j 3 0 Distribution:
OCT 2 81985 subj Circ Chron anch r/f RHeyer eyer r/f MSilberberg Mr. Bernard F. Saffell, Jr.
OEBassett Program Manager WMorrison Battelle Columbus Laboratories RMinogue 505 King Avenue Dross Columbus, OH 43201
Dear Mr. Saffell:
This letter is to confirm our verbal request, of July 31, 1985 for a change to the control-rod vaporization model in the Source Term Code Package.
The specific changes in the CORSOR code are accomplished by multiplying the release fraction FREL (see p.8 of the CORSOR User's Manual, NUREG/CR-4173) by 0.1 for silver and indium and by 0.7 for cadmium. This results in a ten-fold reduction in the amount of silver and indium aerosolized and a modest reduction in the cadmium release.
The basis for the original control-rod aerosol model was given in an ORNL letter report by Lorenz, Beahm, and Wichner dated February 28, 1983 (see R. P. Wichner, ORNL, letter to M. Jankowski, NRC, February 28,1983). The ab3ve modification was recommended by Lorenz based on more recent data, and the basis for this modification is described in the enclosed letter (R. A.
Lorenz, ORNL, letter to R. O. Meyer, NRC, Oct'ober 22,1985). Additional justification for a large reduction in control-rod silver releases is given in an enclosed memorandum entitled " Vaporization and Aerosol Generation from Silver Alloy Control Rods" (R. O. Meyer, NRC, memorandum to M. Silberberg, March 30, 1984).
Sincerely, Original Sipad 3y
~
M. Silberberg, Branch Chief Fuel Systems Research Branch Division of Accident Evaluation.
Office of Nuclear Regulator'y Pesearch
Enclosures:
As stated cc:
D. Ross, NRC R. Bari, BNL g, L (0, Q
,c /3,/g
- 0. E. Bassett, NRC T. Pratt, BNL M. Ernst, NRC A. Benjamin, SNL CM dL b "hMs" T. Margulies, NRC D. Powers, SNL
.g ggj/gf-L. Chan, NRC T. Kress, ORNL J. Mitchell,'iRC R. Lorenz, ORNL
'f g9
,,/f[ff R. Denning, BCL R. Wichner, ORNL J. Gieseke, BCL D. Osetek, INEL P. Cybulskis, BCL
. ~I5555RB-5IiiF5f-----~~ ~---~ ~ ~ ~~------
Meyer:md Silberberg 10/25/85 10///85 8604040390 B60210 PDR FOIA d
8 SHOLLYSS-772 PDR
/