Text

_

c Unit;d Stat:s Enrichmint Corporation 2 Democracy Center L-6903 Rockledge Drive Bethesda, MD 20817 Tel. (3011564-3200 Fax: (301) 564-3201 United Sales Emichment Corporation JAMES H. MILLER Dir: (301) 564-3300 VicE PRESIDENT, PRODUCTION Fax: (301) 571-8279 July 15,1997

)

Dr. Carl J. Paperiello SERIAL: GDP 97-0119 Director, Oflice of Nuclear Material.

Safety and Safeguards Attention: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Paducah Gaseous Diffusion Plant (PGDP)

Docket No. 70-7001 Transmittal of Revision 12 to Paducah Certification Application

Dear Dr. Paperiello:

In accordance with 10 CFR Part 76, the United States Enrichment Corporation (USEC) hereby submits twenty (20) copies of Revision 12 (July 24,1997) to USEC-01, Application for United States Nuclear Regulatory Commission Certification, Paducah Gaseous Diffusion Plant.

Revision 12 incorporates changes to the Technical Safety Requirements (TSR). These changes were previously' submitted for your review in accordance with 10 CFR 76.45 and were approved as Amendment 5 to the Certificate of Compliance GDP-1 in your letter dated June 24,1997 (TAC NO.

L32025). Revision 12 also incorporates changes to TSR basis statements. These additional changes have been reviewed in accordance with the requirements of 10 CFR 76.68 and have been determined not to require prior NrtC approval. Revision bars are provided in the right-hand margin to identify the changes.

Revision 12 ? 'l be implemented on July 24,1997.

\\

9707220228 970715 ji PDR ADOCK 07007001 C

PDR 020067 llllll!llllllllllilJllllill!lilllll Offices in Paducah. Kentucky Portsmouth. Ohio Washington, DC

Dr. Carl J. Paperiello July 15,1997 GDP 97-0119 Page 2 Should you have any questions or comments on Revision 12, please call me at (301) 564-3309 or Steve Routh at (301) 564-3251. The enclosure identifies commitments made in this submittal.

l Sincerely,

-DhML ames H. Miller Vice President, Production

Enclosure:

Commitments Contained in this Submittal

Attachment:

USEC-01, Application for United States Nuclear Regulatory Commission Certification, Paducah Gaseous Diffusion Plant, Revision 12, Copy Numbers 567 through 586 cc:

NRC Region III Office Copy Numbers 442,664 NRC Resident Inspector - PGDP Copy Number 697 NRC Resident Inspector - PORTS Copy Number 665 Mr. Joe W. Parks (DOE)

Copy Numbers 641 through 644

Enclosure to GDP 97-0119 Page1 ofI Commitments Contained in This Submittal

1. Revision 12 will be implemented on July 24,1997.

._ -.. -. _ _ _ _ _.. _ _.. _ _ _ _ _. _.. _ _. _ _ _ _ _ _ _ _ _ _ _ _. _ _ ~

{'

I i

OATH AND AFFIRMATION.

i i

I, James H. Miller, swear and aflirm that I am Vice President, Production, of the United States Enrichment Corporation (USEC), that I am authorized by USEC to sign and file with the Nuclear Regulatory Commission this Revision 12 of the USEC Application for United States Nuclear Regulatory Commission Certification, Paducah Gaseous Diffusion Plant (USEC-01), that I am familiar with the contents thereof, and that the statements made and matters set forth therein are true and correct to the best of my knowledge, information, and belief.

Ja H. Miller

/b ay of l-

,1997.

Subscribed to before me on this U

>bsxOi)lbh/edW Notary Public BETMCE R. LAW 50N NOTM.Y E.CLIC SIAIU G MM'MO CorClicato (Ld b Mr.t:frarfCant/

j Commission Enka t,ugust 1,1977 -

l

~

..... [APPLIC5TIDNFORUNITEDSTATESE.

