Mr. H.R. Denton Attachnent to INLNRC 86-033 Page 1 of 2 CONTAItMENT SYSTEMS SURVEILLANCE REQUIREMENTS (Continued)

TABLE 4.6.1.2-1 The specified 24 month maximun surveillance interval may be extended during Cycle 1 until July 13, 1986 for the valves listed below. '1he provisions set forth in 10 CFR 50, Appendix J,

Paragraph III.D.3 are reset upon satisfactory perfonnance of the individual penetration surveillance.

Penetration Valve P-80 BG-8381 P-23 BG-HV8160 BG-HV8152 P-73 EF-HV45 EF-HV47 EF-HV49 I-22 BB-Vl48 BB-HV8351B P-40 BB-V208 BB-HV8351D P-39 BB-V178 BB-HV8351C i

P-41 BB-HV8351A P-71 EF-HV31 EF-HV33 l

i B603040470 86 82 PDR ADOCK O PDR i

P 1

L

~

Page 2 of 2 A.

CONTAINMENT SYSTEMS SURVEILLANCE REQUIREMENTS (Continued)

=

b.

If any periodic Type A test fails to meet either 0.75 L, or 0.75 L,

g the test schedule for subsequent Type A tests shall be reviewed and approved by the Commission.

If two consecutive Type A tests fail to meet either 0.75 L, or 0.75 L, a Type A test shall be performed at t

least every 18 months until two consecutive Type A tests meet either at which time the above test schedule may be resumed; 0.75 L, or 0.75 Lg TheaccuracyofeachTypeAtestshallbeverifiedbyasupplemental c.

test which:

f 1)

Confirms the accuracy of the test by verifying that the supple-mental test result, L, minus the sum of the Type A and the super-c imposed leak, L, is equal to or less than 0.25 L, or 0.25 L ;

g t

2)

Has a duration sufficient to establish accurately the change in leakage rate between the Type A test and the supplemental test; and 3)

Requires that the rate at whicn gas is injected into the contain-(

ment or bled from the containment during the supplemental test is between 0.75 L, and 1.25 L r 0.75 L and 1.25 L

  • a t

t

  • d.

Type B and C tests shall be conducted with gas at a pressure not less than P. 48 Psig, at intervals no greater than 24 months except for a

tests involving:

i 1)

Air lacks, 2)

Purge' supply and exhaust isolation valves with resilient material seals, and 3)

Valves pressurized with fluid from a seal system.

e.

Air locks shall be tested and demonstrated OPERABLE by the requirements of Specification 4.6.1.3; l~

f.

Purge supply and exhaust isolation valves with resilient material seals shall be tested and demonstrated OPERABLE by the requirements of Specification 4.6.1.7.2 and 4.6.1.7.4, as-applicable; i g.

Leakage from isolation valves that are sealed with fluid from a seal system may be excluded, subject to the provisions of Appendix J, i

Section III.C.3, when determining the combined leakage rate provided the seal system and valves are pressurized to at least 1.10 P

[

(53 psig), and the seal system capacity is adequate to maintain

~

system pressure for at least 30 days; and h.

The provisions of Specification 4.0.2 are not applicable.

WOLF CREEK - UNIT 1 3/4 6-3

  • h e specified 24 month surveillance interval may be extended during Cycle 1 until J

July 13, 1986 for the valves listed in Table 4.6.1.2-1.

% e provisions set forth in 10 CFR 50, Appendix J, Section III.D.3 are reset upon satisfactory performance of the individual surveillance.

l