MCEl-(M00-05 2 of 273 Rev,01 McGuire Nuclear Station COLR-l i
l McGuire Unit-1 Cycle 8 I
-I l
Core Operating Limits Report July 1992-Revision 1 I
Duke Power Company j
Prepared by:
1,'/ / fld
_ k Man Checked by:
s:
_3 Approved by:,AbMM
- ggeq86afunjjgt P
- -
MCE14M00-05 3 of 273 Rev,01 McGuire 1 C cle N Core Operating 1.imits Report 3
REVISION I.OG F_. vision Effective Date Et'fective Pages Originalissue 19 November 1991 Pages 4 - 267,269, (Rev.0) 271 and 273 Revision 1 22 July 1992 Pages 1 - 3A,268, 270 and 272 J
$_m
_._m_
.m
MCF.1-04(X)-05 3A of 273 Rev.01 McGuire i Cycle 8 Core Operating 1.imits Report i
Insertion Sheet for Revision 1 Remove Rev. 0 Pages insert Rev. I Pages Pages1 3-Pages 1 - 3A Page 268 Page 268 Page 270 Page 270 Page 272 Page 272 f
3
-._g
MCEl-04(XI-0$
268 of 273 Rev,01 TABLE 6 CORE 0PL14700 LIMIT 3 PE W hT~
M DELTA-li VALUF.S {F-DELTA-H RAltGINI MH (2-01 AT: 100% 00Wh*.R 4 EFPD H
O F
E D
C B
A eseeeeese,eeeeeeeeeee s eeeeeeeeeeeeeeeeeeeeeeeeeeee***eveeeeeeeev 9
1.6155 -1.-004s L2c04 -1.0151 1.1236 1.04e5.-1,2315 1.2 M 1 9*
1.0900 1.2549. 1.0219 1.2314 1.0197 : 1.2265 1.0620 -1.5229' 10 ' - 1.2155 1.0217 1.1325 1.1244 1.1993 1.0402 1.1970 1.2793 11
- 1.. C2 57 1.2319 1.1234 1.1916 1.0454' 2.1590 -1.1215 1.7649 12
- 1.1284 1.0215 1.2004 1.0458 1.3540 1;1255 1.4465 13
- 1.0497 1.2261 1.0479 141585 1.1236 -1.4906 2.1059 14
- 1.2237 1.0617 1.1672 1.1215 1.4499 2.1052 15 *
-1.2263 1.5226 1.2793 1.7643 MH (2-D)
ATA 75% POWL71 4 EFFD-H G
F E
D.
C
'B A
e e e e e e e e e e e e e e e e................ e e e e e e e e e e e e e e e e e e e s e,
.. *,e e e e e 8 ',
2.0115
- 1. D11 1.4712 1,2010 1.3242 1.1683 1.1931 1.4091 9*
1.3373 1.5744 1.2423 1.4055 1.1870. 1.4082: 1.2214 1.7353 10
- 1.4819 1.2420 1.3635 1.3443-.l.4049 1.2227 1.3597 1.4336 11
- 1.2077 1.4862 1 3432 1.4H1 -1.2377 1.3934 1.2970 2.0479 12 '
1.3299 1.1891 1.4062
- 1. 2 %2 1.5624-1.3355 1.7074 lb '
-141085 1.4078 1.2222 '1.392?--133332 1.742G 2.4885 a
14 * - 1.3842 1.2210 1.3599 1.2970 1.7095-2.4970.
15
- 1.4094-1.7349 1.4337 2,04?1
MCill4WXM6 270 of 27.1
. Rev. 01 i
TABLE 6 (cont.)
