR 05000313/19970191997-11-28028 November 1997 Insp Repts 50-313/97-19 & 50-368/97-19 on 971103-06. Violations Noted.Major Areas Inspected:Exposure Controls, Radioactive Matl & Contamination,Surveying,Monitoring & Quality Assurance in Radiation Protection Activities IR 05000313/19970221997-11-28028 November 1997 Insp Repts 50-313/97-22 & 50-368/97-22 on 971117-22.No Violations Noted.Major Areas Inspected:Protected & Vital Area Barriers & Detention Aids,Security Sys Power Supply, Event Logs,Training & Qualifications IR 05000313/19970061997-11-0606 November 1997 Insp Repts 50-313/97-06 & 50-368/97-06 on 970831-1011.No Violations Noted.Major Areas Inspected:Operation,Maint & Plant Support IR 05000313/19970171997-09-17017 September 1997 Insp Repts 50-313/97-17 & 50-368/97-17 on 970825-28. Violations Noted.Major Areas Inspected:Routine,Announced Insp of Liquid & Gaseous Radioactive Effluent Waste Mgt Program Including Organization & Mgt Controls IR 05000313/19970051997-09-16016 September 1997 Insp Repts 50-313/97-05 & 50-368/97-05 on 970720-0830. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000313/19970141997-09-12012 September 1997 Insp Repts 50-313/97-14 & 50-368/97-14 on 970527-0807.No Violations Noted.Major Areas Inspected:Maint & Engineering IR 05000313/19970111997-08-15015 August 1997 Insp Repts 50-313/97-11 & 50-368/97-11 on 970728-0801.No Violations Noted.Major Areas Inspected:Licensee Requalification Program IR 05000313/19970161997-08-0101 August 1997 Insp Repts 50-313/97-16 & 50-368/97-16 on 970721-25.No Violations Noted.Major Areas Inspected:Records & Repts, Testing & Maint,Assessment Aids,Alarm Stations, Communications,Security Plans & Procedures ML20151J9231997-07-30030 July 1997 Insp Repts 50-313/97-04 & 50-368/97-04 on 970608-0719. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000313/19972011997-07-24024 July 1997 Insp Rept 50-313/97-201 on 970210-0314.Violations Noted. Major Areas Inspected:Design Inspection of EFW & Decay Heat/Low Pressure Injection System ML20148T0091997-07-0101 July 1997 Insp Repts 50-313/97-03 & 50-368/97-03 on 970427-0607. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20148P5921997-06-28028 June 1997 Insp Repts 50-313/97-13 & 50-368/97-13 on 970512-0605. Violations Noted.Major Areas Inspected:Maintenance & Engineering ML20148P5851997-06-28028 June 1997 Insp Repts 50-313/97-15 & 50-368/97-15 on 970602-06. Violations Noted.Major Areas Inspected:Plant Support Re Controlled Access Area IR 05000313/19960281997-05-21021 May 1997 Insp Repts 50-313/96-28 & 50-368/96-28 on 961125-1213.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering ML20141G7451997-05-19019 May 1997 Insp Repts 50-313/97-02 & 50-368/97-02 on 970316-0426. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint, & Plant Support 1999-09-01
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000313/19990121999-09-0101 September 1999 Insp Repts 50-313/99-12 & 50-368/99-12 on 990711-0821.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19990111999-08-12012 August 1999 Insp Repts 50-313/99-11 & 50-368/99-11 on 990719-23.No Violations Noted.Major Areas Inspected:Licensee Requalification Program IR 05000313/19990081999-07-21021 July 1999 Insp Repts 50-313/99-08 & 50-368/99-08 on 990530-0710.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19990051999-06-10010 June 1999 Insp Repts 50-313/99-05 & 50-368/99-05 on 990411-0529.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000313/19990061999-06-0808 June 1999 Insp Repts 50-313/99-06 & 50-368/99-06 on 990524-28. Violations Identified & Being Treated as Noncited Violation. Major Areas Inspected:Radiological Environ Monitoring Program IR 05000313/19980211999-05-24024 May 1999 Insp Repts 50-313/98-21 & 50-368/98-01 on 981116-990406.One Violation Occurred & Being Treated as non-cited Violation. Major Areas Inspected:Review of Licensee Implementation of post-fire Alternative Shutdown Requirements ML20206S4881999-05-14014 May 1999 Insp Repts 50-313/99-07 & 50-368/99-07 on 990426-30.No Violations Noted.Major Areas Inspected:Access Authorization, Alarm Stations,Communications,Protected Area Access Control of Personnel,Packages & Vehicles & Assessment Aids IR 05000313/19990041999-05-10010 May 1999 Insp Repts 50-313/99-04 & 50-368/99-04 on 990228-0410. Non-cited Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19990031999-04-0909 April 1999 Insp Repts 50-313/99-03 & 50-368/99-03 on 990202-17.No Violations Noted.Major Areas Inspected:Operations IR 05000313/19990011999-04-0202 April 1999 Insp Repts 50-313/99-01 & 50-368/99-01 on 990117-0227.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980101999-02-0909 February 1999 Insp Repts 50-313/98-10 & 50-368/98-10 on 981206-990116.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19990021999-01-25025 January 1999 Insp Repts 50-313/99-02 & 50-368/99-02 on 990111-15.No Violations Noted.Major Areas Inspected:Exposure Controls, Controls of Radioactive Matl & Contamination,Surveying & Monitoring & Program to Maintain Occupational Exposure IR 05000313/19980091998-12-21021 December 1998 Insp Repts 50-313/98-09 & 50-368/98-09 on 981025-1205.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980081998-11-19019 November 1998 Insp Repts 50-313/98-08 & 50-368/98-08 on 980913-1024. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980191998-11-11011 November 1998 Insp Repts 50-313/98-19 & 50-368/98-19 on 981019-22.No Violations Noted.Major Areas Inspected:Exposure Controls, Control of Radioactive Matls & Contamination,Surveying & Monitoring & QA Oversight of Radiation Protection Program IR 05000313/19980201998-10-27027 October 1998 Insp Repts 50-313/98-20 & 50-368/98-20 on 981019-22.No Violations Noted.Major Areas Inspected:Operational Status of Licensee Emergency Preparedness Program IR 05000313/19980071998-10-15015 October 1998 Corrected Pages to Insp Repts 50-313/98-07 & 50-368/98-07 on 980925.Typo Was Identified in Numbering of Insp Followup Sys Closed Items ML20153H2461998-09-25025 September 1998 Insp Repts 50-313/98-07 & 50-368/98-07 on 980802-0912.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000313/19980161998-09-15015 September 1998 Insp Repts 50-313/98-16 & 50-368/98-16 on 980831-0904.No Violations Noted.Major Areas Inspected:Testing & Maintenance,Protected Area Barrier & Detection Aids, Compensatory Measures & Security Sys Power Supply IR 05000313/19980111998-09-0303 September 1998 Insp Repts 50-313/98-11 & 50-368/98-11 Has Been Canceled.No Other Rept Will Be Issued IR 05000313/19980151998-09-0202 September 1998 Insp Repts 50-313/98-15 & 50-368/98-15 on 980818-21.No Violations Noted.Major Areas Inspected:Licensee Performance & Capabilities During full-scale,biennial Exercise of Emergency Plan & Implementing Procedures IR 05000313/19980061998-08-18018 August 1998 Insp Repts 50-313/98-06 & 50-368/98-06 on 980621-0801. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19980051998-07-16016 July 1998 Insp Repts 50-313/98-05 & 50-368/98-05 on 980510-0620.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19980041998-06-0404 June 1998 Insp Repts 50-313/98-04 & 50-368/98-04 on 980329-0509. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20216D2521998-05-11011 May 1998 Errata to Insp Repts 50-313/98-12 & 50-368/98-12 ML20247K0301998-05-0808 May 1998 Insp Repts 50-313/98-14 & 50-368/98-14 on 980427-0501. Violations Noted.Major Areas Inspected:Access Authorization, Alarm Stations,Communications,Access Control of Personnel & Packages & Vehicles ML20217A9351998-04-17017 April 1998 Insp Repts 50-313/98-03 & 50-368/98-03 on 980215-0328. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19980131998-04-14014 April 1998 Insp Repts 50-313/98-13 & 50-368/98-13 on 980330-0403. Violations Noted.Major Areas Inspected:Review of Radiation Protection Program Focussing on Unit 1 Refueling Outage Activities ML20217N3021998-04-0202 April 1998 Insp Repts 50-313/98-12 & 50-368/98-12 on 980302-11. Violations Noted.Major Areas Inspected:Maint & Engineering ML20216B8751998-03-10010 March 1998 Insp Repts 50-313/98-02 & 50-368/98-02 on 980104-0214. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20202E3401998-02-0606 February 1998 Insp Repts 50-313/97-21 & 50-368/97-21 on 971027-31 & 1110- 14.Violations Noted.Major Areas Inspected:Engineering & Plant Support.Nrc Identified Fire Barrier Deficiency & Licensee Took Promp Compensatory Actions as Required IR 05000313/19970081998-01-23023 January 1998 Insp Repts 50-313/97-08 & 50-368/97-08 on 971123-980103.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19970201997-12-17017 December 1997 Insp Repts 50-313/97-20 & 50-368/97-20 on 971117-20.No Violations Noted.Major Areas Inspected:Plant Support, Radiological Protection & Chemistry Controls & Status of Radiological Protection & Chemistry Facilities & Equipment IR 05000313/19970071997-12-12012 December 1997 Insp Repts 50-313/97-07 & 50-368/97-07 on 971011-1122.No Violations Noted.Major Areas Inspected:Operations, Maintenance & Plant Support IR 05000313/19970181997-12-0606 December 1997 Insp Repts 50-313/97-18 & 50-368/97-18 on 971020-1107. Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support IR 05000313/19970191997-11-28028 November 1997 Insp Repts 50-313/97-19 & 50-368/97-19 on 971103-06. Violations Noted.Major Areas Inspected:Exposure Controls, Radioactive Matl & Contamination,Surveying,Monitoring & Quality Assurance in Radiation Protection Activities IR 05000313/19970221997-11-28028 November 1997 Insp Repts 50-313/97-22 & 50-368/97-22 on 971117-22.No Violations Noted.Major Areas Inspected:Protected & Vital Area Barriers & Detention Aids,Security Sys Power Supply, Event Logs,Training & Qualifications IR 05000313/19970061997-11-0606 November 1997 Insp Repts 50-313/97-06 & 50-368/97-06 on 970831-1011.No Violations Noted.Major Areas Inspected:Operation,Maint & Plant Support IR 05000313/19970171997-09-17017 September 1997 Insp Repts 50-313/97-17 & 50-368/97-17 on 970825-28. Violations Noted.Major Areas Inspected:Routine,Announced Insp of Liquid & Gaseous Radioactive Effluent Waste Mgt Program Including Organization & Mgt Controls IR 05000313/19970051997-09-16016 September 1997 Insp Repts 50-313/97-05 & 50-368/97-05 on 970720-0830. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000313/19970141997-09-12012 September 1997 Insp Repts 50-313/97-14 & 50-368/97-14 on 970527-0807.No Violations Noted.Major Areas Inspected:Maint & Engineering IR 05000313/19970111997-08-15015 August 1997 Insp Repts 50-313/97-11 & 50-368/97-11 on 970728-0801.No Violations Noted.Major Areas Inspected:Licensee Requalification Program IR 05000313/19970161997-08-0101 August 1997 Insp Repts 50-313/97-16 & 50-368/97-16 on 970721-25.No Violations Noted.Major Areas Inspected:Records & Repts, Testing & Maint,Assessment Aids,Alarm Stations, Communications,Security Plans & Procedures ML20151J9231997-07-30030 July 1997 Insp Repts 50-313/97-04 & 50-368/97-04 on 970608-0719. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000313/19972011997-07-24024 July 1997 Insp Rept 50-313/97-201 on 970210-0314.Violations Noted. Major Areas Inspected:Design Inspection of EFW & Decay Heat/Low Pressure Injection System ML20148T0091997-07-0101 July 1997 Insp Repts 50-313/97-03 & 50-368/97-03 on 970427-0607. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20148P5921997-06-28028 June 1997 Insp Repts 50-313/97-13 & 50-368/97-13 on 970512-0605. Violations Noted.Major Areas Inspected:Maintenance & Engineering ML20148P5851997-06-28028 June 1997 Insp Repts 50-313/97-15 & 50-368/97-15 on 970602-06. Violations Noted.Major Areas Inspected:Plant Support Re Controlled Access Area IR 05000313/19960281997-05-21021 May 1997 Insp Repts 50-313/96-28 & 50-368/96-28 on 961125-1213.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering ML20141G7451997-05-19019 May 1997 Insp Repts 50-313/97-02 & 50-368/97-02 on 970316-0426. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint, & Plant Support 1999-09-01
[Table view] Category:INSPECTION REPORT
MONTHYEARIR 05000313/19990121999-09-0101 September 1999 Insp Repts 50-313/99-12 & 50-368/99-12 on 990711-0821.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19990111999-08-12012 August 1999 Insp Repts 50-313/99-11 & 50-368/99-11 on 990719-23.No Violations Noted.Major Areas Inspected:Licensee Requalification Program IR 05000313/19990081999-07-21021 July 1999 Insp Repts 50-313/99-08 & 50-368/99-08 on 990530-0710.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19990051999-06-10010 June 1999 Insp Repts 50-313/99-05 & 50-368/99-05 on 990411-0529.