| 05000461/LER-1997-001, :on 970103,nuclear Fuel Supplier Failed to Analyze Turbine Pressure Regulator Downscale Failure Event in off-rated Condition Per 10CFR21.21.Caused by Error in Nuclear Fuel Supplier.Mcpr Will Be Implemented |
- on 970103,nuclear Fuel Supplier Failed to Analyze Turbine Pressure Regulator Downscale Failure Event in off-rated Condition Per 10CFR21.21.Caused by Error in Nuclear Fuel Supplier.Mcpr Will Be Implemented
| 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 21.21(c)(4) 10 CFR 21.21(c)(3) |
| 05000461/LER-1997-002-01, Forwards LER 97-002-01 Re Failure to Complete TS 3.8.2 LCO Required Action B.4 Due to Personnel Error.Commitment Made within Ltr,Listed | Forwards LER 97-002-01 Re Failure to Complete TS 3.8.2 LCO Required Action B.4 Due to Personnel Error.Commitment Made within Ltr,Listed | |
| 05000461/LER-1997-003, :on 970128,failed to Recongnize Impact of Disconnecting Div 1 IRM Cable While Div 2 IRM Cable Was Disconnected Resulted in 2 Out of 4 RPS Actuation Being Satisfied.Caused by Personnel Error.Counseled Personnel |
- on 970128,failed to Recongnize Impact of Disconnecting Div 1 IRM Cable While Div 2 IRM Cable Was Disconnected Resulted in 2 Out of 4 RPS Actuation Being Satisfied.Caused by Personnel Error.Counseled Personnel
| 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(viii) |
| 05000461/LER-1997-004, :on 970204,failed to Properly Implement TS SR 3.6.5.3.3 Due to Inadequate Procedure.Revised Surveillance Procedure to Verify Valves Closed |
- on 970204,failed to Properly Implement TS SR 3.6.5.3.3 Due to Inadequate Procedure.Revised Surveillance Procedure to Verify Valves Closed
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) 10 CFR 50.73(s)(2)(vii) |
| 05000461/LER-1997-005-01, Forwards LER 97-005-01 Re Eighteen Containment Penetrations Susceptible to Thermally Induced over-pressurization Due to Unknown Cause.Util Will Modify Seven Containment Penetrations to Eliminate over-pressure Concern | Forwards LER 97-005-01 Re Eighteen Containment Penetrations Susceptible to Thermally Induced over-pressurization Due to Unknown Cause.Util Will Modify Seven Containment Penetrations to Eliminate over-pressure Concern | |
| 05000461/LER-1997-006-01, Forwards LER 97-006-01 Re Lack of Coordination of 120 Volt non-safe Shutdown Circuit Breakers in Distribution Panels W/Safe Shutdown Circuit Breakers,Causes Plant to Be Outside Design Basis | Forwards LER 97-006-01 Re Lack of Coordination of 120 Volt non-safe Shutdown Circuit Breakers in Distribution Panels W/Safe Shutdown Circuit Breakers,Causes Plant to Be Outside Design Basis | |
| 05000461/LER-1997-006, :on 970219,lack of Coordination of 120 Volt non-safe Shutdown Circuit Breakers in Distribution Panels W/Shutdown Circuit Breakers Causes Plant to Be Outside Its Basis.Corrected Circuit Breaker Problems |
- on 970219,lack of Coordination of 120 Volt non-safe Shutdown Circuit Breakers in Distribution Panels W/Shutdown Circuit Breakers Causes Plant to Be Outside Its Basis.Corrected Circuit Breaker Problems
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) |
| 05000461/LER-1997-007, :on 970227,lack of Procedural Guidelines for Maintaining Seismic Qualification Resulted in Division 3 Switchgear Outside Design Basis.Revised CPS Procedures.W/ |
- on 970227,lack of Procedural Guidelines for Maintaining Seismic Qualification Resulted in Division 3 Switchgear Outside Design Basis.Revised CPS Procedures.W/
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) 10 CFR 50.73(e)(2)(iv) |
| 05000461/LER-1997-008, :on 920408,determined That DG Undervoltage Relays Inoperable Due to Inadequate Process to Review Operability Requirements of Plant Equipment as Defined in Ts.Amend Requested to Change TS |
- on 920408,determined That DG Undervoltage Relays Inoperable Due to Inadequate Process to Review Operability Requirements of Plant Equipment as Defined in Ts.Amend Requested to Change TS
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(c)(2)(v) |
