Text
_
"MM MM*mWWe'N'3N MJif3r**uiswsi m m -
i 4 84 U.S. NUCLEAR HEGULATORY COMMISSl!N PAGE OF PACES l
MATERIALS LICENSE Amendment No. 04 Pursuant to the At'omic Energy Act of 1954,'as amended, the Energy Reorganization Act of 1974 (Public Law 93 -438), and Title 10, N
Code of Federal Regulations, Chapter I, Parts 30,31,32,33,34,35,40 and 70, and in reliance on statements and representations
[
heretofore r' ade by the licensee, a license is hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct, n
p l
source, and special nuclear material designated below; to use such material for the purpose (s) and at the place (s) designated below; to h
p deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). This g
license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is E
E subject to all applicable rules, regulations and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any conditions specified below.
I8 If p
E Licensee N
In accordance with letter dated E
- 3. Agunse number 1985, f
ril 26 1.
St. Francis College SNM-1003 is amended in its f
entirety to read as follows:
p.
E Loretto, Pennsylvania 15940
~ '
2~
F r.
- 4. Ex. iration date l
9 p
December 31, 1986 g
- 5. Docket <.
p Referem s No.
070-01050 y
- 6. Byproduct, source, and/or 4
7, Chemical and/or physical
.,8. Maximum amount that licensee F:
')may possess at any one time
/)
under this license N
s y
y A. Plutonium 239 A'.~ Encapsulated as a Pu-Be '
A. 32, grams
- eutron source
- 4^
B. Plutonium 239 8.~ elated Alpha source ;
B. 0.005 microcuries 7
j.
i
-s 9.
Authorized use L
.. ~.
...,ypi:
i..,~
v n,
i;'i s
p j
A.
For storage only.
7,f
- 2 j
B.
For storage only.
j L_
,y r
/.
i ;
._ CONDITIONS,
.,g k
c,
,, s
- 10. Licensed material shall be' stored only at the Physics Department, Sullivan Hall, St.
R Francis College, Loretto, Pennsylvania.
)
i
-(
r p
i
- 11. The licensee shall comply with the provisions of Title 10, Chapter 1, Code of Federal
$p i
Regulations, Part 19, " Notices, Instructions, and Reports to Workers; Inspections" and Part 20, " Standards for Protection Against Radiation."
k E
- 12. Licensed material shall be stored by, or under the supervision of, Peter Skoner.
L i
13.
A.
(1) Each sealed source containing licensed material, other than 11ydrogen 3, pl with a half-life greater than thirty days and in any form other than gas p
p(
shall be tested for leakage and/or contamination at intervals not to exceed h
six months, except that each source designed fcr the purpose of emitting l
alpha particles shall be tested at intervals not to exceed three months, In the absence of a certificate from a transferor, indicating that a test q
has been made within six months prior to the transfer, a sealed source pj received from another person shall not be put into use until tested.
p; F1 (2) Notwithstanding the periodic leak test required by this condition, any hl licensed sealed source is exempt from such leak tests when the source b
[::
contains 100 microcuries or less of beta and/or gamma emitting material or 10 microcuries or less of alpha emitting material.
p 8602280061 860102
(. h REG 1 LIC70 I
I g
SNM-1001,,
,,,,,,my,,,,,,, mygg mm m,,,,,,,,,,,,,.n, m
p------------
= = = = =--- --: m m - - = m_&_wm_ ?A%TamMMg_W_*4mg-- i slip q l
N.C Fesm 374A U.S. N TAR REGULATORY COMMISSION g
7 p
l Ucenw number l
l l
MATERIALS LICENSE SNM-1003 l
' SUPPLEMENTARY SHEET
)
i 070-01050
- p i
1 Amendment _No._0.4 N
g (13. continued)
CONDITIONS I
k, I
(3) Except for alpha sources, the periodic leak test required by this condition g
i does not apply to sealed sources that are stored and not being used. The k
N sources excepted from this test shall be tested for leakage prior to any R
l use or transfer to another person unless they have been leak tested within f
g six months prior to the date of use or transfer.
p 4
k i
B.
The test shall be capable of detecting the presence of 0.005 microcurie of g
i radioactive material on the test sample.
The test sample shall be taken from k
N the sealed source or from the surfaces lof the device in which the sealed source l
is permanently mounted or ' stored on which one might expect contamination to E
~
accumulate.
Records of leak test results sisall be kept in units of microcuries f
y g
and maintained for.inspe,ction by the Comission.
i p
E i
C.
If the test reveals'the presence of 0.005 microcurie or more of removable F
M contamination, the licensee shall immediately withdraw the sealed source from F
4 use and shall cause it.to#be decontaminated and repaired or to be disposed of in E
l accordance with Comissio'n'rigulations. A report shall be filed within 5 days f
Avenue, King of Prussia,iP{ennsylvania (19406, describing tha of the test with the U. LS. Nuclear Rdgulatory Con...ission, Region I, 631 Park g.
g quipment involved, p
g:
N the test results, and thefc_orrective. action taken, lk N
F
~
D.
Tests for leakage and/or co~ntamination shall be performed by the licensee or by E
l other persons specifically authorized by the Comission or an Agreement State to f
perform such services-g P
l 14. Sealed sources containing licensed matfrial shall not be opened.
F k
- 15. Except for plutonium contained in a medical device designed for individual human application, no plutonium, regardless of form, shall be delivered to a carrier for E
hl shipment by air transport or transported in an aircraf t by the licensee except in packages the design of which the NRC has specifically approved for transport of p
l plutonium by air.
b]
j I 16. Except as specifically provided otherwise by this license, the licensee shall possess I
and use licensed material described in Items 6, 7, and 8 of this license in accordance with statements, representations, and procedures contained in letters dated March 11, d'
1980, May 13, 1981, and April 26, 1985.
The Nuclear Regulatory Commission's W
regulations shall govern the licensee's statements in applications or letters, unless N
the statements are more restrictive than the regulations.