Responds to NRC Compliance Bulletin 87-002, Fastener Testing to Determine Conformance W/Applicable Matl Specs. Procedure Revs for Procurement,Receipt Insp & Testing Being Formulated & Evaluated Based on Recent Testing
ML20147D105
Person / Time
Site: Yankee Rowe
Issue date: 01/11/1988
From: Heider L
YANKEE ATOMIC ELECTRIC CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
FYR-88-06, FYR-88-6, IEB-87-002, IEB-87-2, NUDOCS 8801200058
Download: ML20147D105 (50)


Text

{{#Wiki_filter:V ( Tebphone (017) 877-81C0 TWX 710-380-7619 YANKEE ATOMIC ELECTRIC COMPANY y 1671 Worcester Road, Framingham, Massachusotts 01701 v January 11, 1988 FYR 88-06 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 I

References:

(a) License No. DPR-3 (Docket No. 50-29) (b) USNRC Compliance Bulletin 87-02, dated November 6, 1987

Subject:

Response to NRC Compliance Bulletin 87-02

Dear Sir:

The following information is provided in response to NRC Compliance Bulletin 87-02, "Fastence Testing to Determine Conformance with Applicable Material Specifications," Reference (b). Action Items 1.s and 1.b. "Fastener Receipt Inspection. Storage and Control Activities Common to any material procured for use in safety-related applications, fasteners are subjected to a rigorous On-Site Receipt Inspection Program. These inspectiot. are conducted in accordance with an approved plant procedure which contains a minimum required sampling plan, equivalent to an Acceptable Quality Level 11 (modified). During the receipt inspection process the following characteristics are considered: Vendor Compliance with Shipping Instructions Indication of Shipping Damage Acceptability of Container Marking Adequacy of Packaging Verification of Material Origin Proper Identification and Marking Physical Properties Indication of Fraudulent Practices Workmanship Quality Documentation Review to Purchase Order, Material Specification, etc. (including CMTRs and C of Cs as required) DO /l ,l 1

l United States Nuclear Regulatory Commission January 11, 1988 Attention: Mr. Morton B. Fairtile Page 2 FYR 88-06 l l Following an acceptable receipt inspection, safety-related fasteners are segregated into bins by size and purchase order number. In addition, each storage bin containe a material identification tag which identifies the contents of each bin. The material identification tag is utilized to maintain traceability and contains the following information: Item Description Fbterial Purchase Request Number Safety Classification of Component Heat Number (when applicable) Serial or Mark Number (when applicable) Supplier or Manufacturer Date Received Job Order Number (when applicable) ANSI Level of Storage Shelf Life (if applicable) Once issuance of the fasteners is required, a Material Issue Slip (HI slip) is generated. This slip maintains traceability of the stock when removed from storage and documents the following information: Date Job Number Job Description Material Purchase Request Number Description of Material (type, serial number, or heat number, as applicable) Quantity, Size, or Amount Removed Stock Code Number Person Drawing Material from Storage Department Material is Issued To Receipt inspection and traceability of threaded rod are accomplished similarly with the exception of its storage. Since threaded rod is too large to store in bins, each rod (or bundle of rods) is affixed with a material identification tag containing the same information as the smaller fasteners. When threaded rod is issued from stock and subdivided into several sections, marking from the original length of rod is transferred to each section to ensure traceability. Issuance of the threaded rod is accomplished by the same manner as the smaller fasteners (i.e., material issue slip generation). Action Items 2 and 3 Mith participation from the Resident NRC Inspector, plant personnel Sci 3cted a sample stock of safety-related and non-nuclear safety fasteners and nuts. Since the stock of non-nuclear safety nuts were unmarked and purchased without certifications, as requested by the Resident NRC Inspector, the nuts selected for testing included only safety-related samples.

{' s e United States Nuclear Regulatory Commission January 11, 1988 FYR 88-06 Page 3 Action Item 4 As required by Action Item 4, the fasteners and nuts selected for testing were subjected to mechanical and chemical analysis by a qualified laboratory in accordance with the requirements of the fastener or nut material specification grade and class. Mechanical and chemical testing performed consisted of the following: Chemical and Hardness Testing of all (20) Safety-Related Nuts Tensile Strength, Yield Strength Elongation, Hardness, and Chemical Analysis of all (10) Safety-Related Fasteners Tensile Strength, Hardness, Yield Strength (where applicable), and Chemical Analysis of all (10) Non-Nuclear Safety Fasteners In addition as required by Action Item 4, each sample was tagged with an identification number. These numbers are contained in Attachments 1 and 2. Action Item 5 As required by Action Item 5, the results of all preliminary testing is contained in Attachment 2. The testing of the (40) samples yielded one non-nuclear safety fastener and one safety-related nut which did not meet the material specification tolerances. An evaluation of the safety significance for the out-of-tolerance fasteners has been performed and is contained in Attachment 3. Additional testing of nuts from the same heat number as the out-of-tolerance nut will be performed. This testing will include proof load testing performed in accordance with ASTM Specification A370, S14. At that time safety significance and limiting application will be determined. The results of the proof load testing as well as the safety significance and application limits will be provided by March 11, 1988. Until the final evaluation is completed, the material in question will be placed on hold. In addition, to determine the extent of nonconforming fasteners from this vendor, further sampling and testing are being conducted. The results of this testing will be provided by March 11, 1988. Action Item 6 Procedure revisions for procurement, receipt inspection, and testing are being formulated and evaluated based on the results of the recent testing. The necessary changes will be reported by March 11, 1988, i l l

t United States Nuclear Regulatory Commission January 11, 1988 FYR 88-06 Page 4 We trust that you will find this submittal satisfactory. However, if you have any questions, please contact us.- Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY L. H. Holder Vice President and Manager of Operation LH/15.419 Attachments COMMONWEALTH OF MASSACHUSETTS) )ss MIDDLESEK COUNTY ) Then personally appeared before me, L. H. Heider, who, being duly sworn, did state that he is Vice President and Manager of Operations of Yankee Atomic Electric Company, that he is duly authorized to execute and file the foregoing document in the name and on the behalf of Yankee Atomic Electric Company and that the statements therein are true to the best of his knowledge and belief. vM M Robert H. Groce Notary Public l My Commission Expires August 29, 1991 l cc: USNRC Region I USNRC Resident Inspector - YNPS