COPE 01'IMTitu 1.1MITS El.itkT M-Dt.LTA-H VALt'EG (F-DELTA-H MAlditJ)
MH 12-D)
AT: 100% POWLk 200 ETID H
0 F
E D
C a
A B
1.4380 1.0426 1.1679 1.02$9 1.1496 1.0920 1.2007 1.2432 9*
1.0451 1.2176 1.0 N 1.2434 1.0294 1.2057 1.0054 1.4009 10
- 1.1737 1.0367 1.1447 1.1560 1.1961 1.0530 1.16BB 1.2076 11
- 1.02L6 1.2437 1.1562-1.2000 1.04:11 1.1546 1.1297 1-7217 12 ',
1.1426 1.0202
- 1. ' ~e61 1.0401 1.21416 1.1030 1.4230 13
- 1.D922 1.2055 1.0530 1.1539 1.1024 1.3966 1.0712 14
- 1.244?
1.0e5$ 1.1691 1.1298 1.4247 1 6707 15+
1.2433 1.4900 1.2B77 1.7214 MH (2-D)
ATt 7$% POWER 200 LFID H
0 F
E D
C ll A
e.......
.................................ee.......e..............
B' 1.7963 1.2)D1 1.3748 1.2115 1.3118 1.2507 1.4324 a.4426 9*
1.2819 1.4741 1.2397 1.4b60 1.2043 1.1950 1.2602 1.7170 10 '
1.3615
- 1. 2 41 f.
1.3370- 1.3756 1.4019 1.2230 1.3650 1.4372 11 '
1.2111 1.4$63 1.1748 1.4374 1.2698 1.3001 1.3042. 1.9883 12 '
1.3216 14029 1.4026 1.2697 1.5704 1.3372 1.7227 13 *
.1.2509 1.3955 1d229 1.3799 1.3365 1.7010- 2.2960 14
- 1.4250 1.2602. 1.3653 1.3043 1.7237 2.205L lb '
1.4427 1.7176 1.4374 1.9079.
MCE!4800 05 i
272 of 273 L
Rev. 01
\\
r TAHLE 6 {evnt.)
COEE OltF.ATING LIMITS REPCAT M OLI.TA-H VALUE9 (F DELTA H MARGINI MH (2~01 ATr 100% POWER 34 0 EITD l
H 0
F E
D C
B A
B*
1.3906 1.0652 1.1627 1.0344 1.1410 1.0904 1.2327 1.2345 9*
1.0661 1.2243 1.0443 1.2443 1.0306 1.1035 1.0651- '1.4366 10 1.1677 1.0449 1.1503 1.2005 1.1973 1.'0000_ 1.1770 1.2527 11 '
1.0342 1.2444 1.2000 1.2060 1.0001 1.1579 1.1411 1.6762 12
- 1.1 N 8 1.0379 1.1978 1,0679 1.2636 1.1147 1.4027 13,*
1.0906 1.1934 1.0f00 1.1578 1.1147 1.3615 1.7612 14
- 1.2287 1.0852 1.1773 1.1413 1.4034 1.7607 15
- 1.2346 1.4366 1.2529 1.6759 MH (?-D)
AT: 7 5 % PD*.ER 340 EFPD H
G F
E D
C D
A l
'.3709 1.1474 1.30 %~
1.2551 1.4230, *.4277 1 ~
~
0 1.6456 1.244B ~
s*
1.2459 1.4339 1.2289 1.4531 1.1694
- 1. 363 1.2562 1.6720 i
10
- 1,3768 1.2297-1.3466 1.3805 1.3793 1,2036 1.3258 1.4123 11
- 1.1971 1.4532 1 3799 1.4021 1.2320 1.3292 1.2E02-1.8865 12 * - 1. ~i s ti 4 1, 3 96 1.3769 1.2318 1.4493 1.2770 1.6205 1.2553 1.3562 1.2036 1.3291 1.2770 1.567*,
2.0551 13
- 14 '
1.4184 1 d563-_1.3261 1.2804 1.6213 2.0547
+
1 -
15 *-
1.4278 1.6720 1.4125 1.0881 i,
-.;.__-a......__.._,-._.-.w