Revised Application for Amend to License NPF-12,changing Tech Spec Section 3/4.4.5, Steam Generators, Requirement 4.4.5.2,Item b.1 to Clarify Inservice Insp Criteria Re Repair of Steam Generator Tubes as Alternate to Plugging
ML20140C027
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 03/18/1986
From: Nauman D
SOUTH CAROLINA ELECTRIC & GAS CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
Shared Package
ML20140C033 List:
References
NUDOCS 8603250093
Download: ML20140C027 (1)


Text

-

, .d South Carolina Electric & Gas Company Dan A.Neuman

  • P.O. Box 764 V!ca President 1 Columtwa, 29218 Nuclear operations J sesac

- n, March 18, 1986 ,

Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Comission Washington,'DC 20555

Subject:

Virgil C. Sumer Nuclear Station Docket No. 50/395 Operating License No. NPF-12 Steam Generator Tube Repair

Dear Mr. Denton:

South Carolina Electric and Gas (SCE&G) subnitted a request to revise the Virgil C. Staner Nuclear Station Technical Specification (T.S.) relative to steam generator tube repair per letter from D. A. Nauman to H. R. Denton dated January 16, 1986. The proposed T.S. revision will permit the repair of steam generator tubes as an alternative to tube plugging. As a result of a subsequent review, SCE&G feels that fbether revision will be necessary to section. 3/4.4.5, " Steam

' Generators," Requirement 4.4.5.2, its b.1. This change is identified on attached marked-up T.S. page 3/4 4-12.

This revision is intended to clarify the inservice inspection criteria. The no significant hazards determination and remaining T.S. revisions previously subnitted with the January 16 letter remain applicable.

This change has been reviewed and approved by both the Plant Safety Review Committee and the Nuclear Safety Review Comittee. If you should have any further questions, please advise.

tr ours, om en DB4: DAN:tdh c: V. C. Sumer R. M.- Campbell O

0. W. Dixon, 'Jr./T. C. Nichols, Jr. K. E. Nodland 1 E. H. Crews, Jr. R. A. Stough _ l I E. C. Roberts G. O. Percival-J. G. Connelly, Jr. R. L. Prevatte W. A. Williams, Jr. J. B. Knotts, Jr.-

J. Nelson Grace H. G. Shealy Group Managers ## NPCF _ p.

O. S. Bradham D. R. Moore File p .$)

C. A. Price 4-C. L. Ligon (NSRC) g.g .

h P.

5

]