4 i Fastener Testing Data Sheet

  • Sample IDH:

YR87-02-1SR-F Fastener

Description:

1/2-13 UNC x 2" hex bolt 85-60/A11 i Description of Sample Stock Location: Stores O/A Storage Location: V85 l Material Specification as Documented by Licensee Records: l SA193-B7 l Head Marking (Specification and Manufacturer): 87 Cardinal L7 C U

    • Class / Procurement Levels 1

SC 1 Level C ANSI N45.2.2 l General Plant Application (e.g., Pressure Boundary, Structural) Pressure Boundary Vendor: Cardinal Industrial Products Corp. 3873 West Oquendo Las Vegas, NV 89118 f ( OA Requirements Imposed on Vendor Provide C of C to PO Apply ASME approved O/A Program Licensee Representatives Signature Ed0u !s

llvab, Date /

4'd

  • The sample IDM shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

l 4 l Fastener Testing Data Sheet

  • Sample IDW:

YR87-02-2SR-F Fastener

Description:

3/4-10 x 4" hex bolt ES-60/A11 Description of Sample Stock Location: Stores O/A Storage Location: V87 Material Specification as Documented by Licensee Records: 5A193-B7 Head Marking (Specification and Manufacturer): 87 C 7-C-12

    • Class / Procurement Level SC 1 Level C ANSI N45.2.2 General Plant Application (e.g.,

Pressure Boundary, Structural) Pressure Boundary Vendor: Cardinal Industrial Products Cor p. 3873 West Oquendo Las Vegas, NV 89118 OA Requirements Imposed on Vendor: Provide C of C to PO Apply ASME approved O/A Program l Licensee Representatives l Signature s/f / /t n Date / 88 p j i

  • The sample ID# shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

v i Fastener Testing Data Sheet

  • Sample ID4 YR87-02-3SR-F Fastener

Description:

7/8-9 x 1-1/2" hex bolt 85-60/A11 Description of sample Stock Location: Stores O/A Storage Location: V88 Material Specification as Documented by Licensee Records: SA193-B7 Head Marking (Specification and Manufacturer): B7 C C L7

    • Class / Procurement Levels i

SC 1 l Level C ANSI N45.2.2 I I General Plant Application (e.g., Pressure Boundary, Structural) Pressure Boundary l i Vendor: Cardinal Industrial Products Corp. I 3873 West Oquendo Las Vegas, NV 89118 OA Requirements Imposed on Vendor: j Provide C of C to PO Apply ASME approved O/A Program Licensee Representatives Signature f? h _Lu s/GkB y 3 Date

  • The sample ID# shall have a prefix that contains the licensee facility initials.
    • 1f applicable, please provide an explanation for your classification system.

6 o

  • Fastener Testing Data Sheet
  • Sample ID#

YR87-02-4SR-F Fastener

Description:

1/4-20 x 1-1/2" hex bolt 80-90/A44 l Description of Sample Stock Location: I Stores O/A Storage Location: V82 f Material Specification as Documented by Licensee Records: l SA193-68 GR B7 Head Marking (Specification and Manufacturer): 1 B7 I C A1

    • Class / Procurement Level Safety Class Level B ANSI N45.2.2 General Plant Application (e.g.,

Pressure Boundary, Structural) Pressure Boundary Vendor: Commercial Fasteners Corp. 18-35 38th Street Long Island City, NY 11105 OA Requirements Imposed on Vendor Provide C of C to Material Spec. Licensee Representative: l Siqnature Khh,/ huby Date 1/6 b6'

w
  • The sample ID# shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your j

classification system. i

- v 4 Fastener Testing Data Sheet

  • Sample IDW:

YR87-02-SSR-F Fastener

Description:

3/8-16 x 1-1/4" hex bolt 85-50/A5 Description of Sample Stock Location: Stores O/A Storage Location: V84 Material Specification as Documented by Licensee Records: A193 B7 Head Marking (Specification and Manufacturer): T B S B7

    • Class / Procurement Level SC 1 Level D ANSI N45.2.2 General Plant Application (e.g.,

Pressure Boundary, Structural) Pressure Boundary Vendor: Alloy Pipe & Fittings Cor5 171 Murphy Road Hartford, CT OA Requirements Imposed on Vendor Provide C of C to PO Licensee Representative: b3 Da te //G /6W Signature F-(U ' -, R 7 c

  • The sample ID# shal have a prefix that contains the licensee facility initials.

i

    • If applicable, please provide an explanation for your classification system.

l I i

4 Fastener Testing Data Sheet

  • Sample ID#:

YR87-02-6SR-F Fastener

Description:

5/8-11 x 4" hex bolt 80-60/A1 Description of Sample Stock Location: Stores O/A Storage Location: V86 Material Specifica* ion as Documented by Licensee Records: A193 B7 Head Marking (Specification and Manufacturer): I B S B7

    • Class / Procurement Level Safety Class Level B ANSI N45.2.2 General Plant Application (e.g.,

Pressure Boundary, Structural) Pressure Boundary Vendor: New England Bolt Co. 9 Charlton Street Everett, MA 02149 OA Requirements Imposed on Vendor Provide C of C to Material Spec. Licensee Representative: Signature 2 d 0g,ds $hhph Da te //6 /0e3 + (/

  • The sample IDM shall have a prefix that contains the licensee facility initials.
    • 1f applicable, please provide an explanation for your classification system.