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000313/19990061999-06-0808 June 1999 Insp Repts 50-313/99-06 & 50-368/99-06 on 990524-28. Violations Identified & Being Treated as Noncited Violation. Major Areas Inspected:Radiological Environ Monitoring Program IR 05000313/19980211999-05-24024 May 1999 Insp Repts 50-313/98-21 & 50-368/98-01 on 981116-990406.One Violation Occurred & Being Treated as non-cited Violation. Major Areas Inspected:Review of Licensee Implementation of post-fire Alternative Shutdown Requirements ML20206S4881999-05-14014 May 1999 Insp Repts 50-313/99-07 & 50-368/99-07 on 990426-30.No Violations Noted.Major Areas Inspected:Access Authorization, Alarm Stations,Communications,Protected Area Access Control of Personnel,Packages & Vehicles & Assessment Aids IR 05000313/19990041999-05-10010 May 1999 Insp Repts 50-313/99-04 & 50-368/99-04 on 990228-0410. Non-cited Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19990031999-04-0909 April 1999 Insp Repts 50-313/99-03 & 50-368/99-03 on 990202-17.No Violations Noted.Major Areas Inspected:Operations IR 05000313/19990011999-04-0202 April 1999 Insp Repts 50-313/99-01 & 50-368/99-01 on 990117-0227.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980101999-02-0909 February 1999 Insp Repts 50-313/98-10 & 50-368/98-10 on 981206-990116.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19990021999-01-25025 January 1999 Insp Repts 50-313/99-02 & 50-368/99-02 on 990111-15.No Violations Noted.Major Areas Inspected:Exposure Controls, Controls of Radioactive Matl & Contamination,Surveying & Monitoring & Program to Maintain Occupational Exposure IR 05000313/19980091998-12-21021 December 1998 Insp Repts 50-313/98-09 & 50-368/98-09 on 981025-1205.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980081998-11-19019 November 1998 Insp Repts 50-313/98-08 & 50-368/98-08 on 980913-1024. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980191998-11-11011 November 1998 Insp Repts 50-313/98-19 & 50-368/98-19 on 981019-22.No Violations Noted.Major Areas Inspected:Exposure Controls, Control of Radioactive Matls & Contamination,Surveying & Monitoring & QA Oversight of Radiation Protection Program IR 05000313/19980201998-10-27027 October 1998 Insp Repts 50-313/98-20 & 50-368/98-20 on 981019-22.No Violations Noted.Major Areas Inspected:Operational Status of Licensee Emergency Preparedness Program IR 05000313/19980071998-10-15015 October 1998 Corrected Pages to Insp Repts 50-313/98-07 & 50-368/98-07 on 980925.Typo Was Identified in Numbering of Insp Followup Sys Closed Items ML20153H2461998-09-25025 September 1998 Insp Repts 50-313/98-07 & 50-368/98-07 on 980802-0912.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000313/19980161998-09-15015 September 1998 Insp Repts 50-313/98-16 & 50-368/98-16 on 980831-0904.No Violations Noted.Major Areas Inspected:Testing & Maintenance,Protected Area Barrier & Detection Aids, Compensatory Measures & Security Sys Power Supply IR 05000313/19980111998-09-0303 September 1998 Insp Repts 50-313/98-11 & 50-368/98-11 Has Been Canceled.No Other Rept Will Be Issued IR 05000313/19980151998-09-0202 September 1998 Insp Repts 50-313/98-15 & 50-368/98-15 on 980818-21.No Violations Noted.Major Areas Inspected:Licensee Performance & Capabilities During full-scale,biennial Exercise of Emergency Plan & Implementing Procedures IR 05000313/19980061998-08-18018 August 1998 Insp Repts 50-313/98-06 & 50-368/98-06 on 980621-0801. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19980051998-07-16016 July 1998 Insp Repts 50-313/98-05 & 50-368/98-05 on 980510-0620.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19980041998-06-0404 June 1998 Insp Repts 50-313/98-04 & 50-368/98-04 on 980329-0509. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20216D2521998-05-11011 May 1998 Errata to Insp Repts 50-313/98-12 & 50-368/98-12 ML20247K0301998-05-0808 May 1998 Insp Repts 50-313/98-14 & 50-368/98-14 on 980427-0501. Violations Noted.Major Areas Inspected:Access Authorization, Alarm Stations,Communications,Access Control of Personnel & Packages & Vehicles ML20217A9351998-04-17017 April 1998 Insp Repts 50-313/98-03 & 50-368/98-03 on 980215-0328. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19980131998-04-14014 April 1998 Insp Repts 50-313/98-13 & 50-368/98-13 on 980330-0403. Violations Noted.Major Areas Inspected:Review of Radiation Protection Program Focussing on Unit 1 Refueling Outage Activities ML20217N3021998-04-0202 April 1998 Insp Repts 50-313/98-12 & 50-368/98-12 on 980302-11. Violations Noted.Major Areas Inspected:Maint & Engineering ML20216B8751998-03-10010 March 1998 Insp Repts 50-313/98-02 & 50-368/98-02 on 980104-0214. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20202E3401998-02-0606 February 1998 Insp Repts 50-313/97-21 & 50-368/97-21 on 971027-31 & 1110- 14.Violations Noted.Major Areas Inspected:Engineering & Plant Support.Nrc Identified Fire Barrier Deficiency & Licensee Took Promp Compensatory Actions as Required IR 05000313/19970081998-01-23023 January 1998 Insp Repts 50-313/97-08 & 50-368/97-08 on 971123-980103.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19970201997-12-17017 December 1997 Insp Repts 50-313/97-20 & 50-368/97-20 on 971117-20.No Violations Noted.Major Areas Inspected:Plant Support, Radiological Protection & Chemistry Controls & Status of Radiological Protection & Chemistry Facilities & Equipment IR 05000313/19970071997-12-12012 December 1997 Insp Repts 50-313/97-07 & 50-368/97-07 on 971011-1122.No Violations Noted.Major Areas Inspected:Operations, Maintenance & Plant Support IR 05000313/19970181997-12-0606 December 1997 Insp Repts 50-313/97-18 & 50-368/97-18 on 971020-1107. Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support IR 05000313/19970191997-11-28028 November 1997 Insp Repts 50-313/97-19 & 50-368/97-19 on 971103-06. Violations Noted.Major Areas Inspected:Exposure Controls, Radioactive Matl & Contamination,Surveying,Monitoring & Quality Assurance in Radiation Protection Activities IR 05000313/19970221997-11-28028 November 1997 Insp Repts 50-313/97-22 & 50-368/97-22 on 971117-22.No Violations Noted.Major Areas Inspected:Protected & Vital Area Barriers & Detention Aids,Security Sys Power Supply, Event Logs,Training & Qualifications IR 05000313/19970061997-11-0606 November 1997 Insp Repts 50-313/97-06 & 50-368/97-06 on 970831-1011.No Violations Noted.Major Areas Inspected:Operation,Maint & Plant Support IR 05000313/19970171997-09-17017 September 1997 Insp Repts 50-313/97-17 & 50-368/97-17 on 970825-28. Violations Noted.Major Areas Inspected:Routine,Announced Insp of Liquid & Gaseous Radioactive Effluent Waste Mgt Program Including Organization & Mgt Controls IR 05000313/19970051997-09-16016 September 1997 Insp Repts 50-313/97-05 & 50-368/97-05 on 970720-0830. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000313/19970141997-09-12012 September 1997 Insp Repts 50-313/97-14 & 50-368/97-14 on 970527-0807.No Violations Noted.Major Areas Inspected:Maint & Engineering IR 05000313/19970111997-08-15015 August 1997 Insp Repts 50-313/97-11 & 50-368/97-11 on 970728-0801.No Violations Noted.Major Areas Inspected:Licensee Requalification Program IR 05000313/19970161997-08-0101 August 1997 Insp Repts 50-313/97-16 & 50-368/97-16 on 970721-25.No Violations Noted.Major Areas Inspected:Records & Repts, Testing & Maint,Assessment Aids,Alarm Stations, Communications,Security Plans & Procedures ML20151J9231997-07-30030 July 1997 Insp Repts 50-313/97-04 & 50-368/97-04 on 970608-0719. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000313/19972011997-07-24024 July 1997 Insp Rept 50-313/97-201 on 970210-0314.Violations Noted. Major Areas Inspected:Design Inspection of EFW & Decay Heat/Low Pressure Injection System ML20148T0091997-07-0101 July 1997 Insp Repts 50-313/97-03 & 50-368/97-03 on 970427-0607. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20148P5921997-06-28028 June 1997 Insp Repts 50-313/97-13 & 50-368/97-13 on 970512-0605. Violations Noted.Major Areas Inspected:Maintenance & Engineering ML20148P5851997-06-28028 June 1997 Insp Repts 50-313/97-15 & 50-368/97-15 on 970602-06. Violations Noted.Major Areas Inspected:Plant Support Re Controlled Access Area IR 05000313/19960281997-05-21021 May 1997 Insp Repts 50-313/96-28 & 50-368/96-28 on 961125-1213.No Violations Noted.Major Areas Inspected:Operations,Maint & Engineering ML20141G7451997-05-19019 May 1997 Insp Repts 50-313/97-02 & 50-368/97-02 on 970316-0426. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint, & Plant Support 1999-09-01
[Table view] Category:UTILITY
MONTHYEARIR 05000313/19900301990-11-0707 November 1990 Insp Repts 50-313/90-30 & 50-368/90-30 on 900905-1016. Violations Noted.Major Areas Inspected:Onsite Event Followup,Operational Safety Verification,Mod Installation, Surveillance,Maint & Review of Previous Insp Findings ML20058G8541990-11-0505 November 1990 Insp Repts 50-313/90-32 & 50-368/90-32 on 900924-28.Major Areas Inspected:Select Portions of Occupational Radiation Protection,Transportation & Solid Radwaste Programs IR 05000313/19900311990-10-31031 October 1990 Insp Repts 50-313/90-31 & 50-368/90-31 on 901001-04.No Violations or Deviations Noted.Major Area Inspected:Training & Qualification Effectiveness IR 05000313/19900371990-10-30030 October 1990 Insp Repts 50-313/90-37 & 50-368/90-37 on 901015-19.No Violations or Deviations Noted.Major Areas Inspected: Verification of Isolation Component Exemptions IR 05000313/19900401990-10-29029 October 1990 Insp Repts 50-313/90-40 & 50-368/90-40 on 901015-19.No Violations or Deviations Noted.Areas Inspected:Inservice Insp Work Activities & Insp of Action on Previously Identified Insp Finding ML20058A5251990-10-15015 October 1990 Insp Repts 50-313/90-38 & 50-368/90-38 on 901001-05.No Violations Noted.Major Areas Inspected:Followup of Unresolved Issue Identified by Operational Safety Team Insp Re Verification That Control Ventilation Sys Meets Design IR 05000313/19900281990-09-12012 September 1990 Insp Rept 50-313/90-28 & 50-368/90-28 on 900827-31.No Violations or Deviations Noted.Major Areas inspected:post- Fire Safe Shutdown Capability Reverification & Assessment of Fire Protection/Prevention Programs IR 05000313/19900271990-08-30030 August 1990 Insp Repts 50-313/90-27 & 50-368/90-27 on 900813-17.No Violations Noted.Major Areas Inspected:Review of Records Program,Document Control Program & Design Changes & Mods Program IR 05000313/19900231990-08-23023 August 1990 Insp Repts 50-313/90-23 & 50-368/90-23 on 900716-20.No Violations or Deviations Noted.Major Areas Inspected:Liquid & Gaseous Waste Mgt & Water Chemistry Programs IR 05000313/19900261990-08-13013 August 1990 Insp Repts 50-313/90-26 & 50-368/90-26 on 900730-0803.No Violations or Deviations Noted.Major Areas Inspected: Procurement,Receipt,Storage & Handling of Equipment & Matls IR 05000313/19900191990-08-0707 August 1990 Insp Repts 50-313/90-19 & 50-368/90-19 on 900601-0715. Violations Noted.Major Areas Inspected:Onsite Followup of Events,Operational Safety Verification,Surveillance,Maint & Design Changes IR 05000313/19900221990-07-19019 July 1990 Cancelled Insp Repts 50-313/90-22 & 50-368/90-22 IR 05000313/19900181990-06-28028 June 1990 Insp Repts 50-313/90-18 & 50-368/90-18 on 900521-25.No Violations or Deviations Noted.Major Areas Inspected: Operational Status of Emergency Preparedness Program, Including Changes to Emergency Plan & EPIP IR 05000313/19900101990-06-21021 June 1990 Insp Repts 50-313/90-10 & 50-368/90-10 on 900514-0601.No Violations or Deviations Noted.Major Areas Inspected: Licensee Engineering & Technical Support Capabilities Re Svc Water Sys IR 05000313/19890331989-09-29029 September 1989 Partially Withheld Insp Repts 50-313/89-33 & 50-368/89-33 on 890828-0901 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Physical Security Program,Including Protected Area Physical Barriers & Assessment Aids & Testing & Maint IR 05000313/19890311989-09-0808 September 1989 Canceled Insps 50-313/89-31 & 50-368/89-31 IR 05000313/19890301989-09-0606 September 1989 Insp Repts 50-313/89-30 & 50-368/89-30 on 890701-0815. Violation Noted.Major Areas Inspected:Plant Status,Followup of Events,Followup on Previously Identified Items, Operational Safety Verification,Surveillance & Maint IR 05000313/19890291989-07-28028 July 1989 Insp Repts 50-313/89-29 & 50-368/89-29 on 890626-29.No Violations or Deviations Noted.Major Areas Inspected: Operational Status of Emergency Preparedness Program, Including Changes to Emergency Plan & Facilities IR 05000313/19890281989-07-21021 July 1989 Insp Repts 50-313/89-28 & 50-368/89-28 on 890601-30. Violations Noted.Major Areas Inspected:Plant Status,Followup of Events,Operational Safety Verification,Followup on Previously Identified Items,Maint & Surveillance IR 05000313/19890271989-07-0707 July 1989 Partially Withheld Safeguards Insp Repts 50-313/89-27 & 50-368/89-27 on 890605-09 (Ref 10CFR73.21).No Violations or Deviations Noted.Major Areas Inspected:Physical Security Program Including Mgt Support & Security Program Plan ML20246C8741989-07-0606 July 1989 Insp Repts 50-313/89-23 & 50-368/89-23 on 890605-14.No Violations Noted.Major Areas Inspected:Licensee Actions to Prevent & Respond to Loss of Dhr,Per Generic Ltr 88-17 IR 05000313/19890261989-06-21021 June 1989 Insp Repts 50-313/89-26 & 50-368/89-26 on 890605-09. Deviation