DUKE POWER GOMPANY 1*.O. ISOX 33180 CIIAltIMITE, N.C. 28242 IIAL 11. TUCKElf TELEPIIONE (704) 373-4531 UU JM 3 P ll 24 jutv4 EAR P. ode'OT104 SElmTY WED December 18, 1985 Dr. J. Nelson Grace, Regional Administrator U. S. Nuclear Regulatory Commission Region II P. O. Box 2203 Atlanta, Georgia 30301
Subject:
Oconee Nuclear Station IE Inspection Report 50-269/85-05 50-270/85-05 50-287/85-05 Supplemental Response to the Duke Response of April 26, 1985
Dear Dr. Grace:
During the week of December 9, 1985, NRC/ Region II Inspector O. M.
Masnyk conducted a routine security inspection of Oconee Nuclear Station.
In the process of the inspection Ms. Masnyk reviewed the Duke response to violation 50-269, -270, -287/85-05-01 (jump test) and questioned the physical description of site perimeter intrusion detection units.
Based on conversation between your staff and my staff it was determined that some of the technical information approximated in our April 26, 1985 response was in error.
During the December 16-17, 1985 period of time this was corrected by a comprehensive review of the physical layout of the perimeter alarm system by station personnel to confirm barrier and detector configuration.
The corrected information is available at the station for your inspection.
Duke recognizes the need to resolve and close this violation as expeditiously as possible.
The options will be evaluated to determine the corrective steps we intend to take and you shall be informed of these corrective steps in a supplemental response to be provided within the first quarter /1986.
If there are any questions or problems concerning this matter, please advise.
Very truly yours, h / r -e Hal B.
Tucker JWD:slb 8601080225 851218 PDR ADOCK 05000269 G
- CET0/
..-dr. J.~-halcon Graca, Rigional Administrator December 18, 1985 Page.Two ec:
Mr. J. C. Bryant NRC Resident Inspector p