) i l l 1 1

r-v 0 Fastener Testing Data Sheet

  • Sample ID4:

YR87-02-75R-F Fastener

Description:

5/8-11 x l-3/4" hex bolt 81-30/A50 Description of Sample Stock Location: Stores O/A Storage Location: Level B Material Specification as Documented by Licensee Records: A193 B7 Head Marking (Specification and Manufacturer): B7 T B

    • Class / Procurement Level Safety Class Level C ANSI N45.2.2 General Plant Application (e.g.,

Pressure Boundary, Structural) Pressure Boundary Vendor: New England Bolt Co. 9 Charlton Street Everett, MA 02149 OA Requirements Imposed on Vendor Provide C of C to Material Spec. Licensee Representative Signature F#b/g d i d I_1 g h,_ D a t e _ ; /e-M d s I

  • The sample IDM shal have a prefix that contains the licensee facility initials.
    • i applicable, please provide an explanation for your classification system.

Fastener Testing Data Sheet

  • Sample ID#:

YR87-02-8SR-F Fastener Descriptions 1/4-20 y 1" hex bolt 85-80/A9 Description of Sample Stock Location: Stores O/A Storage Location: V82 f Material Specification as Documented by Licensee Records: l l SA193-B7 Head Marking (Specification and Manufacturer): B7 C Al I

    • Class / Procurement Level Safety Class Level C ANSI N45.2.2 General Plant Application (e.g.,

Pressure Boundary, Structural) l Pressure Boundary l Vendor: Cardinal Industrial Products Corp. 3873 West Oquendo Las Vegas, NV 89118 OA Requirements imposed on Vendor 1 Provide C of C to PO l Licensee Representative Signature E S-Os Mhh Date / 4 cf' I l \\

  • The sample ID# shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

I Fastener Testing Data Sheet

  • Sample IDM YR87-02-95R-F Fastener

Description:

7/8-9 threaded rod 78-110/A29 Description of Sample Stock Location: Stores O/A Storage Location: Storeroom Material Specification as Documented by Licensee Records: A193 B7 Head Marking (Specification and Manufacturer): A

    • Class / Procurement Level SC 1 Level D ANSI N45.2.2 General Plant Application (e.g.,

Pressure Boundary, Structural) Pressure Boundary Vendor New England Bolt Co. 9 Charlton Street Everett, MA 02149 OA Requirements Imposed on Vendor: Chemical & Physical Test Report C of C to Material Spec. Licensee Representative hhuh Date_j/d/dc? Signature F # b /;f . /g /

  • The sample IDM shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

~ 1 I Fastener Testing Data Sheet

  • Sample IDN:

YR87-02-10SR-F Fastener

Description:

1/2-13 threaded rod 81-70/A8 Description of Sample Stock Location: Stores O/A Storage Location: Warehouse Material Specification as Documented by Licensee Records: A193-77A GR B7 Head Marking (Specification and Manufacturer): None

    • Class / Procurement Level:

Safety Class Level D ANSI N45.2.2 General Plant Application (e.g., Pressure Boundary, Structural) Pressure Boundary Vendor NPS Industries 300 Harmon Meadow Blvd. Seacaucus, NJ 07094 QA Requirements Imposed on Vendor: Chemical & Physical Test Report Licensee Representative Signature 3:? h_._f _ - . r.I. rji Date / h [fM' /

  • The sample IDn shall have a prefix that contains the licensee

) facility initials.

    • 1f applicable, please provide an explanation for your 4

classification system. ) l l

v s Fastener Testing Data Sheet

  • Sample ID4:

YR87-02-1SR-N Fastener

Description:

1/2-13 hex nut 85-60/A11 Description of Sample Stock Location: Stores O/A Storage Location: V85 Material Specification as Documented by Licensee Records: SA194 2H Head Marking (Specification and Manufacturer): 2H

  • 4 Class / Procurement Level SC 1 Level D ANSI N45.2.2 General Plant Application (e.g.,

Pressure Boundary, Structural) Pressure Boundary Vendor: Cardinal Industrial Products Corp. 3873 West Oquendo Las Vegas, NV 89118 QA Requirements Imposed on Vendor: Provide C of C to PO Apply ASME approved O/A Program Licensee Representative Signature _ E d Ib, Da te //d /['d

  • The sample IDM shall have a prefix that con tains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

4 Fastener Testing Data Sheet

  • Sample IDM YR87-02-2SR-N Fastener

Description:

3/4-10 hex nut 82-90/A20 Description of Sample Stock Location: Stores O/A Storage Location: V28 Material Specification as Documented by Licensee Records: SA194 2H Head Marking (Specification and Manufacturer): 2H

    • Class / Procurement Level SC 1 Level D ANSI N45.2.2 General Plant Application (e.g.,

Pressure Boundary, Structural) Pressure Boundary Vendor: Cardinal Industrial Products Cr o. 3873 West Oquendo Las Vegas, NV 89118 j OA Requirements Imposed on Vendor Provide C of C to PO Apply ASME approved O/A Program Licensee Representatives ,f, a _ fd $8 Signature _ X 8~ LO q Date _/

  • The sample ID# shall tave a prefix that contains the licensee l

facility initials.

    • If applicable, please provide an explanation for your classification system.

l

Fastener Testing Data Sheet

  • Sample ID#:

YR87-02-3SR-N Fastener

Description:

7/8-9 hex nut 81-70/A8 Description of Sample Stock Location: Stores O/A Storage Material Specification as Documented by Licensee Records: A194-78 GR 2H Head Marking (Specification and Manufacturer): 2H

    • Class / Procurement Levels SC 1 Level D ANSI N45.2.2 General Plant Application (e.g.,

Pressure Boundary, Structural) Pressure Boundary Vendor NPS Industries, Inc. 300 Harmon Meadow Blvd Secaucus, NJ 07094 OA Requirements Imposed on Vendor Provide C of C to Material Spec. Licensee Representatives hco u Signature F g Al be 1 ~ Date//h l86 a / /

  • The sample IDM shall have a prefix that contains the licensee facility initials.
    • 1f applicable, please provide an explanation for your classification system.

