_ - _ _ _ _ _ - _ -

OPERATING DATA REPORT DOCKET NO. 50-266 DATE: 04/29/97

?

COMPLETED BY: M. B. Koudelka l

TELEPHONE: 414 755-6480 OPERATING STATUS

1. UNIT NAME: POINT BEACH NUCLEAR PLANT - UNIT 1

. NOTES

2. REPORTING PERIOD: March - 1997
3. LICENSED THERMAL POWER (MWT): 1513.5
4. NAMEPLATE RATING (GROSS MWE): 523.8
5. DESIGN ELECTRICAL RATING (NET MWE): 497.0
6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 509.0
7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): 485.0 i
8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:

NA

9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): NA l
10. REASONS FOR RESTRICTIONS, (IF ANY)-

NA f

THIS MONTH YEAR TO DATE CUMULATIVE F

5

11. HOURS IN REPORTING PERIOD 744.0 2,160.0 231,432.0
12. NUMBER OF HOURS REACTOR WAS CRITICAL 0.0 1,173.6 194,047.5
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 667.3
14. HOURS GENERATOR ON LINE 0.0 1,151.0 190,806.0 t
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 846.9

[

16. GROSS THERMAL ENERGY GENERATED (MWH) 0.0 1,558,331.0 271.052,716.0 r
17. GROSS ELECTRICAL ENERGY GENERATED 0.0 534,720.0 91,625.810.0
18. NET ELECTRICAL ENERGY GENERATED (MWH) 0.0 497,884.0 87,354.303.5

[

19. UNIT SERVICE FACTOR 0.0 %

53.3 %

82.4 %

20. UNIT AVAILABILITY FACTOR 0.0 %

53.3 %

. 82.8%

-[

j

21. UNIT CAPACITY FACTOR (USING MDC NET) 0.0 %

47.5 %

77.5 %

l

22. UNIT CAPACITY FACTOR (USING DER NET) 0.0 %

46.4 %

75.9 %

23. UNIT FORCED OUTAGE RATE -

100.0 %

46.7%

1.9 %

24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE. DATE. AND DURATION OF EACHl:

Refuehng. 09/06/97,49 days

25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:

i 07/01/97

[

DATA REPORTED AND FACTORS CALCULATED AS REQUESTED IN NRC LETTER DATED SEPTEMBER 22,1977 l

9705160212 970506 PDR ADOCK 05000266-R PDR

[

- -