ML20140F623

From kanterella
Jump to navigation Jump to search
Forwards Documents Re Snp to Be Placed on Docket & in PDR
Date released: 06/02/2020 Download: ML20140F623


Forwards P Blanch Comments Re Snp Pressurizer Draindown Event for Review
ML20140F647
Person / Time
Site: Sequoyah 
Issue date: 05/07/1997
From: Amy Cubbage
NRC (Affiliation Not Assigned)
To: HERNAN R W
NRC (Affiliation Not Assigned)
References
Download: ML20140F647 (2)
Forwards P Blanch Comments on TVA Evaluation of 970324 Pressurizer Draindown Event.Disagrees W/Conclusion That TVA Failed to Identify Root Cause
ML20140F635
Person / Time
Site: Sequoyah 
Issue date: 05/05/1997
From: Hernan R
NRC (Affiliation Not Assigned)
To: CHAFFEE A E, HEBDON F J, VARGA S A
NRC (Affiliation Not Assigned)
References
Download: ML20140F635 (1)
Responds to J Zwolinski Note & TVA Investigation Rept Re Snp Pressurizer Drain Down Event of 970324
ML20140F632
Person / Time
Site: Sequoyah 
Issue date: 05/04/1997
From: Blanch P
AFFILIATION NOT ASSIGNED
To: ZWOLINSKI J A
NRC (Affiliation Not Assigned)
References
Download: ML20140F632 (1)
Discusses Snp 1 RCS Partial Drain Down
ML20140F627
Person / Time
Site: Sequoyah 
Issue date: 03/29/1997
From: Blanch P
AFFILIATION NOT ASSIGNED
To: ZWOLINSKI J A
NRC (Affiliation Not Assigned)
References
Download: ML20140F627 (1)
Forwards Documents Re Snp to Be Placed on Docket & in PDR
ML20140F619
Person / Time
Site: Sequoyah 
Issue date: 06/11/1997
From: Hernan R
NRC (Affiliation Not Assigned)
To: MCKNIGHT J
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML20140F619 (1)