r-6 0 Fastener Testing Data Sheet

  • Sample ID#:

YR87-02-45R-N Fastener

Description:

1/4-20 hex nut 82-lOQ/A7 Description of Sample Stock Location: Stores O/A Storage Locaticn V82 Material Specification as Documented by Licensee Records: SA194-80 GR 2H Head Marking (Specification and Manufacturer): 2H

    • Class / Procurement Level SC Level B ANSI N45.2.2 General Plant Application (e.g.,

Pressure Boundary, Structural) Pressure Boundary Vendor: Commercial Fasteners 18-35 38th Street Long Island City, NY 11105 OA Requirements Imposed on Vendor Provide C of C to Material Spec. Licensee Representative Signature p (gf ( ult Date //6M8

  • The sample IDM shall ave a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

[ o' l Fastener Testing Data Sheet

  • Sample IDM YR87-02-5SR-N Fastener

Description:

3/8-16 hex nut 80-90/A51 Description of Sample Stock Location: Stores O/A Storage Location: V84 Material Specification as Documented by Licensee Records: A194 GR 2H Head Marking (Specification and Manufacturer): 2H

    • Class / Procurement Level:

SC 1 Level D ANSI N45.2.2 General Plant Application (e.g., Pressure Boundary, Structural) Pressure Boundary Vendor New England Bolt Co. 9 Charlton Street Everett, MA 02149 QA Requirements imposed on Vendor: j Chemical & Physical Test Report C of C to Material Spec. Licensee Representative Y{, Date //t; /68 Siqnature f d fjj r -{f I

  • The sample IDn shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

i I

Fastener Testing Data Sheet

  • Sample ID#:

YR87-02-6SR-N Fastener

Description:

5/8-11 hex nut 81-70/A8 Description of Sample Stock Location: Stores O/A Storage Location: V29 Material Specification as Documented by Licensee Records: A194 GR 2H Head Marking (Specification and Manuf4.turer): 2H

    • Class / Procurement Level:

SC 1 Level D ANSI N45.2.2 General Plant Application (e.g., Pressure Boundary, Structural) Pressure Boundary Vendor NPS Industries 300 Harmon Meadow Blvd. Seacaucus, NJ 07094 OA Requirements Imposed on Vendor: Provide C of C to Material Spec. Licenseo Representative: Signature _fW*kle{/o { hAk Date fM MW shall{havea f - p b prefix that contains the licensee

  • The sample IDM facility initials.
    • If applicable, please provide an explanation for your classification system.

1 o Attachment I Fastener Testing Data Sheet

  • Sample IDM YR87-02-75R-N Fastener Description S/8-11 hex nut 81-30/A50 t

Description of Sample Stock Location: Stores O/A Storage Location: Level B Material Specification as Documented by Licensee Records: A.94 GR 2H Head Marking (Specification and Manufacturer): 2H

    • Class / Procurement Level Safety Related Level C ANSI N45.2.2 General Plant Application (e.g.,

Pressure Boundary, Structural) Pressure Boundary Vendor New England Bolt Co. 9 Charlton Street Everett, MA 02149 OA Requirements Imposed on Vendor: Provide C of C to Material Spec. Licensee Representatives Signature W Ykt uh Date _//6 d' i

  • The sample IDM shall have a prefix that contains the licensee facility initials.

]

    • If applicable, please provide an explanation for your classification system.

I

i o t Fastener Testing Data Sheet

  • Sample IDM YR87-02-OSR-N Fastener

Description:

1/4-20 hex nut 82-100/A7 Description of Sample Stock Location: Stores O/A Storage Location: V82 Material Specification as Documented by Licensee Records: SA194-80 GR 2H Head Marking (Specification and Manu 'ac turer ) : 2H

    • Class / Procurement Levels Safety Class Level B ANSI N45.2.2 General Plant Application (e.g.,

Pressure Boundary, Structural) Pressure Boundary Vendor: Commercial Fasteners 18-35 38th Street Long Island City, NY 11105 OA Requirements imposed on Vendor: j Provide C of C to Material Spec. Licensee Representative: Signature -FA k hfIg ,L M b ib. Date / /d I## 5(,

  • Ihe sample IDH shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your j

classification system. I

i Fastener Testing Data Sheet

  • Sampla IDM YR87-02-95R-N Fastener

Description:

7/8-9 hex nut 81-70/A8 Description of Sample Stock Location: Stores O/A Storage Location: V29 Material Specification as Documented by Licensee Records: A194-78 GR 2H Head Marking (Specification and Manufacturer): 2H

    • Class / Procurement Levels SC 1 Level D ANSI N45.2.2 General Plant Application (e.g.,

Pressure Boundary, Structural) Pressure Boundary Vendor NPS Industries 300 Harmon Meadow Blvd. Seacaucus, NJ 07094 QA Requirements Imposed on Vendor Provide C of C to Material Spec. Licensee Representative Signature E k y;f ( !4_ Date y M f f 4The sample IDM shall have a prefix that contains the licensee facility initials.

    • If applicable, please provide an explanation for your classification system.

6 Fastener Testing Data Sheet

  • Sample ID#

YR87-02-10SR-N Fastener

Description:

1/2-13 hex nut Description of Sample Stock Location: Stores O/A Storage Location: V85 Material Specification as Documented by Licensee Records: SA194 2H Head Marking (Specification and Manufacturer): 2H

    • Class / Procurement Level SC 1 Level D ANSI N45.2.2 General Plant Application (e.g.,

Pressure Boundary, Structural) Pressure Boundary Vendor: Cardinal Industrial Products Corp. 3873 West Oquendo Las Vegas, NV 89118 OA Requirements Imposed on Vendor Provide C of C to PO Apply ASME approved O/A Program Lice.isee Representative ., u Y, d[As tb Date_//cid6 [ Signature. F_ O gp6b,

  • The sample ID# shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

e Fantener Testing Data Sheet t

  • Sample IDH:

YR87-02-lNNS-F Fastener

Description:

1/2-13 x 1-1/2 hex bolt Description of Sample Stock Location: Stores NNS Material Specification as Documented by Licensee Records: None Head Marking (Specification and Manufacturer): I BS A325

    • Class / Procurement Level None General Plant Application (e.g.,

Pressure Boundary, Structural) General Use Vendor: Misc. Industrial Suppliers OA Requirements Imposed on Vendor None Licensee Representative Signature N % $ t. LY Da teJ/G k8 ak

  • The sample ID4 shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your i

classification system.

i i O Fastener Testing Data Shoot

  • Sample ID4:

YR87-02-2NNS-F Fastener

Description:

1/2-13 x l-1/2 hex bolt Description of Sample Stock Location: Stores NNS Material Specification as Documented by Licensee Records: None Head Marking (Specification and Manufacturer): /NB\\

    • Class / Procurement Level None General Plant Application

'e.g., Pressure Boundary, Structural) General Use 1 Vendor: Misc. Industrial Suppliers OA Requirements Imposed on Vendor: None Licensee Representativet n_Y, r Yq A Date //c: W Signature it r-

  • The sample IDM shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

l 1 i l

0 Fastener Testing Data Sheet

  • Sample IDH:

YR87-02-3NNS-F Fastener Description 3/4-10 x 2-1/2 hex bolt Description of Sample Stock Location: Stores NNS Material Specification as Documented by Licensee Records: None Head Marking (Specification and Manufacturer): A325 S

    • Class / Procurement Level None General Plant Application (e.g.,

Pressure Boundary, Structural) General Use Vendor: Misc. Industrial Suppliers OA Requirements Imposed on Vendor: None Licensee Representative Signature g (3 Date /[6 [cfd'

  • The sample IDM shall have a prefix that contains the licensee facility initials.

j

    • If applicable, please provide an explanation for your classification system.

i 1 1 i

Fastener Testing Data Sheet

  • Sample ID4:

YR87-02-4NNS-F Fastener

Description:

1/2-13 x 2-1/2 hex bolt Description of Sample Stock Location: Stores NNS Material Specification as Documented by Licensee Records: None Head Marking (Specification and Manufacturer): l KS / \\

    • Class / Procurement Level:

None General Plant Application (e.g., Pressure Boundary, Structural) General Use Vendor: Misc. Industrial Suppliers OA Requirements Imposed on Vendor: None Licensee Representatives Signature 2-- - ( fa LU)g Date /f6 Q4 e 7 c

  • The sample ID# shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

6 Fastener Testing Data Sheet

  • Sample ID#:

YR87-02-5NNS-F Fastener

Description:

7/16-14 x 3-1/2 hex bolt Description of Sample Stock Location: Stores NNS Material Specification as Documented by Licensee Records: None Head Marking (Specification and Manufacturer): S S 5 / C \\

    • Class / Procurement Level:

None General Plant Application (e.g., Pressure Boundary, Structural) G9neral Use Vendor: Misc. Industrial Suppliers OA Requirements Imposed on Vendor: None Licensee Representative: 7 -- b4dh Date / 8 Signature M. - /w a .,~

  • The sample ID# shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

Fastener Testing Data Sheet

  • Sample IDH:

YR87-02-6NNS-F Fastener

Description:

5/16-18 x 5 hex bolt Description of Sample Stock Location: Stores NNS Material Specification as Documented by Licensee Records: None Head Marking (Specification and Manufacturer): /A\\

    • Class / Procurement Level:

None General Plant Application (e.g., Pressure Boundary, Structural) General Use Vendor: Misc. Industrial Suppliers j OA Requirements Imposed on Vendor None Licensee Representative Signature _ g [ khf s ula Date / 4'd' "y"f I

  • The sample ID# shall have a prefix that contains the licensee facility initials.
    • If applicable, pleace provide an explanation for your classification system.

1 1 4 i Fastener Testing Data Gheet

  • Sample IDH YR87-02-7NNS-F Fastener

Description:

1"-8 x 5-3/4 hex bolt Description of Sample Stock Location: Stores NNS Material Specification as Documented by Licensee Records: None Head Marking (Specificaticn and Manufacturer): J B7

    • Class / Procurement Level None General Plant Application (e.g.,

Pressure Boundary, Structural) General Use Vendor: Misc. Industrial Suppliers OA Requirements Imposed on Vendor None Licensee Representative Yp$h k,./Ab, f Date / fG b 6' Signature j *-t y

  • The sample IDM shall have a prefix that contains the licensee facilicy initials.
    • 1f applicable, please provide an explanation for your classification system.

i

r Fastener Testing Data Sheet

  • Sample ID#:

YR87-02-8NNS-F Fastener

Description:

1/2-13 x 5 hex bolt Description of Sample Stock Location: Stores NNS Material Specification as Documented by Licensee Records: None Head Marking (Specification and Manufacturer): l 5 / \\

    • Class / Procurement Level None General Plant Application (e.g.,

Pressure Boundary, Structural) General Use Vendor: Misc. Industrial Suppliers OA Requirements Imposed on Vendor: None Licensee Representative: Signature f , LL l< fb,, Date /

  1. cf
  • The sample ID# shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

6 0 Fastener Testing Data Sheet

  • Sample ID#1 YR87-02-9NNS-F Fastener

Description:

5/8-11 x 5 hex bolt Description of Sample Stock Location: Stores NNS Material Specification as Documented by Licensee Records: None Head Marking (Specification and Manufacturer): \\TH/ i

    • Class / Procurement Level:

None General Plant Application (e.g., Pressure Boundary, Structural) General Use Vendor: Misc. Industrial Suppliers OA Requirements Imposed on Vendor: None Licensee Representative hih Signature E" (< LL Date / cf

  • The sample ID# shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

l

Fastener Testing Data Sheet

  • Sample ID#

YR87-02-10NNS-F Fastener

Description:

