Nuclear Materials and Equipment Corporation REGULATORY FILE CY '
a subsidiary of Babcock &Wilcox 609 North Warren Avenue. Apollo, Pa.15613 Telephone:(412) 842-0111 June 2, 1972 9
e U.S. Atomic Energy Comission 7920 Norfolk Avenue (T \\/[
k 9
fil M., V L.
p Bethesda, Maryland 20014 UUN 6 '1972> ^
Attention: Mr. Donald A. Nussbaumer L
Assistant Director for Materials
"-lyg5lf" Division of Materials Licensing reaw 9
nu suun
Subject:
BB-250-2 Shipping Container Modifications G
Reference:
SNM-145, Docket 70-135 SNM-928, Docket 70-925 SNM-338, Docket 70-337 Gentlemen:
NUMEC hereby requests authorization to deliver special nuclear material to a carrier for transport in a modified Westinghouse Shipping Container Model B8-250-2.
The modification replaces the presently licensed insert with a rectangular column insert.
We have determined that this modification will not i
affect the integrity or the radiological safety of the container.
We have also evaluated this modification for nuclear safety and determined the modification to be safe from that standpoint. A copy of that evaluation is enclosed, along with copies of NUMEC Drawing 10F578 and 10C1097 which show the modification.
We need to use this container by July 1,1972, and so would appreciate as prompt a review as possible.
If you have any questions, please contact me.
I Very truly yours, W
g.
\\
Q h
tTfG 7-E.K. Reitler, Jr., Manager goj7.#
Health, Safety and Licensing 6-EKR/did
.q Enclosure ht 7
33D3 8601070788 720602 PDR ADOCK 07000135 C
C 3.. 7 o
o 88-250-2 SHIPPING CONTAINER MODIFICATIONS
=,2 h
Nuclear Safety of Individual Container Each BB-250-2 contains a maximum of 250 pounds of UO 3
2 in the fonn of sintered pellets, enriched to a maximum of 3.5% in the U-235 isotope. The maximum H/U atomic ratio, considering all sources of hydrogeneous material within the containment vessel shall not exceed 3.
The maximum fissile weight for each f,M.
. container is 3.5 kg of U-235 The containment vessel (6.5" x 9" x 63") is subcritical by geometry for the
~ maximum enrichment being transported (3.5% U-235) for optimum moderation and full reflection.
For these worst conditions, Battelle Northwest Laboratory used the GEM-III Monte Carlo physics code to calculate a keff = 0.93 in the demonstration of nuclear safety of the inner container of the KM-2 shipping container (7.25" x 9" x 73").
This demonstration is given in Attachment A to Reference 1.
Since the inner container for the 88-250-2 is smaller and of the same geometry (rectangular parellelpiped), the application of the BNWL calculations to this container is conservative.
Nuclear Safety of Array The ability of the BB-250-2 to exclude water from the inner container after being subjected to the hypothetical accident conditions has been demonstrated.
Thus, the array is evaluated considering interunit water moderation which nold t
the undennoderated UO2 pellets.
Reference 1 demonstrates the safety of 350 undamaged KM-2 containers in any arrangement, with optimum interunit water moderation, and fully reflectea.
140 damaged KM-2 containers under the same conditions were also demonstrated P
to be safe.
The BNWL calculations found that an 11 x 11 x 3 array of undamaged Q-t w c-
- e. w
-mmma-w-
,w.w a
, mm u.,m m __ m.
mm
-,,mm,mm,,.__m_,_m.m_m____.
s.m,
. f
-.,# m my,_e,
,%-g - vr
%e_w---
[
._[
w 9
o i
BB-250-2 SHIPPING CONTAINER MODIFICATIONS Page Two I
3,.
KH-2 containers has a maximum keff = 0.96, and that a 9 x 8 x 2 array of damaged KM-2 packages has a maximum keff = 0.94.
L The KM-2 container is virtually identical to the BB-250-2 container except for the size of the inner containment.
Since the inner container of the 88-250-2 is smaller, the application of the BNWL array calculations to an array of BB-250-2 containers is conservative.
Since optimum conditions were used in the array calculations the shape of the' array does not need to be evaluated. The controlling factor is the number of containers present.
Since the array of BB-250-2 container is limited to 70, which is the same number as the array of KM-2 containers, the application of the BNWL calcu-lations is conservative. Thus, the shipment of BB-250-2 containers may be assigned the same transport index of 0.7 in meeting the Fissile Class II i
standards.
I
References:
?
1.
Kerr-McGee Corporation Amendment Application No.17 to License SNM-928
[
i (Docket 70-925), November 10,1969.
, 2.
License No. SNM-928 Amendment No. 71-11 (Docket 70-925), December 11,1969.
3.
License No. SNM-338, Amendment No. 71-40 (Docket 70-337) September 20, 1971.
A*
p t
,I l
0 p.'
9
/
soun g Ano sau i----
...., ~,,...... -.... -
m g
I A"'".a._ -m MATERIALS DATA INPUT REFERENCE COPY r
F ing m-pty3mygM;;==wn- -
--K f,. 4... ' :
n --- q m
_a,._
,$,M, 5 $
,uu.t.
$TE eao6 amu ccotiraiu m >
a v
h,3 ;..
g oont unit co ract no.
om atout.1 acc o l
070=40135 03093 06-06-72 i
iH :
$FCOND ARY PROGRAM CODES:
~ I s.?
el 82 83 84 85 Y, 53,j-P L/y. ','f
. 1-
- .i.
naut maut
- ,4 ; '. '
j f.
.[p,,.2 h
"^"*
"^"E 1
.h:.
.f
((
maue naut i-,,
9 j<
d SL oaGaNI,a rloN N AMt
' t ;. 'g mme
_2
.s-
% o_
4 s
TYPE OF ORG ANIZ A TION s'
orpaarutur one suntau e
- u. s. sovtamutar astucy toucationat sustituTion t-h 1*
.b}.. ;.e utoicaL institution K
inoust l l ointa 3
.uiso,...... m c i,,
,, m
,i, cm 609 North Warren Aweene Apolle PA 15413 Yyfp./
.,;, 'y 9,
meeucant s couuunicario oano; c u s sir ica t ion auis to ro:
auutrias awo. no.
06-02-72 U
't
.M h
Enclosures:
y Drawings 10F578 and 10C1097 I'b c'.0 7
G UNLL ASSIFIEO DESCRIP TION:
i Ltr. Req. an amendment to d authorize the delivery of snm to a carrier for j
transport in a modified Westinghouse Shipping Container Model BB-250-2.
e i
^
015 T R IB U T IO N A
2 RO g
1 PAR y
DO NOT REyoy3 a
f ACKNOW13DG]J s
OT HE R RE F E RR ALS NAME DATE NAME DATE MacDonald 6-6 1 Reg. File cy 1 PDR e
2 Extras jb t
m i
w
- M
-