~

NUCLEAR REGULATORY. COMMISSION CERTIFICATION '

?PADUCAH GASEOUS DIFFUSIONPLANT i

REMOVE /INSERTINSTRUCTIONSi:

e
n REVISION 12 W

? JULY 24,1997

{

j Remove Pages Insert Pages VOLUME 4 List of Effective Pages List of Effective Pages ii,iii ii,iii Section 2.1 Section 2.1 2.1-10,2.1 20 2.1-10,2.1-20 Section 2.2 Section 2.2 2.2-9 2.2-9 Section 2.3 Section 2.3 2.3-7, 2.3-23, 2.3-50 2.3-7,2.3-23,2.3-50 Section 2.4 Section 2.4 2.4 12 2.4 12

. TSR-PGDP July 24,1997 Rev.12 LIST OF EFFECTIVE PAGES Pages Revision P_agg Revision il 12 2.1-24 6

iii 12 2.1-25 5

iv 11 2.1-26 5

v 11 2.1-27 5

vi 5

2.1-28 5

vii 5

2.1-29 5

viii 5

2.1-30 5

ix 5

2.1-31 5

i x

5 2.1-32 5-1 xi 5

2.1-33 5

xii 5

2.1-34 5

1 2.1-35 5

1.0-1 5

2.1-36 5

1.0-2 11 2.1-37 5

1.0-3 11 2.1-38 5

1.0-4 11 2.1-39 5

1.0-5 11 2.1-40 5

1.0-6 11 2.1-41 5

1.0-7 11 2.1-42 5

1.0-8 11 2.1-43 5

1.0-9 11 2.1-44 5

2.1-45 5

1 2.0-1 5

2.1-46 5

2.1-47 5

2.1-1 5

2.1-48 5

2.1-2 5

2.1-49 5.

2.1-3 5

2.1-50 7

2.1-4 7

2.1-51 5

2.1-5 5

2.1-52 5

2.1-6 5

2.1-7 5

2.2-1 5

2.1-8 5

2.2-2 5

2.1-9 5

2.2 7 2.1-10 12 2.2-4 5

2.1-11 5

2.2-5 5

-2.1-12 5

2.2-6 5

2.1-13 5

2.2-7 5

2.1-14 5

.2.2-8 5

2.1-15 5

2.2-9 12 2.1-16 5

2.2-10 5

2.1-17 5

2.2-11 5

n 2.1-18 5

2.2-12 5

2.1-19 5

2.2-13 5

2.1-20 12 2.2-14 5

2.1-21 5

2.2-15 6

2.1-22 6

2.2-16 5

2.1-23 5

TSR.-PGDP July 24,1997 Rev.12 LIST OF EFFECTIVE PAGES (Continued)

Pages Revision Pages Revision 2.2-17 6

2.3-26 5

2.2-18 5

2.3-27 5

2.2-19 5

2.3-28 5

2.2-20 5

2.3-29 5

2.2-21 5

2.3-30 5

2.2-22 5

2.3-31 5

2.2-23 5

2.3-32 5

2.2-24 5

2.3-33 5

2.2-25 5

2.3-34 5

2.2-26 5

2.3-35 5

2.2-27 5

2.3-36 5

2.2-28 5-2.3-37 5

2.2-29 5

2.3-38 5

2.2-30 5

2.3-39 5

2.2-31 5

2.3-40 5

2.2-32 5

2.3-41 5

2.2-33 5

2.3-42 5

2.2-34 5

2.3-43 5

2.3-44 5

2.3-1 5

2.3-45 5

2.3-2 5

2.3-46 5

2.3-3 5

2.3-47 5

2.3-4 5

2.3-48 5

2.3-5 5

2.3-49 5

~2.3-6 5

2.3-50 12 2.3-7 12 2.3-51 5

2.3-8 5'

