Informs That Operation of Temporary Reactor Vessel Water Filtration Sys Acceptable,Per SER Submitted on 860206.Only Sources of Water Containing More than 4,350 Ppm Boron May Be Processed Through or Stored in Sys
ML20140C797
Person / Time
Site: Crane 
Issue date: 03/18/1986
From: Travers W
Office of Nuclear Reactor Regulation
To: Standerfer F
GENERAL PUBLIC UTILITIES CORP.
References
CON-NRC-TMI-86-086, CON-NRC-TMI-86-86 NUDOCS 8603250487
Download: ML20140C797 (2)


Text

._. -

i DN 50-320

TMI HQ r/f TMI Site r/f March 18, 1986 WDTravers NRC/THI 86-086 MTMasnik

{

RCook CCowgill

~

LChandler i

Docket No. 50-320 IE ACRS M-town Office i

Mr. F. R. Standerfer Service List

{

Vice President / Director, TMI-2 GPU Nuclear Corporation P. O. Box 480 i

Middletown, PA 17057

Dear Mr. Standerfer:

Subject:

THI-2 " Temporary Reactor Vessel Filtration System" 1

References:

(a) GPUN letter, F. R. Standerfer ta W. D. Travers, THI-2 Temporary Reactor Vessel Water Filtration System", 4410-86-L-0029, dated February 6, 1986 (b) HRC letter W. D. Travers to F. R. Standerfer

" Safety Evaluation Report for the TRVHFS" NRC/THI 86-015 dated February 7,1986 (c) GPUN letter F. R. Standerfor to W. D. Travers, "TMI-2 Temporary Reactor. Vessel Water Filtration System - Revision 1", 4410-86-L-0047, dated March 6, 1986 (d) GPUN letter F. R. Standerfer to B. J. Snyder with attached " Reactor Coolant System Criticality Report" 4410-84-L-0199 dited November 8, 1984 (e) NRC letter B. J. Snyder to F. R. Standerfer re

" Reactor Coolant System Criticality Report" dated March 15, 1985 Reference (a) submitted the Safety Evaluation Report (SER) for the THI-2 i

Temporary Reactor Vessel Water Filtration System (TRVWFS) to the NRC staff for i

approval. The NRC staff safety evaluation and approval were docuwnted.in reference (b). Reference (c) forwarded a revised SER for the system for review and approval.

4 We have reviewed the revised SER and we approve continued operations of the i

system with certain restrictions and administrative controls as discussed below. Following further discussions between our staffs, information transfer j

regarding fission product transport assumptions and dose conversion factors and NRC staff review of this area we may remove these restrictions.

i The only sources of water passing through or contained in the TRVWFS including the waste storage drum are horated to greater than' 4350 ppm B.

These sources, t

the reactor coolant system (RCS) and borated water storage tank BWST, are t

maintained at a nominal 5000 ppm B with a technical specification minimum of 1

ovveCa >

. 7..

" " " ^ " "

  • B603250407 860318 DR ADOCK O O

unc ropu ne no-son nacu ono OFFICIAL RECORD COPY

lir. F. R. Standerfer. flarch 18, 1986 4350 ppm B.

References (d) and (c) provide a bounding criticality safety evaluation and f1RC approval of a configuration nuch more restrictive than any attainable by the TRVWFS, provided that the greater than 4350 ppm B condition is met.

The following restrictions apply to the continued operation of the TRVUFS:

(1) Only sources of water containing 2: 4350 ppa B may be processed through or stored in the TRVHFS.

(2) The waste storage drua must be sampled and analyzed for fissile material content prior to solidification or transfer to another container or systen.

System aparating procedures and procedures delineating waste storage drum sampling and analysis are subject to approval per Technical Specification 6.8.2.

Sincerely, ORIGINAL SIGNED BY:

y(illiam D. Travers William D. Travers Director Till-2 Cleanup Pro.iect Directorate cc: