Forwards SER Re Generic Ltr 83-28 Concerning post-maint Testing Programs.Responses Acceptable
ML20142A126
Person / Time
Site: Yankee Rowe
Issue date: 03/13/1986
From: Clifford J
Office of Nuclear Reactor Regulation
To: Papanic G
YANKEE ATOMIC ELECTRIC CO.
Shared Package
ML20142A127 List:
References
GL-83-28, NUDOCS 8603190338
Download: ML20142A126 (3)


Text

. _ _ _

)

MAR 131986 Docket No.50-029 i

4 Mr. George Papanic, Jr.

Senior Project Engineer-Licensing Yankee Atomic Electric Company 1671 Worcester Road Framingham, Massachusetts 01701

Dear Mr. Papanic:

SUBJECT:

SAFETY EVALUATION REPORT FOR REVIEW 0F POST MAINTENANCE TESTING Re:

Yankee Nuclear Power Station Enclosed is the Safety Evaluation Report for our review of your Post-Maintenance Testing Programs. Our review covered the issues identified in Generic l.etter 83-28, items 3.1.3 and 3.2.3.

Based on our review, we find your responses to these issues acceptable.

James W. Clifford, Project Manager Project Directorate #1 Division of PWR Licensing-A

Enclosure:

Post Maintenance Testing SER j

cc w/ enclosure:

See next page i

i i

1 1

Office:

PM/

PD/ PAD #

Surname: JClifford/tg Glear Date:

03/l\\/86 03/, /86 8603190338 860313 PDR ADOCK 05000029 P

PDR

Mr. George Papanic, Jr.

Yankee Atomic Electric Company Yankee Nuclear Power Station cc:

Mr. James E. Tribble, President Yankee Atomic Electric Company 1671 Worcester Road Framingham, Masshchusetts 01701 Thomas Dignan, Esquire Ropes and Gray 225 Franklin Street Boston, Massachusetts 02110 Mr. N. N. St. Laurent Plant Superintendent Yankee Atomic Electric Company Star Route Rowe, Massachusetts 013S7

~

Chairman Board of Selectmen Town of Rowe Rowe, Massachusetts 01367 Resident Inspector Yankee Nuclear Power Station c/o U.S. NRC Post Office Box 28 Monroe Bridge, Massachusetts 01350 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 Robert M. Hallisey, Director Radiation Control Program Massachusetts Department of Public Health 150 Tremont Street, 7th Floor Boston, Massachusetts 02111

- -, - __.. -. -. -.-. -. - _-