5/8-11 x 4 hex bolt Description of Sample Stock Location: Stores NNS Material Specification as Documented by Licensee Records: None Head Marking (Specification and Manufacturer): 1 KS / \\

    • Class / Procurement Level:

None General Plant Application (e.g., Pressure Boundary, Structural) General Use Vendor: Misc. Industrial Suppliers OA Requirements Imposed on Vendor None Licensee Representative: bdb Date / 8 Signature /zjaQ5 --n c

  • The sample IDM shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an ex p l an o.t i on for your i

classification system. I

b Fastener Testing Data Sheet

  • Sample ID#:

YR87-02-11SR-N Fastener

Description:

1/2-13 x l-1/2 hex nut 85-60/All Description of Sample Stock Location: Stores O/A Storage Location: V85 Material Specification as Documented by Licensee Records: SA194 2H Head Marking (Specification and Manufacturer): 2H

  • Class /Procuremen t Level :

SC 1 Level D ANSI N45.2.2 General Plant Application (e.g., Pressure Boundary, Structural) Pressure Boundary Vendor: Cardinal Industrial Products Corp. 3873 West Oquendo Las Vegas, NV 89118 OA Requirements Imposed on Vendor: Provide C of C to PO Apply ASME Approved O/A Program Licensee Representatives Signature [ d

Jub, Date

/ 6 8 a k ( (

  • The sample ID# shall have a prefix that contains the licensee facility initials.
    • 1f applicable, please provide an explanation for your classification system.

l l

6 o' Fastener Testing Data Sheet

  • Sample ID#

YR87-02-12SR-N Fastener

Description:

1/2-13 hex nut 85-60/A11 Description of Sample Stock Location: Stores O/A Storage Location: V85 Material Specification as Documented by Licensee Records: SA194 2H Head Marking (Specification and Manufacturer): 2H

    • Class / Procurement Level:

SC 1 Level D ANSI N45.2.2 General Plant Application (e.g., Pressure 8cundary, Structural) Pressure Boundary Vendor: Cardinal Industrial Products Corp. 3873 West Oquendo Las Vegas, NV 89118 OA Requirements Imposed on Vendor: Provide C of C to PO Apply ASME Approved O/A Program Licensee Representatives Signature 'FMzd A dI t2th Date / 8 ~ {} { f

  • The sample ID# shall have a prefix that contains the licensee facility initials.
    • 1f applicable, please provide an explanation for your classification system.

6 O Fastener Testing Data Sheet

  • Samole ID#:

YR87-02-13SR-N Fastener

Description:

3/4-10 hex nut 82-90/A20 Description of Sample Stock Location: Stores O/A Storage Location: V28 Material Specification as Documented by Licensee Records: A194 GR 2H Head Marking (Specification and Manufacturer): 2H j

    • Class / Procurement Level Safety Class Level C ANSI N45.2.2 General Plant Application (e.g.,

Pressure Boundary, Structural) l Pressure Boundary Vendor: New England Dolt Co. 9 Charlton Street Everett, MA 02149 OA Requirements Imposed on Vendor l Provide C of C to Material Spec. Licensee Representative aYkkL4ft Date,/ /t: k 6 Signature Y# -- // s m 7 7

  • The sample IDH shall ve a prefix that contains the licensee i

facility initials. j

    • If applicable, please provide an explanation for your classification system.

i 4 Attachment i Fastener Testing Data Sheet

  • Sample ID#:

YR87-02-145R-N Fastener

Description:

1/2-13 hex nut 85-60/A11 Description of Sample Stock Location: Stores O/A Storage Location: VB5 Material Specification as Documented by Licensee Records: SA194 2H Head Marking (Specification and Manufacturer): 2H

    • Class / Procurement Level:

SC 1 Level D ANSI N43.2.2 General Plant Application (e.g., Pressure Boundary, Structural) Pressure Boundary Vendor: Cardinal Industrial Products Corp. 3873 West Oquendo Las Vegas, NV 89118 QA Requirements Imposed on Vendor: Provide C of C to PO Apply ASME Approved O/A Program Licensee Representative knWNbtYk 3 r- '/fS /d'd* Signature, W {tj Date

  • The sample IDM shall have a prefix that contains the licensee facility initials, j
    • If applicable, please provide an explanation for your classification system.

l i

a e o Fastener Testing Data Sheet

  • Sample ID4:

YR87-02-155R-N Fastener

Description:

7/16-14 hex nut 82-LOD /A16 Description of Sample Stock Location: Stores O/A Storage Location: V28 Material Specification as Documented by Licensee Records: A194 GR 2H Head Marking (Specification and Manufacturer): 2H

    • Class / Procurement Level:

Safety Class Level D ANSI N45.2.2 General Plant Application (e.g., Pressure Boundary, Structural) Pressure Boundary Vendor: New England Bolt Co. 9 Charlton Street Everett, MA 02149 OA Requirements Imposed on Vendor: Provide C of C to PC l Licensee Representative: Signature _ g [ do !.N;I[mb Date / IF / I

  • The sample ID# shall have a prefix that contains the licensee i

facility initials.

  • tif applicable, please provide an explanation for your classification system.

s o l i j Fastener Testing Data Sheet

  • Sample ID#:

YR87-02-16SR-N Fastener

Description:

5/16-18 hex nut 82-100/A7 Description of Sample Stock Location: Stores O/A Storage Location: V83 Material Specification as Documented by Licensee Records: SA194-80 GR 2H Head Marking (Specification and Manufacturer): 2H

    • Class / Procurement Level:

Safety Class Level B ANSI N45.2.2 General Plant Application (e.g., Pressure Boundary, Structural) Pressure Boundary Vendor: Commercial Fasteners 18-35 38th Street Long Island City, NY 11105 OA Requirements Imposed on Vendor: Provide C of C to Material Spec. Licensee Representative Signature Q0/1 d),w Da te _/ G d a a l '%f f

  • The sample ID4 shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

4 Fastener Testing Data Sheet

  • Sample ID#:

