TRANSPORTATION QUALITY ASSURANCE PROGRAM REVISION O

For APPROVED BY:

PREPARED BY:

CALUMET TESTING SERVICES, INC.

e+

CONTROLLED COPY NO. _

/

d, ~

_Ro ert J. \\Edimos, President Thomas J. Keirman l

TABLE OF CONTENTS SECTION TITLE 101.0 QUALITY ASSURANCE REQUIREMENTS 103.0 QUALITY ASSURANCE ORGANIZATION 105.0 QUALITY ASSURANCE PROGRAM 107.0 PACKAGE DESIGN CONTROL 109.0 PROCUREMENT DOCUMENT CONTROL 111.0 INSTRUCTIONS, PROCEDURES AND DRAWINGS 113.0 DOCUMENT CONTROL 115.0 CONTROL OF PURCHASED MATERIAL, EQUIPMENT AND SERVICES 117.0 IDENTIFICATION AND CONTROL OF MATERIALS, PARTS l

AND COMPONENTS 119.0 CONTROL OF SPECIAL PROCESSES I

121.0 INTERNAL INSPECTION 123.0 TEST CONTROL 1

l 125.0 CONTROL OF MEASURING AND TEST EQUIPMENT 127.0 HANDLING STORAGE AND SHIPPING CONTROL 129.0 INSPECTION TEST AND OPERATING STATUS 131.0 NONCONFORMING MATERIALS PARTS OR COMPONENTS 133.0 CORRECTIVE ACTION 135.0 QUALITY ASSURANCE RECORDS 137.0 AUDITS 0603190393 060210 PDR ADOCK 07100337 C

PDR

. CALUMET TESTING SERVICES, INC.

101.0

-QUALITY ASSURANCE REQUIREMENTS This program describes the quality assurance requirements for transport of sealed sources authorized by material license #13-16347-01 and owned by Columet Testing Services, Inc. (CTS). The sealed sources are used for Industrial rodlography.

103.0 QUALITY ASSURANCE ORGANIZATION The Radiation Safety Officer (RSO) is responsible to the President for implementing the Transportation Quality Assurance Program. The RSO has the responsibility to identify quality problems, provide solutions to quality problems, verify implementation of solutions and stop work when necessary.

The RSO is a rodlographer with at least one year experience. He has been trained in the requirements of this program. He is completely famillor with all the equipment used and functions corried out in the CTS radiography program. He has a thorough knowledge of management po!!cles and adminis-trative and operating procedures. He has a full understanding of rodlotion protection and control methods. His specific responsibilities are:

1.

Maintaining control of procurement and disposal of licensed material.

2.

Procuring and maintaining radiation survey Instruments.

3.

Establishing and maintaining storage facilities.

4.

Maintaining exposure devices, radiography facilities, and associated equipment.

5.

Performing source replacement and source tagging cpcrations.

6.

Conducting quarterly inventories and maintaining utilization logs.

7.

Implementing the Quality Assurance Program.

Responsibility for maintaining records as they pertain to the above functions con be designated to a responsible individual, but the ultimate responsibility for the records remains with the Radiation Safety Officer.

105.0

_UALITY ASSURANCE PROGRAM Q

105.1 This program applies to transportation of the following radioactive materials packages:

USA /6717/B(U)

For transportino Gammo Industries Model Century S exposure devices and Gamma Industries Model C-10 source changes (these devices may contain up to 100 curies Iridium-192)

USA /9036/B For tiansportIng Source Production & Equipment Company Model C-1 source changer (this device may contain up to 100 curies Iridium-192)

USA /9127/B For transporting up tc,100 curies Cobalt-60.

l This is a Gamma Industries Model Gammatron 100A exposure device.

4 5

CALUMET TESTING SERVICES, INC.

s i

105.2 Personnel who perform activities described in this program are l

trained to do so. Training is documented.

105.3 The status and adequacy of the Transportation Quality Assurance Program is reviewed on on annual basis by trained personnel who do not have responsibilities in the orcos being oudited.

107.0 PACKAGE DESIGN CONTROL i

Not applicable to CTS transport activities.

109.0 PROCUREMENT DOCUMENT CONTROL i

i 109.1 Procurement of sealed sources and transportation package components is covered by this program.

109.2 Procurement documents are prepared by the RSO and approved by l

acfninistrative personnel who are famillor with this program and the requirements for the ordered item (s).

i 109.3 Procurement documents contain the following information:

-A description of the item to be supplied l

-!dentificotton of the applicable shipping package (in the cose of l

j orders for sealed sources). Only USNRC approved packages are

{

specified.

i l

-Identification of documentation to be submitted to CTS.

i 109.4 Items covered by this program are obtained only from suppliers who have o quality assurance program opproved by the USNRC.

109.5 Changes to procurement documents are processed in the some manner as the original document.

i j

113.0 DOCUMENT CONTROL i

l 113.1 Documents which prescribe activities offecting quality are issued on a controlled basis and recorded in the document control log.

I 113.2 Documents which prescribe activities offecting quality are j

reviewed and opproved by the RSO.

l 113.3 Document changes are processed in the some manner as original documents.

113.4 Obsolete documents are recolled and destroyed.

115.0 CONTROL OF PURCHASED MATERIAL, EQUIPMENT AND SERVICES l

l Not applicable to CTS transport activities.

I i

t,.

?

I

y

=

CALUMET TESTING SERVICES, INC.

117.0 IDENTIFICATION AND CONTROL OF MATERIALS, PARTS AND COMPONENTS Not opplicable to CTS transport activities 119.0 CONTROL OF SPECIAL PROCESSES Not opplicable to CTS transport activities 121.0 INTERNAL INSPECTION 121.1 Transport packages are inspected before sources are transported and when sources are received. Inspection is performed in accordance with a written checklist. The checklist includes:

-Characteristics to be inspected

-Classification of personnel who are assigned to perform inspection

-Acceptance criteria

-Space for documenting results.

-instructions for handling nonconforming items.

121.2 Personnel performing inspections are trained to do so. Training is documented.

123.0 TEST CONTROL Not applicable to CTS transport activities.

125.0 CONTROL OF MEASURING AND TEST EQUIPMENT Not applicable to CTS transport activities.

127.0 HANDLING STORAGF. AND SHIPPING CONTROL Handling, storing and shipping is performed in accordance with written procedures. Cleaning and preservation are not applicable to CTS transport activities.

129.0 INSPECTION TEST AND OPERATING STATUS 129.1 The status of transport packages which do not comply with acceptance criterio is indicated by offixing on " INOPERATIVE" tog to the package.

A nonconformance report is completed and submitted to the RSO.

The status of transport packages which are not to0ged is " OPERATIVE".

131.0 NONCORFORMING MATEPfALS PARTS OR COMPONENTS Defective transport packages are removed from service and tagged. A Nonconformance Report is initiated and submitted to the RSO. The RSO determines and documents disposition.

CALUMET TESTING SERVICES, INC.

133.0 CORRECTIVE ACTION 4

133.1 Defective packages type USA /6717/B(U) and USA /9036/8 ore either j

scrapped or returned to the vendor for disposition 133.2 Defective packages type USA /9127/B(U) are also exposure devices.

Disposition of defective transport packages of this type is determined by the RSO in accordance with procedures determined by the 4

manufacturer.

133.3 In any case, corrective action is documented on the Nonconformance Report j

135.0 QUALITY ASSURANCE RECORDS '

,c m.,

135.1 The RSO molntains the folidwinTquiility" assurance records

- Reds of E '

~ ~ ~ ' ' ' ' ' ' ~ ' ' ' ' ~ ^

i

- Records of reviews -

- Records of audits

- Records of auditor qualification

~

i 135.2 Records are identifloble and retrievable 135.3 Records are retained indefinitely l

137.0 AUDITS i

137.1 The Transportation Quality Assurance Program'Is audited annually in occordance with written checklists 137.2 Audits are conducted by trained personnel who do riot have direct 4

responsibilities in the arcos being oudited i

137.3 Audit results are documented'on'd reviewed by the President i

137.4 Follow-up oction is taken where indicated I

J

}

I I

i l

I l

[

l 1

V o

?/-' d b7 DOCKET NO.

,$d k CONTROL NO.__ 8 8 ((

DATE Of D00.

DATE RCVD.

O

/,((

FCUF PDR FCAF LPLR t/M I6E REF.

I.MUF SAFEGUARDS

'~ C CC_[

OTliER

_ p 1Pf!ON:

,1, d

dv; 4A4 42omumm L

..Z C7 tw f

i

-