| 05000461/LER-1997-009-01, Forwards LER 97-009-01 Re Identification of Surveillance Procedure Which Does Not Adequately Consider Accuracy of Installed Instrumentation in Meeting TS Requirements for Reactor Core Isolation Cooling Pump.Commitments,Liste | Forwards LER 97-009-01 Re Identification of Surveillance Procedure Which Does Not Adequately Consider Accuracy of Installed Instrumentation in Meeting TS Requirements for Reactor Core Isolation Cooling Pump.Commitments,Listed | |
| 05000461/LER-1997-011, :on 860929,failed to Verify Breaker Closed at seven-day Frequency Required by TS Due to Omission of Breaker from Surveillance Procedure.Caused by Inadequate Procedures.Revised Procedures |
- on 860929,failed to Verify Breaker Closed at seven-day Frequency Required by TS Due to Omission of Breaker from Surveillance Procedure.Caused by Inadequate Procedures.Revised Procedures
| 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1997-013, :on 970508,failure to Adequately Verify That No Trips Existed During Surveillance Test Resulted in Inadvertent Actuation of Sgts.Caused by Personnel Error. Procedure CPS 9532.61 Was Revised |
- on 970508,failure to Adequately Verify That No Trips Existed During Surveillance Test Resulted in Inadvertent Actuation of Sgts.Caused by Personnel Error. Procedure CPS 9532.61 Was Revised
| 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) |
| 05000461/LER-1997-014, :on 880426,MSIV Closure Time Testing Was Not Adequate,Due to Procedural Inadequacy.Revised DPS 9061.09 to Account for Full Valve Travel & Verified MSIV Operability Before Plant Start Up |
- on 880426,MSIV Closure Time Testing Was Not Adequate,Due to Procedural Inadequacy.Revised DPS 9061.09 to Account for Full Valve Travel & Verified MSIV Operability Before Plant Start Up
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1997-016, :on 970617,failure to Provide Emergency Lighting for Safe Shutdown Equipment as Required by Plant Design Basis Was Noted.Cause Could Not Be Determined.Review of Each Fire Area in SSA Conducted |
- on 970617,failure to Provide Emergency Lighting for Safe Shutdown Equipment as Required by Plant Design Basis Was Noted.Cause Could Not Be Determined.Review of Each Fire Area in SSA Conducted
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition |
| 05000461/LER-1997-017, :on 970613,failed to Properly Calibrate MSL Radiation Monitoring.Caused Because Design Document That Provided Setpoints to Be Used Prior to Startup Did Not Address Need to Recalibrate Monitors.Revised Procedure |
- on 970613,failed to Properly Calibrate MSL Radiation Monitoring.Caused Because Design Document That Provided Setpoints to Be Used Prior to Startup Did Not Address Need to Recalibrate Monitors.Revised Procedure
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability |
| 05000461/LER-1997-018, :on 970823,inadequate Preventive Maint Led to Possible Failure of Westinghouse Dhp Circuit Breakers to Open on Demand.Performed Corrective Maint Tasks on Dhp Circuit Breakers |
- on 970823,inadequate Preventive Maint Led to Possible Failure of Westinghouse Dhp Circuit Breakers to Open on Demand.Performed Corrective Maint Tasks on Dhp Circuit Breakers
| 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor 10 CFR 50.73(a)(2)(viii) |
| 05000461/LER-1997-019, :on 860929,switchgear Heat Removal Sys Fan Discharge Damper Control Circuit Routed Through MCR Was Not Per Design Basis Due to Design Error.Installed Temporary Mod to Disconnect Damper Indication to MCR |
- on 860929,switchgear Heat Removal Sys Fan Discharge Damper Control Circuit Routed Through MCR Was Not Per Design Basis Due to Design Error.Installed Temporary Mod to Disconnect Damper Indication to MCR
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition |
| 05000461/LER-1997-020, :on 970715,discovered Failure to Document Effect of Degraded Coatings in Containment on Eccs.Caused by Failure of Personnel to Perform Evaluation on Degraded Coatings.Performed Evaluation & Removed Degraded Coatings |