Noted.Major Areas Inspected:Tech Spec Required Calibr Program & Preventive Maint Program Re Calibr of Plant Instrumentation for Components Not Addressed in Tech Specs ML20245D7581989-06-15015 June 1989 Insp Repts 50-313/89-18 & 50-368/89-18 on 890416-0531. Violation Noted.Major Areas Inspected:Plant Status,Followup on Previously Identified Items,Followup of Events, Operational Safety Verification & Testing of Mods ML20245A1371989-06-12012 June 1989 Insp Repts 50-313/89-24 & 50-368/89-24 on 890515-19.No Violations Noted.Major Areas Inspected:Radiation Protection Program as Set Forth in Core Insp Program ML20244C2021989-06-0707 June 1989 Partially Withheld Insp Repts 50-313/89-20 & 50-368/89-20 on 890501-05 (Ref 10CFR73.21).Violations Noted Re Inadequate Assessment Aids & Compensatory Measures.Major Areas Inspected:Physical Security Program,Including Mgt Support IR 05000313/19890211989-06-0202 June 1989 Insp Repts 50-313/89-21 & 50-368/89-21 on 890508-12.No Violations or Deviations Noted.Major Areas Inspected: Chemistry/Radiochemistry Program & Water Chemistry & Radiochemistry Confirmatory Measurements IR 05000313/19890101989-05-15015 May 1989 Insp Repts 50-313/89-10 & 50-368/89-10 on 890301-0415. Violations Noted.Major Areas Inspected:Plant Status,Followup of Events,Followup of IE Bulletins & ATWS Rule 10CFR50.62, Operational Safety Verification & Monthly Maint Observation IR 05000313/19890171989-05-10010 May 1989 Insp Repts 50-313/89-17 & 50-368/89-17 on 890417-21.No Violations or Deviations Noted.Major Areas Inspected: Licensee Implementation of Integrated Corrective Action & Followup Actions Re Unit 2 Extraction Steam Line Break IR 05000313/19890191989-05-10010 May 1989 Informs That NRC Insp Repts 50-313/89-19 & 50-368/89-19 Cancelled & No Insp Rept Will Be Issued for Rept Numbers IR 05000313/19890251989-05-10010 May 1989 Cancels Insp Repts 50-313/89-25 & 50-368/89-25.No Insp Rept Will Be Issued for Listed Rept Numbers IR 05000313/19890141989-05-0202 May 1989 Insp Repts 50-313/89-14 & 50-368/89-14 on 890403-07. Violations Noted.Major Areas Inspected:Licensee Liquid & Gaseous Radwaste Mgt Programs IR 05000313/19890131989-04-29029 April 1989 Advises That Insps 50-313/89-13 & 50-368/89-13 Canceled IR 05000313/19890161989-04-17017 April 1989 Insp Repts 50-313/89-16 & 50-368/89-16 on 890327-31. Violations Noted.Major Areas Inspected:Previously Identified Insp Findings & self-assessment Capabilities IR 05000313/19890121989-04-13013 April 1989 Insp Repts 50-313/89-12 & 50-368/89-12 on 890314-16.No Violations or Deviations Noted.Weaknesses Noted Re Delay in Notification of State.Major Areas Inspected:Annual Exercise of Emergency Plan & Procedures IR 05000313/19890151989-04-0303 April 1989 Insp Repts 50-313/89-15 & 50-368/89-15 on 890320-24.No Violations or Deviations Noted.Major Areas Inspected:Mod Testing Program & Followup to Previous Insp Findings IR 05000313/19890041989-03-31031 March 1989 Insp Repts 50-313/89-04 & 50-368/89-04 on 890206-17 & 20-24. Violations Noted.Major Areas inspected:long-term Followup Actions Re Equipment Malfunctions Which Occurred Following Turbine/Reactor Trip on 890120 IR 05000313/19890081989-03-30030 March 1989 Insp Repts 50-313/89-08 & 50-368/89-08 on 890227-0303.No Violations or Deviations Noted.Major Areas Inspected: Inservice Testing Program for Pumps & Valves & Actions Taken Re Previously Identified Insp Findings IR 05000313/19890091989-03-30030 March 1989 Insp Repts 50-313/89-09 & 50-368/89-09 on 890307-10.No Violations or Deviations Noted.Major Areas Inspected:Action on Previous Insp Findings,Dhr Sys Pipe Supports,Hanger Damage & Emergency Diesel Geneator Exhaust Manifold Fires IR 05000313/19890111989-03-29029 March 1989 Partially Withheld Insp Repts 50-313/89-11 & 50-368/89-11 on 890227-0303 (Ref 10CFR73.21).No Violations or Deviations Noted.Major Areas Inspected:Physical Security Program, Including Mgt Support,Security Program Plan & Audits IR 05000313/19890071989-03-27027 March 1989 Insp Repts 50-313/89-07 & 50-368/89-07 on 890313-17.No Violations Noted.Major Areas Inspected:Licensee Commitments Re Actions to Prevent Low Temp Overpressure Transient Conditions & Implementation of Instrument Calibration IR 05000313/19890051989-03-24024 March 1989 Insp Repts 50-313/89-05 & 50-368/89-05 on 890201-28. Violation Noted Re Rigging from Safety Piping.Major Areas Inspected:Maint,Followup of Events,Operational Safety Verification,Surveillance & Allegation Followup IR 05000313/19890061989-03-0909 March 1989 Insp Repts 50-313/89-06 & 50-368/89-06 on 890221-24.No Violations Noted.Unresolved Items Re Radiographic Exam Procedures for Penetrameters Noted.Major Areas Inspected: Mods to Unit 1 Hpis & Repair of Unit 2 Refueling Water Tank IR 05000313/19890021989-02-27027 February 1989 Insp Repts 50-313/89-02 & 50-368/89-02 on 890101-31. Violations Noted.Major Areas Inspected:Plant Status,Followup on Previously Identified Items,Lers & Events & Operational Safety & Monthly Maint/Surveillance Observations IR 05000313/19890031989-02-15015 February 1989 Insp Repts 50-313/89-03 & 50-368/89-03 on 890124-25.Major Areas Inspected:Circumstances Following 890120 Reactor Trip Leading to Reactor Coolant Backleakage Through HPSI Check Valve Which Failed to Seat IR 05000313/19880461988-12-0202 December 1988 Informs That Insps 50-313/88-46 & 50-368/88-46 Cancelled & No Insp Repts Will Be Issued for Rept Numbers IR 05000313/19880371988-11-22022 November 1988 Insp Repts 50-313/88-37 & 50-368/88-37 on 881017-1104.No Violations or Deviations Noted.Major Areas Inspected: Licensee Capability for self-assessment & Compliance W/ Respective OL Tech Spec Requirements ML20195G9941988-11-17017 November 1988 Insp Repts 50-313/88-35 & 50-368/88-35 on 881030-1104. Violation Noted.Major Areas Inspected:Unit 1 Containment Integrated Leak Rate Test IR 05000313/19880411988-11-16016 November 1988 Insp Repts 50-313/88-41 & 50-368/88-41 on 881103-04. Violations Noted.Major Areas Inspected:Events Surrounding Apparent Overexposure of One Worker Performing Maint Work During Refueling Outage IR 05000313/19880321988-11-15015 November 1988 Insp Repts 50-313/88-32 & 50-368/88-32 on 880916-1023. Violations Noted.Major Areas Inspected:Maint,Surveillance, Operational Safety Verification,Followup on LERs & Events IR 05000313/19880331988-10-27027 October 1988 Insp Repts 50-313/88-33 & 50-368/88-33 on 881002-07.No Violations or Deviations Noted.Major Areas Inspected: Licensee Responses O 10CFR50.62 Rule on Atws.Licensee Commits to Actions to Prevent low-temp Overpressure 1990-09-12
