ML20141C260

From kanterella
Jump to navigation Jump to search
Forwards LER 97-026-00 Re Failure to Establish Operability of RCS Average Temp Instrumentation Input to MSL Isolation Function During Plant Conditions Required by TS Table 15.3.5-4 Item 2.b Operability Requirements
Date released: 06/03/2020 Download: ML20141C260


:on 970521,discovered TS Violation of Operability Requirement of MSL Isolation.Caused by Inadequate Consideration for Operability of All Required Functions.Verified Low RCS Sys Average Temp
ML20141C266
Person / Time
Site: Point Beach 
Issue date: 06/19/1997
From: Castell C
WISCONSIN ELECTRIC POWER CO.
To:
References
Download: ML20141C266 (5)
Forwards LER 97-026-00 Re Failure to Establish Operability of RCS Average Temp Instrumentation Input to MSL Isolation Function During Plant Conditions Required by TS Table 15.3.5-4 Item 2.b Operability Requirements
ML20141C254
Person / Time
Site: Point Beach 
Issue date: 06/19/1997
From: Dante Johnson
WISCONSIN ELECTRIC POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML20141C254 (1)