- on 970715,discovered Failure to Document Effect of Degraded Coatings in Containment on Eccs.Caused by Failure of Personnel to Perform Evaluation on Degraded Coatings.Performed Evaluation & Removed Degraded Coatings
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability |
| 05000461/LER-1997-021, Forwards LER 97-021-00 & 10CFR21 Rept 21-97-040,re Control Circuit for Division 1 EDG Feed Breaker Which Did Not Meet Basis Due to Design Error | Forwards LER 97-021-00 & 10CFR21 Rept 21-97-040,re Control Circuit for Division 1 EDG Feed Breaker Which Did Not Meet Basis Due to Design Error | |
| 05000461/LER-1997-022-01, Forwards LER 97-022-01 & 10CFR21 Rept 21-97-036 Re Design of DG Ventilation Subsystems Outside Design Basis as Result of Failure to Include Min & Max Outside Air Temps Extremes,Due to Design Error.Ler Contains Listed Commitm | Forwards LER 97-022-01 & 10CFR21 Rept 21-97-036 Re Design of DG Ventilation Subsystems Outside Design Basis as Result of Failure to Include Min & Max Outside Air Temps Extremes,Due to Design Error.Ler Contains Listed Commitments | |
| 05000461/LER-1997-023-01, Inadequate Work Instructions Leads to Potential Over-Greasing of Motor Bearings Causing Potential Failure of Various Motors Has Been Canceled | Inadequate Work Instructions Leads to Potential Over-Greasing of Motor Bearings Causing Potential Failure of Various Motors Has Been Canceled | 10 CFR 50.73(a)(2)(v), Loss of Safety Function |
| 05000461/LER-1997-023, :on 971107,potential Overgreasing of Motor Bearings Causing Potential Failure of Various Motors,Was Determined.Caused by Inadequate Work Instructions.Briefed Electrical & Maint Supervisors on Issue |
- on 971107,potential Overgreasing of Motor Bearings Causing Potential Failure of Various Motors,Was Determined.Caused by Inadequate Work Instructions.Briefed Electrical & Maint Supervisors on Issue
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(e)(2) |
| 05000461/LER-1997-024, :on 970830,failure to Comply W/Ts Action Statement to Immediately Restore AC Power Sources Was Determined.Caused by Inadequate Interpretation of TS Action. Licensing Providing Staff Guidance |
- on 970830,failure to Comply W/Ts Action Statement to Immediately Restore AC Power Sources Was Determined.Caused by Inadequate Interpretation of TS Action. Licensing Providing Staff Guidance
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2) |
| 05000461/LER-1997-025, :on 971002,design Deficiency Resulted in Plant Being Outside Design Basis for Fire in Main CR Potentially Damaging Valves Required in Safe Shutdown of Plant.Cause Could Not Be Determined.Will Analyze MOV Control Circuits |
- on 971002,design Deficiency Resulted in Plant Being Outside Design Basis for Fire in Main CR Potentially Damaging Valves Required in Safe Shutdown of Plant.Cause Could Not Be Determined.Will Analyze MOV Control Circuits
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition |
| 05000461/LER-1997-026-01, Forwards LER 97-026-01,re Inadequate Procedure for Insp of Shutdown Swps for Excess Silt Which Resulted in Shutdown Swp Inoperability.Commitments Made in Rept,Listed | Forwards LER 97-026-01,re Inadequate Procedure for Insp of Shutdown Swps for Excess Silt Which Resulted in Shutdown Swp Inoperability.Commitments Made in Rept,Listed | |
| 05000461/LER-1997-027, :on 900831,installation of Mod of RHR Sys Was Outside Plant Design Basis.Caused by Misinterpretation of 10CFR50.59.Reviewed Current Safety Evaluation Program & Mod to RHR Sys Will Be Installed |
- on 900831,installation of Mod of RHR Sys Was Outside Plant Design Basis.Caused by Misinterpretation of 10CFR50.59.Reviewed Current Safety Evaluation Program & Mod to RHR Sys Will Be Installed
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition |
| 05000461/LER-1997-028, :on 971126,identified Inoperability of All in-service 33 480-volt K-line safety-related Circuit Breakers.Caused by Failure of ABB to Supply Properly Qualified Components Per 10CFR21.Will Replace Components |