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000313/19990121999-09-0101 September 1999 Insp Repts 50-313/99-12 & 50-368/99-12 on 990711-0821.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19990111999-08-12012 August 1999 Insp Repts 50-313/99-11 & 50-368/99-11 on 990719-23.No Violations Noted.Major Areas Inspected:Licensee Requalification Program IR 05000313/19990081999-07-21021 July 1999 Insp Repts 50-313/99-08 & 50-368/99-08 on 990530-0710.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support ML20196D4851999-06-21021 June 1999 Partially Deleted Notice of Violation from Insp on 990204. Violation Noted.Ed Mccormic,Individual Licensed Operator, Violated 10CFR50.53(j) by Use of Illegal Drug (Marijuana) as Evidence by Confirmed Positive Test for Urine on 981222 IR 05000313/19990051999-06-10010 June 1999 Insp Repts 50-313/99-05 & 50-368/99-05 on 990411-0529.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000313/19990061999-06-0808 June 1999 Insp Repts 50-313/99-06 & 50-368/99-06 on 990524-28. Violations Identified & Being Treated as Noncited Violation. Major Areas Inspected:Radiological Environ Monitoring Program ML20207G8511999-06-0707 June 1999 Notice of Violation from Investigation Rept A4-1998-042 on 990127.Violation Noted:After 980528,ES Feemster,Initiated Reactor Simulator Training Attendance Record Indicating Attendance at 980528 Training Session Not Attended IR 05000313/19980211999-05-24024 May 1999 Insp Repts 50-313/98-21 & 50-368/98-01 on 981116-990406.One Violation Occurred & Being Treated as non-cited Violation. Major Areas Inspected:Review of Licensee Implementation of post-fire Alternative Shutdown Requirements ML20206S4881999-05-14014 May 1999 Insp Repts 50-313/99-07 & 50-368/99-07 on 990426-30.No Violations Noted.Major Areas Inspected:Access Authorization, Alarm Stations,Communications,Protected Area Access Control of Personnel,Packages & Vehicles & Assessment Aids IR 05000313/19990041999-05-10010 May 1999 Insp Repts 50-313/99-04 & 50-368/99-04 on 990228-0410. Non-cited Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19990031999-04-0909 April 1999 Insp Repts 50-313/99-03 & 50-368/99-03 on 990202-17.No Violations Noted.Major Areas Inspected:Operations IR 05000313/19990011999-04-0202 April 1999 Insp Repts 50-313/99-01 & 50-368/99-01 on 990117-0227.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980101999-02-0909 February 1999 Insp Repts 50-313/98-10 & 50-368/98-10 on 981206-990116.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000313/19990021999-01-25025 January 1999 Insp Repts 50-313/99-02 & 50-368/99-02 on 990111-15.No Violations Noted.Major Areas Inspected:Exposure Controls, Controls of Radioactive Matl & Contamination,Surveying & Monitoring & Program to Maintain Occupational Exposure IR 05000313/19983031999-01-0707 January 1999 NRC Operator Licensing Exam Rept 50-313/98-303 & 50-368/98-303 on 981218.Exam Results:On Reactor Operator License Applicant Passed Written Exam PNO-IV-98-066, on 981225,large Influx of Fish (Shad) Affected Unit 1 Intake Structure,Resulting in Degraded Available Circulating Water Pump Suction Pressure.Shade Runs Have Historically Occurred as Result of Cyclic Changes1998-12-29029 December 1998 PNO-IV-98-066:on 981225,large Influx of Fish (Shad) Affected Unit 1 Intake Structure,Resulting in Degraded Available Circulating Water Pump Suction Pressure.Shade Runs Have Historically Occurred as Result of Cyclic Changes IR 05000313/19980091998-12-21021 December 1998 Insp Repts 50-313/98-09 & 50-368/98-09 on 981025-1205.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support ML20196G4001998-11-19019 November 1998 Notice of Violation from Insp on 980913-1024.Violation Noted:Procedure 1104.032,Rev 51, FP Sys, Supplement 2, Surveillance Test of Diesel Fire Pump, Specified Limit on Max Coolant Temp Which Was Inconsistent Temp Set in Manual IR 05000313/19980081998-11-19019 November 1998 Insp Repts 50-313/98-08 & 50-368/98-08 on 980913-1024. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000313/19980191998-11-11011 November 1998 Insp Repts 50-313/98-19 & 50-368/98-19 on 981019-22.No Violations Noted.Major Areas Inspected:Exposure Controls, Control of Radioactive Matls & Contamination,Surveying & Monitoring & QA Oversight of Radiation Protection Program IR 05000313/19980201998-10-27027 October 1998 Insp Repts 50-313/98-20 & 50-368/98-20 on 981019-22.No Violations Noted.Major Areas Inspected:Operational Status of Licensee Emergency Preparedness Program IR 05000313/19980071998-10-15015 October 1998 Corrected Pages to Insp Repts 50-313/98-07 & 50-368/98-07 on 980925.Typo Was Identified in Numbering of Insp Followup Sys Closed Items IR 05000368/19983011998-10-14014 October 1998 NRC Operator Licensing Exam Rept 50-368/98-301 for Test Administered on 980831-0904 ML20154H0581998-10-0808 October 1998 NRC Operator Licensing Exam Repts 50-313/98-302 & 50-368/98-302 for Tests Administered on 980914-18.Overall, Operator License Applicants Demonstrated Good Performance & Use of Good Communication Practices,As Well as Peer Checks ML20153H2461998-09-25025 September 1998 Insp Repts 50-313/98-07 & 50-368/98-07 on 980802-0912.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000313/19980161998-09-15015 September 1998 Insp Repts 50-313/98-16 & 50-368/98-16 on 980831-0904.No Violations Noted.Major Areas Inspected:Testing & Maintenance,Protected Area Barrier & Detection Aids, Compensatory Measures & Security Sys Power Supply IR 05000313/19980111998-09-0303 September 1998 Insp Repts 50-313/98-11 & 50-368/98-11 Has Been Canceled.No Other Rept Will Be Issued IR 05000313/19980151998-09-0202 September 1998 Insp Repts 50-313/98-15 & 50-368/98-15 on 980818-21.No Violations Noted.Major Areas Inspected:Licensee Performance & Capabilities During full-scale,biennial Exercise of Emergency Plan & Implementing Procedures IR 05000313/19980061998-08-18018 August 1998 Insp Repts 50-313/98-06 & 50-368/98-06 on 980621-0801. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20237C9271998-08-18018 August 1998 Notice of Violation from Insp on 980621-0801.Violation Noted:Between 970601 & 980709,four Unit 1 Sros,Five Unit 2 Sros,One Unit 1 RO & Five Unit 2 ROs Resumed Activities Authorized by License W/O Performing RO or SRO Functions IR 05000313/19980051998-07-16016 July 1998 Insp Repts 50-313/98-05 & 50-368/98-05 on 980510-0620.