ML20141A183

From kanterella
Jump to navigation Jump to search
Discusses Procedures for Instituting Operational,Small Error,Large Error & Basic Model Corrections for Source Term Code Package,Per 850904 Memo
ML20141A183
Person / Time
Issue date: 11/13/1985
From: Silberberg M
NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
To: Saffell B
Battelle Memorial Institute, COLUMBUS LABORATORIES
Shared Package
ML20140J438 List:
References
FOIA-85-772 NUDOCS 8604040410
Download: ML20141A183 (3)


Text

Subj Circ jn

~,

Chron 0'*"'"

~

NOV 131985 r/f MSilberberg RMargulies MErnst Mr. Bernard F. Saffell, Jr.

JMitchell Battelle Columbus Laboratory OEBassett 505 King Avenue WMorrison j

Columbus, OH 43201 RMinogue 1

Dross

Dear Mr. Saffell:

In a memorandum titled Memo of Understanding on Code Package, dated September 4,1985, and widely circulated, we commented on procedures for making changes to the Source Term Code Package (Task #9 of FIN-B7499).

Because of the importance of STCP to current NRC betivities and because of the involvement of another laboratory (BNL) with STCP, it is important that any changes made to STCP be made deliberately and with full knowledge of all parties involved. The following paragraphs will discuss in some detail the desired procedures for making changes.

Four types of changes are envisioned and may be needed from time to time.

These are as follows:

(1) Operational Changes that are plant specific and need to be made in order for the code run to proceed.

(2) Small Error Corrections, which correct for clear mistakes, but have only a small impact 4

on bottom-line results.

(3) Large Error Corrections, which correct for clear mistakes that have a large impact on bottom-line results.

(4) Basic l

Model Changes dealing with the mathematical equations that describe physical phenomena. The procedures for making these four types of changes will be discussed in turn.

(1) Operational Changes These changes are to be made by BCL in the same manner that code input and systems modeling (control volume definition) are done by BCL. These changes are to be provided explicitly (i.e., highlighted) to BNL for review and auditing along with input and output values under the existing BNL veri-fication program (FIN-A3290).

(2) Small Error Changes These changes should be made in the updated version of the code, but not j

in the reference version of the code being used for NRC analyses (namely, the i

NUREG-1150 calculations.and later production calculations for RES and NRR).

From time to time (hopefully, not more frequently than 6 mos.) it will be desirable to upgrade the reference version to the status of the updated version (see attached figure). When BCL feels that such an upgrading is warranted, BCL (Task #9 FIN-B7499) should obtain BNL's (FIN-A3290) concurrence and forward the recommendation to NRC's Fuel System.s Research Branch for approval. During i

the course of the NUREG-1150 calculations, FSR8 will obtain the concurrence of M. Ernst, Deputy Director, DRA0 in all such considerations.

g 40 g o 860218 SHOLLY85-772 PDR

Mr: Bernard F. Saffell, Jr. NOV 131985

~

i (3) Large Error Corrections The need for such corrections should be brought to the immediate attention of BNL and hRC. Battelle should also assess the impact of such errors on previous calculations and notify BNL and NRC of the impact.

Changes to correct the error should be formulated and proposed to NRC with BNL concurrence.

The Fuel Systems Research Branch will obtain the required DRA0 concurrence and act on such recommendations promptly.

(4) Basic Model Changes These changes are to be treated in the manner that Small Error Corrections and Large Error Corrections are treated, depending on the impact of the model change (i.e., small or large).

In accordance with this procedure, I have l

checked with BNL and DRA0 and determined that approval of the recent change to the decay heat model would not be' forthcoming. Therefore, we ask that BCL return the decay heat model to the earlier form in agreement with our letter of August 29, 1985. Some assessment should be made of the impact of the interim model on the affected sequences for Sequoyah, Grand Gulf, and Surry.

The substance of the above paragraphs should be incorporated in the configuration control effort of Task #9 of FIN-87499. A description of this effort, according i

to existing work plans, is to be included in one of the early FY 86 deliverables to the NRC.

Sincerely,

~

Originai Sipsd By M. Silberberg, Branch Chief Fuel Systems Research Branch Division of Accident Evaluation Office of Nuclear Regulatory Research

Enclosure:

Figure cc:

A. Benjamin, SNL D. Williams, SNL R. Denning, BCL P. Cybulskis, BCL J. Gieseke, BCL R. Bari, BNL T. Prctt, BNL DAE:FSRB DAE:FSRB DRA0:RRBR Meyer:md Silberberg Margulies 11/8/85 11////5 11/t2/85

')((.