YR87-02-175R-N Fastener

Description:

1"-8 hex nut 85-60/A11 Description of Sample Stock Location: Stores O/A Storage Location: V89 Material Specification as Documented by Licensee Records: SA194 2H Head Marking (Specification and Manufacturer): 2H

  • Class /Procuremen t Level s SC 1 Level D ANSI N45.2.2 General Plant Application (e.g.,

Pressure Boundary, Structural) Pressure Boundary Vendor: Cardinal Industrial Products Corp. 3873 West Opuendo Las Vegas, NV 89118 OA Requirements Imposed on Vendor Provide C of C to PO Apply ASME Approved O/A Program Licensee Representative: [, ., tYs d[ht b Signature f v Date / 27

  • The sample IDM shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

a Fastener Testing Data Sheet

  • Sample ID#:

YR87-02-185R-N Fastener

Description:

1/2-13 hex nut 85-60/A11 Description of Sample Stock Location: Stores O/A Storage Location: V85 Material Specification as Documented by Licensee Records: SA194 2H Head Marking (Specification and Manufacturer): 2H

    • Class / Procurement Level:

SC 1 Level D ANSI N45.2.2 General Plant Application (e.g., Pressure Boundary, Structural) Pressure Boundary Vendor: Cardinal Industrial Products Corp. 3873 West Oquendo Las Vegas, NV 89118 OA Requirements Imposed on Vendor Provide C of C to PO Apply ASME Approved O/A Program Licensee Representatives Albt Da te,/ 8 Signature M u (L

  • The sample ID# shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

Fastener Testing Data Sheet i

  • Sample ID#:

YR87-02-195R-N Fastener Description 5/8-11 hex nut 81-30/A50 Description of Sample Stock Location: Stores O/A Storage Location: Level B Material Specification as Documented by Licensee Records: A194 GR 2H Head Marking (Specification and Manufacturer): 2H

    • Class / Procurement Levels Safety Related Level C ANSI N45.2.2 General Plant Application (e.g.,

Pressure Boundary, Structural) Pressure Boundary Vendor: New England Bolt Co. 9 Charlton Street Everett, MA 02149 OA Requirements Imposed on Vendor Provide C of C to Material Spec. Licensee Representative: Signature _ g 6 G LC L Date / ; 8

  • The sample IDH shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

4 0 Fastener Testing Data Sheet

  • Sample ID#:

YR87-02-20SR-N Fastener

Description:

5/8-11 hex nut 81-30/A50 Description of Sample Stock Location: Stores O/A Storage Location: Level B Material Specification as Documented by Licensee Records: A194 GR 2H Head Marking (Specification and Manufacturer): 2H

    • Class / Procurement Level Safety Related Level C ANSI N45.2.2 General Plant Application (e.g.,

Pressure Boundary, Structural) Pressure Boundary Vendor: New England Bolt Co. 9 Charlton Street Everett, MA 02149 OA Requirements Imposed on Vendor: Provide C of C to Material Spec. j Licensee Representative Signature _ g] ff y C 4 Date / ~f f

  • The sample IDM shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

)

Attachtsnt 2 Data Summary SCFETY RELATED FASTEERS Mechanical Analysis Chemical Analysis 1 ID # Hardness UIS O.27. YS C Ph P S Si Mo Cr YR-87-02-1SR-F FNC-27.0 130.5 KSI 115.8 KSI .40 .82 .030 .021 .21 .17 1.00 YR-87-02-2SR-F FfE-33.0 157.3 KSI 150.3 KSI .43 .88 .021 .010 .25 .15 1.07 YR-87-02-3SR-F FRC-33.5 150.0 KSI 136.9 KSI 40 .81 .023 .012 .23 .16 0.95 YR-87-02-45R-F FRC-31.5 143.8 KSI 138.0 KSI .39 .78 .025 .019 .27 .17 1.03 YR-87-02-55R-F FHC-35.0 154.2 KSI 145.7 KSI .38 .79 .010 .017 .18 .19 0.91 YR-87-02-6SR-F FOC-31.5 152.1 KSI 138.0 KSI .40 .83 .014 .016 .25 .18 1.03 YR-87-02-7SR-F FEC-28.5 133.5 KSI 121.7 KSI .36 .84 .017 .013 .24 .20 0.98 YR-87-02-OSR-F FOC-31.0 144.6 KS1 133.5 KSI .40 .85 .011 .013 .23 .21 0.95 YR-87-02-95R-F FEC-33.0 252.6 KS1 135.8 KSI .45 .89 .023 .028 .28 .18 1.10 YR-87-02-10SR-F FRC-31.0 143.1 KSI 126.2 KSI .39 .95 .010 .023 .24 .21 1.04 Note: UTS-ultimate tensile strength; YS yield strength; C-carbon; Mn-Manganese; P--Phosphorus; S-Sulfur; Si-Silicon; Mo-Molybdenum; Cr-Ctromium. The elements listed apply to ASTM A193 87 or SA193 87 material. The elements to be reported for other materials tested, stull conform to those reported in the applicable material specification. Properties found out of specification shall be noted with an asterisk.