2.3-9 5

2.4-1 5

2.3-10 5

2.4-2 5

2.3-11 5

2.4-3 5

2.3-12 5

2.4-4 7

2.3-13 5

2.4-5 5

2.3-14 5

2.4-6 5

2.3-15 5

2.4-7 5

2.3-16 5

2.4-8 5

1 2.3-17 5

2.4-9 5

2.3-18 5

2.4-10 5

2.3-19 6

2.4-11 5

2.3-20 5

2.4-12 12 1

2.3-21 6

2.4-13 5

l 2.3 5 2.4-14 5

2.3-23 12 2.4-15 5

2.3-24 5

2.4-16 5

2.3-25 5

2.4-17 6

I m

iii

  • TSR-PGDP July 24,1997 Rev.12 SECTION 2.1 SPECIFIC TSRs FOR TOLL TRANSFER AND SAMPLING FACILITY (C-360) 2.1.3 LIMITING CONTROL st;111NGS, LIMITING CONDITIONS FOR OPERATION, SURVEILLANCES 2.1.3.2 AUTOCLAVE PRESSURE RELIEF SYSTEM (continued)

BASIS:

This system prevents catastrophic failure of the autoclave, and subsequent uncontrolled UF 6 release, by allowing small (relative to the release associated with autoclave rupture), controlled releases in the unlikely event of concurrent UF release and excessive autoclave water inventory.

6 The ASME Code regmres that overpressure relief be provided by a device stamped at or below the MAWP and sized such that the subsequent transient pressure will be limited to a maximum of 110% of MAWP when a single relief path is used. The ASME Code allows rupture discs to ~

have a 5% burst tolerance. Rupture discs stamped at MAWP will therefore burst at or below 105% of MAWP. Thus, the LCS is set at 105% of MAWP. To comply with these standards, pressure relief devices are purchased and installed with stamped ratings at or below the MAWP.

l

[SAR Section 4.3.5.1.1]

l 1

~

l 2.1-10 I

l

]

1

' TSR-PGDP July 24,1997.

Rev.12' SECTION.2.1 SPECIFIC TSRs FOR TOLL TRANSFER AND SAMPLING FACILITY (C-360) q j

2.1.4 GENERAL LIMITING CONDITIONS FOR OPERATION 1

2.1.4.4 CYLINDER SCALE CART MOVEMENT PREVENTION SYSTEM LCO 2.1.4.4: The cylinder scale cart movement prevention system shall be oper.able.

APPLICABILITY: Modes: 6B ACTIONS:

Condition Required Action Completion Time i

A.

Cylinder scale cart A.1 Verify that the 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> j

movement prevention system system's key is inoperable.

hanging from the receiving cylinder's pigtail.

AND A.2 Tag out the air 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> connector on the supply for the scale cart motor.

NOTE: Current operatmg cycle may be completed.

B.

Scale cart movement B.1.1 Tag out the air 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> prevention system key is connector on the air discovered not hanging from supply for the scale

- the receiving cylinder's cart motor.

I pigtail without entry into QB condition A.

B.1.2 Stop operations in 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> mode 6B AND Purge and evacuate the receiving cylinder's pigtail, disconnect the pigtail, and hang the system's key on the pigtail.

w 2.1-20

TS,R-PGDP July 24,1997 Rev.12 SECTION 2.2 SPECIFIC TSRs FOR UF FEED FACILITIES (C-333-A AND 6

C-337-A) 2.2.3 LIMITING CONTROL SETTINGS, LIMITING CONDITIONS FOR OPERATION, SURVEILLANCES 2.2.3.2 AUTOCLAVE PRESSURE RELIEF SYSTEM (continued)

BASIS:

This system prevents catastrophic failure of the autoclave, and subsequent uncontrolled UF6 release, by allowing small (relative to the release associated with autoclave rupture), controlled releases in the unlikely event of concurrent UF release and excessive autoclave water inventory.