- on 971126,identified Inoperability of All in-service 33 480-volt K-line safety-related Circuit Breakers.Caused by Failure of ABB to Supply Properly Qualified Components Per 10CFR21.Will Replace Components
| 10 CFR 21.21(c)(4) 10 CFR 21.21(c)(3) |
| 05000461/LER-1997-029, :on 971113,failure to Follow Plant Procedure When Erecting Scaffold Resulted in SR Area Cooler Becoming Inoperable Due to Seismic Qualification Concerns.Caused by Failure to Follow Plant Procedure.Modified Scaffold |
- on 971113,failure to Follow Plant Procedure When Erecting Scaffold Resulted in SR Area Cooler Becoming Inoperable Due to Seismic Qualification Concerns.Caused by Failure to Follow Plant Procedure.Modified Scaffold
| 10 CFR 50.73(c)(2)(ii)(B) |
| 05000461/LER-1997-030-01, Forwards LER 97-030-01,re Failure to Verify That RWCU Sys Was Available as Alternate Means of Shutdown Cooling Due to Procedural Inadequacy.Commitments Made within Ltr,Listed | Forwards LER 97-030-01,re Failure to Verify That RWCU Sys Was Available as Alternate Means of Shutdown Cooling Due to Procedural Inadequacy.Commitments Made within Ltr,Listed | |
| 05000461/LER-1997-031, :on 971113,inadequate Testing of SR Logic Circuits Resulted in Failure to Meet TS Sr.Cause Has Not Been Determined.No Actions Have Been Taken at Present Time |
- on 971113,inadequate Testing of SR Logic Circuits Resulted in Failure to Meet TS Sr.Cause Has Not Been Determined.No Actions Have Been Taken at Present Time
| |
| 05000461/LER-1997-033, :on 971218,shift Supervisor Recognized That Containment Bldg Fuel Transfer Pool Ventilation Plenum Exhaust Radiation Monitors Declared Inoperable.Caused by Misinterpretation of Tech Specs.Operations on TS Revised |
- on 971218,shift Supervisor Recognized That Containment Bldg Fuel Transfer Pool Ventilation Plenum Exhaust Radiation Monitors Declared Inoperable.Caused by Misinterpretation of Tech Specs.Operations on TS Revised
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1997-034-01, Forwards LER 97-034-01 & Part 21 Rept 21-97-051 Re Incorrect Cable Resistance & Brake Horsepower Data Used in Design of Divisions 1 & 2 EDG Vent Fans Which Resulted in Design of Fan Monitors Being Outside Design Basis of Pla | Forwards LER 97-034-01 & Part 21 Rept 21-97-051 Re Incorrect Cable Resistance & Brake Horsepower Data Used in Design of Divisions 1 & 2 EDG Vent Fans Which Resulted in Design of Fan Monitors Being Outside Design Basis of Plant | |
| 05000461/LER-1997-034, Forwards 930414 S&L Electrical Engineering Std ESA-102 W/Copyright Statement Removed.Encl Originally Submitted w/980205 Info Re CPS Combined LER 97-034-00 & Part 21 Rept Contained Copyright Statement | Forwards 930414 S&L Electrical Engineering Std ESA-102 W/Copyright Statement Removed.Encl Originally Submitted w/980205 Info Re CPS Combined LER 97-034-00 & Part 21 Rept Contained Copyright Statement | |
| 05000461/LER-1997-035-01, Forwards LER 97-035-01,re Divisions 1 & 2 Battery Chargers Incapable of Supplying Full Rated Voltage & Current Flow at Degraded Voltage Trip Setpoint IAW Plant TS & Design Basis.Commitments Made within Ltr,Listed | Forwards LER 97-035-01,re Divisions 1 & 2 Battery Chargers Incapable of Supplying Full Rated Voltage & Current Flow at Degraded Voltage Trip Setpoint IAW Plant TS & Design Basis.Commitments Made within Ltr,Listed | |
| 05000461/LER-1997-036, :on 971222,engineering Completed Evaluation of Missing Motor Shaft Key That Connects Motor to Fan Hub of Div II Shutdown SW Pump Room Cooler.Caused by Inoperability of Room Cooler.Cooling Fan Restored,Per 10CFR21 |
- on 971222,engineering Completed Evaluation of Missing Motor Shaft Key That Connects Motor to Fan Hub of Div II Shutdown SW Pump Room Cooler.Caused by Inoperability of Room Cooler.Cooling Fan Restored,Per 10CFR21
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 21.21(d)(4) 10 CFR 21.21(d)(3) |