ML20140F579

From kanterella
Jump to navigation Jump to search
Submits Addl Comments on K Kodali Re License & Draft Ser.Actual Min edge-to-edge Distance Between Fuel Assemblies in Shipping Containers Approx 2 Inches.Min Spacing Requirement Should Be Deleted from SER & License
ML20140F579
Person / Time
Site: 07003002
Issue date: 06/21/1985
From: Tucker H
DUKE POWER CO.
To: Jennifer Davis, Page R
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
25427, NUDOCS 8507120129
Download: ML20140F579 (6)


Text

- _.

~

DUKE POWER GOMPANY P.O. ascx 33180 CHARLOTTE, N.C, 28242 IIAL B. TUCKER Teternown vica emessnest (704) 373-4531 June 21, 1985

.mu.

m.o-Mr. John G. Davis, Director Office of Nuclear Material Safety & Safeguards 7 ---

U. S. Nuclear Regulatory Commission d M4t -79 Washington, D. C.

20555

}' }

Attention:

Mr. R. G. Page, Chief cd pb u

Uranium Fuel Licensing Branch c

Re: Catawba Nuclear Station, Unit 2 SE Docket No. 50-414 g

Special Nuclear Material License Application u

Dear Mr. Davis:

M In addition to my letter of June 19, 1985, which was in response to the June 7, 1985 letter from Mr. Kishore Kodali, of your staff, we have the following additional comment:

In the Draft SER and proposed License on pages 11 and 21 (and License Condition 16b) there is a proposed restriction of 12 inches on the minimum edge to edge distance between assemblies in the shipping containers. The actual distance between the assemblies in the containers is approximately 2 inches. The approved Westinghouse shipping containers (Certificate of Compliance No. 5450) employ a poison spacer material which is between the fuel assemblies and will preclude inadvertent criticality. We propose deleting the minimum edge to edge spacing requirement for the shipping container array from the

]

SER and the License.

If there are any questions regarding this information, please contact Mr. Roger W. Quellette at (704)373-7530.

Very truly yours, A'l yW g

O Hal B. Tucker p

hg RWO: sib Rygg b :

'yn y

/f cc:

Dr. J. Nelson Grace, Regional Administrator

~.,

U. S. Nuclear Regulatory Commission s

Region II N

' '/

~' /

101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 w-

[

Mb 8507120129 850621 ADOCK0700g2 PDR C

9 M%$

O,j'p,,

4

),7,

' D.

, x'a.

o,_ O.,m, p. % N.2, f

..x N\\g'd

<"c -N/

g g

4_ D J

s N, N

's

/p;Ng.

'N

_q

'N J

s

\\

If k, if J

4 x;

x 7,N

/

o

.N

,g

t., N

'a4

\\ N

  1. x;x g';xs4 xyxyx vts x

y j

. m.

t I

i

Mr. John G. Davis, Director June 21, 1985 l

<Page Two r

cc: Robert Guild..Esq.

P. O. Box 12097 Charleston, South Carolina 29412 NRC Resident Inspector 4

Catawba Nuclear Station 4

i Palmetto Alliance -

2135 Devine Street Columbis, South Carolina 29205 Mr. Jesse L.'Riley Carolina Environmental ^ Study Group 854 Henley Place Charlotte, North Carolina 28207 1

i I

i i

i i

b i

4 l

i

. ~.

11

g. New Fuel Storage Racks in the New Fuel Storage Vault, and
h. Spent Fuel Storage Racks in the Spent Fuel Storage. Facility.

OPC's application specifies that no more than two fuel assemblies shall be out of their shipping containers or storage racks at one time.

l Calculations have indicated that two assem%11es could be made critical at optimum conditions of water moderation and reflection; however, one assembly, separated from another assembly by >12 inches of spacing cannot be made critical under any conditions. Therefore, the staff recommends the 3

following license condition limiting the number of fuel assemblies out of storage and the minimum distance from each other and from all other fuel:

Condition 16a. No more than two fuel assemblies shall be out of approved shipping containers or fuel assembly storage racks at any one-time.

b. The minimum edge-to edge distance between the'two fuel assemblies,.... _,-,. 3 __.............,,and the storage A

rack arrays shall be 12 inches.

be.fcamen B.

Shiocino Containers The fresh fuel assemblies will be temporarily stored in shipping containers in the fuel' receiving area. The shipping containers are authorized for I

21 a.

New Assembly Handling Fixture b.

Rod Cluster Control Assembly (RCCA) Handling Fixture c.

New Fuel Elevator d.

Spent Fuel Pool Manipulator Crane e.

Indexing of Spent Fuel Pool Manipulator Crane f.

Whiting 10 Ton Crane g.

New Fuel Storage Racks in the New Fuel Storage Vault, and h.

Spent Fuel Storage Racks in the Spent Fuel Storage Facility.

Condition 16.

a.

No more than two fuel assemblies shall be out of approved shipping containers or fuel assembly storage racks at any one time, b.

The minimum edge-to-edge distance between the two fuel assemblies

--f +- " ;', r.ni.; _,. _,. and storage rack arrays shall be 12 inches.

bdween Condition 17.

Fuel assemblies shall be stored in such a manner that water would drain freely from the assemblies in the event of flooding and subsequent draining of the fuel storage area.

y

,g,- - _ _ _

m _

mm,r m

m.cm rm m, m

-....mm NR Ferm 374A U.S. NUCLEAR REGULATORY CoMMISSloN PACE 3

or 3

. oes

*""""'b

li MATERIALS LICENSE SNM-195&g I

SUPPLEMENTARY SHEET g,,,,,,,g,f,,,,,,,,,,,,

70-3002 A

l W

I I

16. a.

No more than two fuel assemblies shall be out of approved shipping containers I

l or fuel assembly storage racks at any one time.

l l

b.

The minimum edge-to-edge distance between the two fuel assemblies,W I

I di;;i n; _.....i.;cany, a nd^W3ece n the storage rack arrays shall be 12 inches.

6 I

l

17. Fuel assemblies shall be stored in such a manner that water would drain freely I

l from the assemblies in the event qf oogng-J h[ quent draining of the subse I

C, t i I

fuel storage area.

'V I

b l

18. New fuel assemblies mah stored in the Spent Fuel Sto Facility subject to I

i the following condit.io?fs:

g i,' $

1 A

.1

,/

The maximum U-24% enrichaftk shall be 3.15 wjo I

a.

/

I

.u

.T 1

.; A f j'

()

The fuel asseplies shal1-h toredMn d c(

rhoard pat b.

y D<yu-

\\

n g

The Reactor Eng.ineer shaltjeN,porrecM,

'a'ssembly logion a fter g

c.

y

- \\.,.TT I T t va-3's lR insertion of each assImbly into.ild Ot9 ne(storage. rack A accordance 9

i n

.v a4s

.;3 I

i with a prepared written.koce(ur i 2 ;e $hbby..tM Superinjendent of

~

-3 Opera tions.

&{ f

~ ' '

'?.

d.

An independent loadig,$erification shall be made.by a Quality Control i

Inspector.

(

I e.

The Reactor Engineer and the Quality Control Inspector shall each sign i

l a document assuring proper storage of each fuel assembly.

j i

19. The licensee is hereby exempted from the provisions of 10 CFR 70.24 insofar l

I as this section applies to materials held under this license.

l I

20. The licensee shall comply with provisions of Annex A, " License Condition I

for Leak Testing Sealed Plutonium Sources."

l i

1 I

i il

- -