6 The ASME Boiler and Pressure Vessel (B & PV) Code requires that overpressure relief be provided by a device stamped at or below the MAWP and sized such that the subsequent transient pressure will be limited to a maximum of 110% of MAWP when a single relief path is used. The '

ASME B & PV Code allows rupture discs to have a 5% burst tolerance. Rupture discs stamped at MAWP will therefore burst at or below 105% of MAWP. Thus, the LCS is set at 105% of MAWP. To comply with these standards, pressure relief devices are purchased and installed with stamped ratings at er 'oelow the MAWP. [SAR Section 4.3.1.1.1]

l m

2.2-9

TSR-PGDP July 24,1997 Rev.12 SECTION 2.3 SPECIFIC TSRs FOR PRODUCT AND TAILS WITHDRAWAL FACILITIES 4

2.3.3 LIMITING CONTROL SETTINGS, LIMITING CONDITIONS FOR OPERATION, SURVEILLANCES

{

J 2.3.3.2 R-114 COOLANT OVERPRESSURE CONTROL SYSTEM LCS 2.3.3.2: C-310: The R-114 coolant rupture discs shall actuate at or below 210 psig.

C-315: The R-114 coolant rupture discs shall actuate at or below 420 psig.

i I

LCO 2.3.3.2: The R-114 coolant overpressure relief system shall be operable.

APPLICABILITY: Modes: 2 ACTIONS:

Condition Required Action Completion Time a

A.

R-114 coolant overpressure A.1 Place the condenser in Ihour relief system inoperable.

mode 3.

B.

The R-114 coolant B.1 Open the valve or Immediately.

J overpressure relief system verify it is open.

l manualisolation valve A_ND found unsealed or closed.

B.2 Reseal the valve..

8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> C.

Action item B not C.1 Place the UF Immediately.

6 j

satisfactorily completed.

condenser in mode 3.

1 f

SURVEILLANCE REQUIREMENTS:

Surveillance Frequency

)

SR 2.3.3.2-1 Visually inspect the R-114 coolant condenser Quarterly overpressure control system manual isolation 4

valve to ensure it is sealed open.

BASIS:

l The AShE code requires that overpressure relief be provided by a device stamped at or below the MAWP and sized such that the subsequent transient pressure will be limited to a maximum of 110%

ofMAWP when a single relief path is used. AShE code allows rupture discs to have a

  • 5% burst tolerance. Rupture discs stamped at MAWP will therefore burst at or below 105% of MAWP. Thus, the LCS is set at 105% of MAWP. To comply with these standards, pressure relief devices are purchased and installed on the coolant condensers with stamped ratings at or below the MAWP.

l

[SAR Section 4.3.3.1.2 and 4.3.4.1.2]

2.3-7

I

' TSR-PGDP July 24,1997 Rev.12 SECTION 2.3 SPECIFIC TSRs FOR PRODUCT AND TAILS WITHDRAWAL FACILITIES 2.3.4 GENERAL LIMITING CONDITIONS FOR OPERATION 2.3.4.8 FIRE PROTECTION SYSTEM - BUILDING SPRINKLER SYSTEM j

l LCO 2.3.4.8:

The fire protection sprinkler systems in process buildings C-310 and C-315 (exclusions: the dry pipe sprinkler system in C-310 arid the deluge system for the i

exterior transformer located adjacent to C-315) shall be operable.

APPLICABILITY:

Modes: At all times except when the lube oil is valved off or removed from l

the equipment covered by a specific sprinkler system.

1 ACTIONS:

Condition Required Action Completion Time A.

A control valve (i.e.,

A.1 Restore to the open position.

2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> shutoff valve)in the feed main to the sprinkler system is not in the open position.

B.

Action item A not B.1 Conduct a fire patrol for the 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> and every hour satisfactonly affected area (s) of the affected thereafter.

accomplished.

building (s).

M B.2 Confirm at least one HPFW 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> l

hydrant adjacent to the affected building (s)is operable.

TSR 1.6.2.2(d) is not applicable.

