ML20141M820

From kanterella
Jump to navigation Jump to search
Forwards Rev 0 to Audit Plan,Comanche Peak Steam Electric Station,Cable Tray & Conduit Support Reanalysis,Project 6410. Audit Meeting W/Ebasco Svcs,Inc Scheduled for End of Current Wk
ML20141M820
Person / Time
Site: Comanche Peak  
Issue date: 02/11/1986
From: Landers D
TELEDYNE ENGINEERING SERVICES
To: Noonan V
NRC - COMANCHE PEAK PROJECT (TECHNICAL REVIEW TEAM)
Shared Package
ML20141M821 List:
References
6410-46, NUDOCS 8602280308
Download: ML20141M820 (1)


Text

/VO Mta n

'#'TELEDYNE ENGNEERING SERVICES 130 SE COND Aw(P.Uf W A(TM AV V A$$ACHUSEI73 022$4 e6t h 893 3350 TA n i t t os324 75:8 February 11, 1986 6410-46 Mr. Vince Noonan, Project Director Comanche Peak Project U. S. Nuclear Regulatory Comission Office of Nuclear Reactor Regulation Division of Licensing Mail Stop P-234 Washington, D. C.

20555 Audit Plan - Cable Tray and Conduit Support Reanalysis

Subject:

Dear Mr. Noonan:

Attached is the subject TES audit plan. At your request, we are currently An audit meeting implementing this plan and have audited Impell and ANCO.

with EBASCO is scheduled for the end of this week.

If you have any questions please do not hesitate to contact me.

Very truly yours, TELEDYNE ENGINEERING SERVICES h 5 Ah%

Donald F. Landers Executive Vice President DFL/lh Attachment C. Tramell (USNRC) cc:

L.Shao(USNRC)

D. Jeng (USNRC)

C. Posiusny (USRNC)

R. D. Ciatto (TES)

E. A. Solla (TES)

J. Q. Cragin (TES) 6410 File (TES)

$IA**SNK 8

h D

o