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support ML20248J5751998-06-0404 June 1998 Notice of Violation from Insp on 980329-0509.Violation Noted:Licensed Senior Reactor Operators Completing Listed Form Did Not Identify That Two Craftsmen Were Signed in on Hold Card 98-1-0364 IR 05000313/19980041998-06-0404 June 1998 Insp Repts 50-313/98-04 & 50-368/98-04 on 980329-0509. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20216D2521998-05-11011 May 1998 Errata to Insp Repts 50-313/98-12 & 50-368/98-12 ML20247K0301998-05-0808 May 1998 Insp Repts 50-313/98-14 & 50-368/98-14 on 980427-0501. Violations Noted.Major Areas Inspected:Access Authorization, Alarm Stations,Communications,Access Control of Personnel & Packages & Vehicles ML20247K0261998-05-0808 May 1998 Notice of Violation from Insp on 980427-0501.Violation Noted:On 980430,inspector Determined That Computer Controlled Intrusion Detection Sys Failed to Provide Audible Alarm Signal Upon Recognizing Unauthorized Access Attempt ML20217A9231998-04-17017 April 1998 Notice of Violation from Insp on 980215-0328.Violation Noted:Licensee Failed to Update Radiological Info Posting at Entrance of HPSI Pump Room a to Reflect Results of Radiological Surveys Performed Between 980221 & 0302 ML20217A9351998-04-17017 April 1998 Insp Repts 50-313/98-03 & 50-368/98-03 on 980215-0328. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000313/19980131998-04-14014 April 1998 Insp Repts 50-313/98-13 & 50-368/98-13 on 980330-0403. Violations Noted.Major Areas Inspected:Review of Radiation Protection Program Focussing on Unit 1 Refueling Outage Activities ML20236L5221998-04-13013 April 1998 Notice of Violation from Investigation on 970916-980210. Violation Noted:Mj Talley Deliberately Documented Radiation & Contamination Survey Results for Areas Which Were Not Surveyed ML20217N2711998-04-0202 April 1998 Notice of Violation from Insp on 980302-11.Violation Noted: Engineering Technique Specification Sheet Etss 4 Instructed Outage 2P98 Eddy Current Analysts to Use Phase Rotation Setting Inappropriate for Plus Point Probe ML20217N3021998-04-0202 April 1998 Insp Repts 50-313/98-12 & 50-368/98-12 on 980302-11. Violations Noted.Major Areas Inspected:Maint & Engineering ML20248L6321998-03-18018 March 1998 Notice of Violations from Insp on 971027-31 & 1110-14. Violations Noted:Activities Affecting Quality Were Not Accomplished IAW Procedure 1000.028 ML20216B8621998-03-10010 March 1998 Notice of Violation from Insp on 980104-0214.Violation Noted:Instrumentation & Control Technicians Failed to Remove Three Jumpers Before Restoring Reactor Protection Sys Channel C to Svc ML20216B8751998-03-10010 March 1998 Insp Repts 50-313/98-02 & 50-368/98-02 on 980104-0214. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20202E3401998-02-0606 February 1998 Insp Repts 50-313/97-21 & 50-368/97-21 on 971027-31 & 1110- 14.Violations Noted.Major Areas Inspected:Engineering & Plant Support.Nrc Identified Fire Barrier Deficiency & Licensee Took Promp Compensatory Actions as Required ML20202E3201998-02-0606 February 1998 Notice of Violation from Insp on 971027-31 & 1110-14. Violation Noted:As of 911123,procedure 1010.002, Transient History/Transient Cycle Logging, Was Inappropriate to Circumstances IR 05000313/19980991998-02-0404 February 1998 SALP Repts 50-313/98-99 & 50-368/98-99 for Period of 970707-980103 IR 05000313/19970081998-01-23023 January 1998 Insp Repts 50-313/97-08 & 50-368/97-08 on 971123-980103.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support PNO-IV-98-001A, on 980105,plant Shutdown When Heavy Rains Caused Accumulation of Debris at Circulating & Svc Water Intake Structure.Debris Damaged Some Intake Structure Components.Repairs to Intake Components Completed on 9801091998-01-13013 January 1998 PNO-IV-98-001A:on 980105,plant Shutdown When Heavy Rains Caused Accumulation of Debris at Circulating & Svc Water Intake Structure.Debris Damaged Some Intake Structure Components.Repairs to Intake Components Completed on 980109 1999-09-01
[Table view] |
See also: IR 05000313/1978016
Text
,
U. S. NUCLEAR REGULATORY COMMISSION
(~')
0FFICE OF INSPECTION AND ENFORCEMENT
REGION IV
Report Nos. 50-313/78-16
50-368/78-24
Docket Nos. 50-313 License No. DPR-51
50-368 Construction Permit No. CPPR-89/
Facility Operating License NPF-6
Licensee: Arkansas Power and Light Company
P. O. Box 551
Little Rock, Arkansas 72203
Facility Name: Arkansas Nuclear One (AN0), Unit Nos. 1 and 2
Inspection At: ANO Site, Russellville, Arkansas
Inspection Conducted: September 25 - October 22, 1978
0 / J .
i
Inspectors: :1' N/V k M //hr / A>/ N//
'T. F. Westerman,-Reactor Inspector Date '
/ ,Y k ,ea /dh/77
" R. G. Spangler,LReactor Inspector (Intern) Date
Approved By: hG. L. W. <--/h h
Madsen, Chief, R;tetor Operations and
/o/-3//78_
Da'te
Nuclear Support Branch
Inspection Sunmary
Inspection During Period of September 22 through October 22, 1978 (Report
No. 50-313/ 78-16)
Areas Inspectg: Routine, unannounced inspection of plant operations. The
inspection involved 17 inspector-hours on-site by cne NRC inspector.
Results: Within the one area inspected, one infraction relative to jumpers /
bypasses was identified (DETAILS, paragraph 3).
Irspection During Period of September 22 through October 22, 1978 (Report
No. 50-368/78-24)
Areas Inspected: Routine, announced inspection of the startup program; the
event of September 16, 1978; and license conditions for Modes 1 and 2
operation. The inspection involved 36 inspector-hours on-site by the
resident inspector.
Resul t_s : Within the three areas inspected, no items of noncompliance were
identified. "f 81'319 0065,
a
'
.
-2-
DETAILS
..3
1. Persons Contacted
Arkansas-Power & Light Company Employees
G. H. Miller, Acting ANO Plant Manager
L. Alexander, QC Engineer
J. R. Anderson, Assistant Production Startup Supervisor
B. A. Baker, ANO-2 Operations Supervisor
R. L. Bata, QA Engineer '
T. N. Cogburn, Nuclear Engineer
E. C. Ewing, Production Startup Supervisor
D. R. Hamblin, QC Engineer
T. Holcomb, Scheduler '
P. Jones, Maintenance Supervisor
S. M. Strasner, QC Engineer
B. A. Terwilliger, Supervisor Plant Operations
R. Elder, Instrument Supervisor
J. Robert'on,
s ANO-1 Operations Supervisor
T. Ennis, Licensing
S. Petzel, Licensing
D. Williams, Licensing Manager
F. Foster, Mechanical Maintenance Supervisor
G. Bruss, ANO-2 Shift Supervisor
M. Stroud, Electrical Maintenance Supervisor
Bechtel Employee
R. Ramey, Bechtel Startup Engineer
2. Plant Status
Unit 1
Steady state 100% power operation.