C.

The sprinider system fails C.1 Restore to operable status.

2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> one or both functional tests.

(See Basis for description of functional tests.)

D.

Action Item C not D.1 If a fire alann fails to soundin 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> and even hour satisfactorily C-300 within 90 seconds after thereafter, accomplished.

opening the inspectors test valve (ITV), conduct a fire patrol for the affected area (s).

M D.2 Ifno water flows from the 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> ITV or main drain, confmn at least one HPFW hydrant adjacent to the affected building (s)is operable.

TSR 1.6.2.2(d) is not applicable.

2.3-23

j TSR.PGDP July 24,1997 Rev.- 12 SECTION,2.3 SPECIFIC TSRs FOR PRODUCT AND TAILS WITHDRAWAL j

FACILITIES

.2.3.5. GENERAL DESIGN FEATURES i

2.3.5.5 SCALE CART DESIGN i

4 DF 2.3.5.5: The scale carts are designed with a minimum capacity of 20 tons and have a " low boy" design.

l SURVEILLANCE REQUIREMENTS:

i Surveillance Frequency SR 2.3.5.5-1 Visual inspection of the scale cart for structural Biennially damage, degradation, cracks, distorted members and loose fasteners.

BASIS:

This design feature minunizes the possibility of the " liquid cylinder rupture" accident scenario.

[SAR Section 4.3.3.1.5 and 4.3.4.1.5]

2.3.5.6 UF, CONDENSER AND ACCUMULATOR MINIMUM WALL THICKNESS DF 2.3.5.6: The vithdrawal area UF condensers and accumulator vessels have the minimum required metal thicknesses in accordance with ASME requirements.

SURVEILLANCE REQUIREMENTS:

Surveillance Frequency SR 2.3.5.6-1 Visual inspection, including thickness Five Years measurements, shall be taken on the withdrawal area UF condensers and UF accumulators at least 6

every five years in order to verify the vessel wall has not been reduced below minimum required metal thicknesses.

. BASIS:'

Ensuring vessel integrity of the UF condensers and accumulators helps prevent a UF release.

6 6

The minimum thicknesses for the condensers and accumulators were established in accordance with the 1986 edition of the ASME Boiler and Pressure Vessel Code,Section VIII, Division 1.

Surveillance frequency and monitoring points are established and inspections conducted in accordance with the current revision of the National Board Inspection Code (NIBC). [SAR Section 4.3.3.1.2 and 4.3.4.1.2]

~

2.3-50

c

  • TSR-PGDP July 24,1997 Rev.12 SECTION.2.4 SPECIFIC TSRS FOR ENRICHMENT CASCADE FACILITIES 2.4.3 LIMITING CONTROL SETTINGS, LIMITING CONDITIONS FOR OPERATION, SURVEILLANCES 2.4.3.4 R-114 COOLANT OVERPRESSURE CONTROL SYSTEM (continued)

SURVEILLANCE REQUIREMENTS:

Surveillance Frequency SR 2.4.3.4-1 Visually inspect the R-114 cell coolant Quarterly overpressure control system manual isolation valve to ensure it is sealed open.

SR 2.4.3.4-2 Visually inspect the cavity vent port Quarterly between tandem-mounted rupture discs to ensure it is open to atmosphere.

~

BASIS:

The ASME code requires that overpressure relief be provided by a device stamped at or below the MAWP and sized such that the subsequent transient pressure will be limited to a maximum of 110% of MAWP when a single relief path is used. ASME Boiler and Pressure Vessel (B & PV) code allows rupture discs to have a i 5% burst tolerance. Rupture discs stamped at MAWP will therefore burst at or below 105% of MAWl. Thus, the LCS is set at 105% of MAWP. To comply with these standards, pressure relief devices are purchased and installed on the cascade cell coolant condensers with stamped ratings at or below the MAWP. [SAR Section 4.3.2.4.1]

l 2.4-12