9 Attachrrent 2 Data Summary POJ SffETY RELATED FASTEIERS firhanical Analysis Chemical Analysis 2 ID # Hardness UTS O.27. YS C Mn P S Si Mo Cr YR-87-02-1ME-F FfE-29.0 139.5 KSI .42 .80 .004 .013 .20 .02 .03 YR-874T2-2M6-F FfE-33.0 156.5 KSI 147.8 KSI .34 1.36 .019 .012 .20 .01 .14 YR-87-02-3ME-F FRC-29.0 141.0 KSI .36 .79 .019 .017 .29 .01 .12 YR-87-02-4tf6-F IRC-31.5 150.3 KSI 144.0 KSI .35 .74 .011 .013 .20 .02 .07 YR-87-02-SM6-F FNC-32.5 155.6 KSI 153.4 KSI .40 .98 <.002 .024 16 .04 .21 YR-87-02-&J6-F FEC-31.5 151.3 KSI 142.6 KSI .35 .76 .011 .046 .19 .02 .11 YR-87-02-7M6-F FOC-29.5 143.5 KSI 126.5 KSI .39 .81 .014 .015 .19 .18 .99 YR-87-02-EM6-F FRC-26.0 133.3 KSI 123.1 KSI .29 .77 .017 .016 .20 .02 .16 NR-07-02-9ff6-F

  • FHC-24.0 121.J KSI 92.3 KSI

.34 .79 .014 .012 .05 .01 .26 YR-87-02-10M6-F FRC-26.0 143.1 KSI 124.7 KSI .33 .83 .021 .015 .21 .02 .06 IVote: UTS-ultimate tensile strength; YS yield strength; C-carbon; Mn-Manganese; P-Phosphorus; S-Sulfur; Si-Silicon; Mo-Molybderun; Cr-Chromium. The elements listed apply to ASTM A193 B7 or SA193 B7 material. The elements to be reported for other materials tested, shall conform to those reported in the applicable material specification. Properties found out of specification shall be noted with an asterisk.

e Attachmat 2 Data Summary SSFETY RELATED MJTS Pbchanical Analysis Chemical l'nal vsis* ID # Hardness UTS O.27. YS C Mn P S Si Mo Cr YR-87-02-1SR-N FFE-29.0 .46 .74 .023 .021 .17 .01 .13 YR-8'7-02-2SR-N FFC-26.0 .48 .82 .019 .018 .28 .01 .08 YR-87-02-3SR-N FIC-32.0 .49 .72 .011 .017 .18 .01 .01 YR-87-02-45R-N FfE-26.0 .37 .73 .005 .029 .20 .01 .08 YR-87-02-bSR-N FfC-20.0 .46 .74 .022 .015 .24 .01 .07 YR-87-02-6SR-N FfC-28.0 .39 .80 .014 .015 .22 .01 .03 YR-87-02-7SR-N FfE-29.0 .43 .70 .014 .012 .22 .01 .01 YR-87-02-85R-N FEC-30.0 .37 .76 .012 .029 .20 .01 .08 YR-87-02-9ER-N FEC-36.0 .52 .71 .009 .017 .18 .01 .01 YR-87-02-10SR-N FEC-29.5 .46 .73 .023 .020 .18 .01 .13 YR-8'7-02-11SR-N FEC-29.5 .47 .74 .028 .021 .18 .01 .13 YR-87-02-12SR-N FfC-29.5 .46 .74 .029 .020 .16 .01 .14 YR-37-02-13SR-N FEC-26.0 .47 .82 .029 .017 .29 .01 YR-87-02-14SR-N Ff7C-29.0 .47 .73 .027 .021 .18 .01 .13

t Data StmTunary S9FETY RELATED PUTS Mechanica1 Analysis Chemica1 Ana1ysis1 ID # Hardness UTS O.27. YS C Mn P S Si Mo Cr YR-87-02-155R-N FfE-35.5 .47 .75 <.002 .033 .08 .01 .03 YR-87-02-16SR-N FfC-25.5

  • .31

.69 .006 .028 .18 .02 .06 YR-87-02-175R-N FIE-25.5 .40 .68 .017 .008 .20 .02 .24 YR-87-02-185R-N WC-28.5 .47 .74 .025 .020 .18 .01 .13 YR-87-02-195R-N WC-29.0 .42 .70 .025 .016 .21 .01 <.01 YR-87-02-20SR-N mC-29.5 .44 .74 .025 . J13 .22 .01 .01 Note: UTS-ultimate tensile strength; YS yield strength; C-carbon; M1-fianganese; P-Phosphorus; S-Sulfur; Si-Silicon; Mo-f1olybdenum; Cr-Chromium. The elements listed apply to ASTM A193 B7 or 54193 B7 material. The elements to be reported for other materials 2 tested, shall conform to those reported in the applicable material specification. Properties found out of specification shall be noted with an asterisk.

e, # 9 ATTACHMENT 3 Samp_le Identification No.: YR-87-02-9NNS-F

== Description:== 5/8" - 11 SAE J429 Grade 5 Bolt Discrepancy: SAE J429 requires a minimum Rockwell C hardness of 25 for grade 5 material. Ac tual Rockwell C hardness was determined to be 24. Evaluation: Sample No. YR-87-02-9NNS-F met all specification chemical and physical requirements with the exception of the Rockwell C hardness. The Rockwell C hardness test is a qualitative test. Actual material strength is determined by the tension test. Since this sample meets SAE J429 tensile requirements, the low Rockwell C hardness value does not limit application of this item. In addition it should be noted that this item is designated for non-nuclear safety applications and was purchased without specific physical and chemical requirements.

fi O Lyd 0 ~ ATTACHMENT 3 Sample Identification No.: YR-87-02-16SR-N

== Description:== 5/16" - 18 ASTM A194 Grade 2H Nut Discrepancy: ASTM specification A194 2H requires a minimum carbon content of .40%. Actual carbon content was determined to be 31%. Evaluati_o_n: Carbon content will generally affect two material properties, strength and ductility. Usually a lower carbon content will provide less strength but greater ductility. Therefore, sufficient ductility is not a concern for this sample. Strength of the material is approximated using the results of the Rockwell C hardness test. Since this item meets the hardness requirements it is expected that the strength requirement will be met also. In order to quantitatively determine the strength of this item, additional testing of nuts from the same heat number will be conducted which will include a proof load test in accordance with ASTM specification A370, S14. At that time the limiting application and safety significance of the low carbon content will be determined. The results of the proof load testing along with an evaluation of the sa fut y significance and application limits will be provided by March 13, 1988. Until the final evaluation is completed the material in question will be placed on hold. In addition, to determine the extent of nonconforming fasteners from this vendor, further sampling and testing is being conducted. The resuits of this testing will be provided by March 13. 1988. (i i l l i l J}}