Unit 2
Post core hot functional testing is in progress. Problems have been
encountered in performing the flow coast down test due to the malfunction
of a D/P cell across the reactor coolant pumps. Repair may require a
plant cooldown. Estimated criticality date is now the week of
November 13.
'
3. Review of Plant Operations (Unit 1)
The inspector conducted a review of plant operations by:
a. Performing a review of plant logs and data sheets for the quarterly
period of July through September; and
<
,
-- - - , ,
. . . . . .
'
.
-3- i
b. conducting a tour of selected areas within the plant to
observe general housekeeping and to verify selected component
configurations.
'
During the review of plant logs and data sheets, the inspector found
that bypass tag numbers 77-121-1 and 77-121-2 annotated on Bypass /
Jumper log sheet No. 320 had not been verified by an individual on
their removal'on March 15, 1978. Procedure 1005.04, Control and Use
of Bypasses and Jumpers, in paragraph 6.1.6, requires the initials of
not only the individual removing the tag but also a second individual
to verify the removal. 'The failure to properly verify the removal of .
the above tags as required by procedure 1005.04 is contrary to Technical
Specification 6.8.1 and constitutes an ' item of noncompliance at the
infraction level.
Within the remaining areas of the inspection, the inspector identified
several minor discrepancies that were corrected and discussed with
licensee representatives. No further items of noncompliances or
deviations were identified.
4. License Conditions Unit 2 for' Modes'1 and 2 (Unit 2)
The inspector reviewed the conditions identified in Attachment 2 to
Amendment No. 1 of NPF-6. The status is as follows:
a. Mode 2 (Initial Criticality)
(1) Startup Punchlist Items
The list has been reduced to the following systems:
PlantProtectiveSystem(1)
Air and Gas Radiation Monitors (1)
Liquid Radwaste System (1)
(2) Preoperational Tests
Preoperational Test 2.083.01, Main Steam Supply and Safety
Relief Valves, has been completed. RIV's review of test
data is not complete.
(3) Outstanding Startup Program Test Deficiencies
The RIV review of test deficiencies is not complete.
(4) Unit Load Transient Test 2.800.01, Appendix U
i Revision 1 to this procedure was issued September 27, 1978.
This issue is considered closed.
i
a
.. . . ~ .
,
'
.
-4-
(5) Main Feedwater Line Break Witnin Containment Piping
Penetration Room
Required design changes are scheduled to be coupleted by
October.
(6) Radiation Protection
Calibration of radiation protection equipment is still in
progress. Estimated completion date is October 29, 1978.
(7) Hanger Installation
Three hangers remain to be installed and work is in progress.
(8) Independent DC Power Supplies for the Series Containment
Penetration Breakers
The Design Change Package (DCP-638) that installed this
design change has been completed by Job Order 5450 on
August 29, 1978. This issue is considered closed.
(9) Discrepancies in Facility Operating Procedures
A permanent change to 2304.92 through 95 was being prepared
to provide for comparison of the addressable CPC constants
before and after testing. This is the only discrepancy
remaining.
(10) Hydrogen Purge System Test
This issue remains unresolved and the necessity for maintain-
ing this system is currently under review by NRR.
(11) Low Pressure Safety Injection Pump Motor Failure
,
This issue was closed in IE Inspection Report 50-368/78-23,
paragraph 14.d.
'
(12) Loose Part in the Safety Injection System
The licensee had initially reported that during repair of
valve SI-18 a pin was found to be missing. Subsequently,
during discussions with the maintenance personnel involved,
the licensee determined that the missing pin had not been
l
reinstalled during earlier maintenance activities. Actions
I have been taken by the licensee to provide instruction to
I the maintenance personnel involved to prevent recurrence.
l This issue is considered closed.
,
, -.. _ .. _..
'
.
-5-
b. Mode l'(Power Operation)
..
(1) Startup Punchlist Items
The following systems have outstanding startup punchlist
items which affect their operability.
- Control Room H&V (1)
Miscellaneous-H&V (1) .
FeedwaterSystem(1) ;
'
Fuel Pool and Auxiliaries (6).
Waste Gas System (1)
Solid Radiation Waste System (1)
Main Steam System (2) '
(2) CESEC Code' Instrumentation
i
The instrumentation for verification of the CESEC Code has
been obtained. The inspector will verify its installation
prior to Mode 1. >
There were no items of noncompliance or deviations identified during
the inspection of this item.
5. September -16, 1978 Incident (Unit 2)
During the period of this resident inspection report, a special
inspection was conducted of the September 16, 1978 incident involving
initiation of the Unit 2 Engineered Safety Feature Systems and spray
down of the Unit No. 2 containment building. (SeeIEInspectionReport
No. 50-368/78-25.)
Subsequent to this inspection, the licensee had proposed the following
preliminary plant changes and testing with respect to the instrument
inverters 2Y11, 2Y13, 2Y22 and 2Y24.
a. The input circuitry associated with fuse FU-2 which was '
found blown in 2Y24 is to be verified to be in accordance with
the vendor's recommendations for each inverter,
b. The current and voltage pots associated with the static transfer
switch are to be adjusted to their extreme position on each
inverter, i .e. , 185-190 amps vice the present nominal 154 amps on
overcurrent, and 20-30 volts vice the present 84 volts on under-
voltage. The licensee stated that the current setting of 190 amps
should cause .the inverter to go 'to 0 volts output as the result of
the saturation of the inverter output transformer.
- _
. . ~ . . - = ,
f
i
-6-
c. Each inverter is to be tested for the following:
(1) Operation on their respective DC bus with the normal
rectified 480 volt AC input de-energized.
(2) Tripping of the undervoltage coil associated with each
of the 480 volt essential buses. This would allow the
emergency diesels to start and assume the load on each
essential bus.
(3) De-energizing the power to the DC bus battery charger and
cycling of the breaker associated with the 480 volt AC
input.
(4) Determine if transfer switch operation does occur with
energization of the battery eliminator circuits associated
with the Reactor Trip Switchgear. This circuit draws
approximately 200 amps of starting current.
(5) Perform a load test of each inverter and verify appropriate
settings.
No items of noncompliance or deviations were identified during the
inspection of this item.
6. Pc c
o Core Hot Functional Test (Unit 2)
.,
Tht: inspector reviewed the Test Director's Log for the period of
September 11, 1978 through October 12, 1978. This log provides a
chronological record of the post core hot functional test program.
The inspector also reviewed the master sequence document 2.650.01
for the post core hot functional test which was in progress.
-
No items of noncompliance or deviations were identified.
7. Exit Meetings (Units 1 and 2)
Exit meetings were conducted on September 29, October 11 and
October 20, 1978 with Mr. Terwilliger and other members of the plant
staff. The inspectors discussed the scope of the inspection and ,
summarized the inspection findings which are detailed in this report.
r
t