RG 1.99 Revision Evaluation Effort Public Meeting May 19, 2020
Key Messages
- Results: Fleetwide implementation of a revised RG may not be necessary.
- Questions for certain transients (PWR cooldowns on licensed P-T limits and BWR leak tests with higher cooldown rates) - industry input could help.
- Framework of a potential alternative RG 1.99 has been developed.
- Potential burden reduction for some plants - could benefit from industry and licensee input.
2
Purpose of this Meeting
- The NRC staff is holding this meeting to solicit stakeholder feedback on the following topics:
- Elements of the potential alternative RG 1.99.
- Whether potential for burden reduction from a potential alternative regulatory guide would be beneficial to licensees.
- Whether industry can provide certain information to enable the staff to verify risk analysis conclusions.
3
Contents of this Presentation
- Motivation for evaluation effort
- Elements and technical basis for a potential alternative RG
- Fleet Impact/Safety Impact Analysis
- Implementation 4
Motivation for Revision Evaluation Effort 5
Events to Date
- Technical letter report1 (TLR) identified several deficiencies in RG 1.99, Rev.
2.
- Most significant is non-conservatism of RTNDT at high fluence 6x10 19 n/cm2 (some PWRs reach during SLR)
- TLR reviewed by ACRS Subcommittee on August 22, 2019 (ML19260E007) and Full Committee November 6, 2019.
- The NRC staff is currently evaluating the need to develop an alternative to RG 1.99, Rev. 2.
- The NRC staff has not initiated a formal revision process for RG 1.99, Rev. 2.
6 1 - Assessment of the Continued Adequacy of Revision 2 of Regulatory Guide 1.99 -
Technical Letter Report, July 31, 2019, ADAMS Accession Number ML19203A089
RTNDT Results 7
Limited weld data at high fluence precludes assessment of whether weld trends with base metals at high fluences.
Assessment based on BASELINE dataset generated by ASTM E10.02.
Dataset includes domestic and international power reactor data (~55%
domestic).
1901 data points In-depth statistical analysis performed.
RTNDT Results
- Primary conclusions:
- Nonconservative high fluence results (base metals)*, becomes prominent at fluences 6x1019 n/cm2.
- Inaccurate low Cu results
- Secondary conclusions:
- Standard deviation of RTNDT () in RG is too low
- Conservative bias in low-to-mid fluences
- Lack of temperature adjustment (inaccuracy) 8
- Limited weld data available at fluences near or above 1x1020 n/cm2 (E > 1MeV)
Credibility Criteria
- RG 1.99, Rev. 2 has five credibility criteria.
- Criteria compare measured data to refit (chemistry factor) RG 1.99 prediction results with a requirement of shape-function of RG 1.99
- If surveillance data is deemed credible, RG 1.99 allows reduction in margin term.
- No action is suggested if data is deemed non-credible; however it is common practice to use surveillance data when it supports a more conservative prediction.
- The criterion typically failed is excessive scatter.*
9
- - One or more surveillance data point outside 2 where is the standard deviation of the ETC (17 °F for base materials and 28 °F for welds)
Credibility Criteria - Issues
- The more surveillance data points, the more likely it is for data to be non-credible due to scatter.
- No documented basis for reduction in margin for credible data.
- High fluence and low Cu data not expected to conform to fluence shape function of RG1.99 and are consequently more likely to be deemed non-credible.
10
Significant TLR Recommendations
- Correcting the nonconservatism in the embrittlement trend curve at higher fluences is the most significant recommendation of the TLR.
- The credibility criteria should also be revised to be more effective (in combination with an improved ETC).
- Several common practices not addressed in the RG should be addressed in a revision, such as use of sister plant data, implementation of credibility criteria, degree-per-degree, etc.
11
Framework Elements and Technical Basis 12
Framework Elements
- Embrittlement Trend Curve
- Use of Surveillance Data
- Margins
- Limitations
- Default Values 13
Embrittlement Trend Correlation
ETCs Evaluated
- Two trend curves were considered as potential replacements for the RG 1.99, Rev. 2 ETC:
- 10 CFR 50.61a (EONY) -
- NRC-approved since incorporated into alternate PTS rule.
- Fit to 855 T41J values from US light water reactor (BWR and PWR) surveillance data through the year 2004
- ASTM E900-15
- Consensus standard.
- US and international surveillance data, 1033 US data, through ~2012 15
Statistical Tests
- Root Mean Square Deviation (RMSD) - a measure of scatter
- Bias-a measure of whether there is a mean overprediction or underprediction of the data by the ETC.
- Ln(L) - Logarithm of Likelihood - a measure of goodness of fit
- Students t-test - used to examine residual trends versus specific variables.
16
Summary of Statistical Test Results When comparing USA results, both ETCs perform similarly; ASTM E900-15 performs significantly better than 10 CFR 50.61a with respect to international data.
Overall E900-15 performs the best with the lowest bias, better high fluence bias, and superior performance with international data (which includes, among other things, a higher percentage of low Cu materials).
In T-test, E900-15 performs the best overall when compared to all data and subsets.
Both ETCs retain some modelling residuals, but 50.61a has considerably more and in a broad array of categories, indicating that E900-15 performs better over a broader range of inputs than 50.61a.
17
Rationale for ETC Selection (1)
For high fluence materials, E900-15 was selected because:
- It produces more accurate predictions of surveillance data at high fluence (> 3x1019 n/cm2).
Based on the statistical comparison, E900 has a small, positive bias for the USA High Fluence subset, while 50.61a underpredicts the same subset.
- It performs better relative to the international data with high fluence.
For new reactor applications, E900-15 was selected because:
- It performs better relative to the international data for the Low Cu category for the statistical measures (RMSD/bias/Ln(L)).
- It performs better performance with regard to T-test results for the Low Cu subset, as well as the input variables Ni, P, and T. This is particularly pertinent to new reactors which will have low Cu, and consequently will be (relatively) more sensitive to other input variables (Ni, P, T, etc.)
18
Rationale for ETC Selection (2)
The E900-15 ETC is based on a larger database, including additional USA surveillance data for 2004-2012 time frame not included in the 50.61a database.
The staff opinion is that statistical performance versus international data should be considered because the international data contains data in certain areas that are important to US plants, but sparse in US data, such as low Cu and high fluence.
The staff did not consider mechanistic elements used in the development of 50.61a to be a significant deciding factor. Insufficient evidence that mechanistic insights improved performance of 50.61a versus E900 was found.
The E900 ETC is expected to provide more accurate predictions of embrittlement in a broader band of temperatures than 50.61a.
19
Summary - ETC Selection
- The ASTM E900-15 and 10 CFR 50.61a ETCs were evaluated as replacements for the RG 1.99, Rev. 2 ETC.
- The decision was based on both quantitative and qualitative factors.
- Primary reasons for choosing E900-15 are:
- Better accuracy for high fluence materials
- Better accuracy for low copper materials 20
Use of Surveillance Data Consistency Checks
Introduction
- Type testing was used to evaluate surveillance data and construct a refit procedure for use with E900.
- Type testing based on construction of 50.61a tests as described in 50.61a and NUREG-2163, but with of E900 (to be replaced with appropriate values from margins effort).
- Type A - Calculate mean residual, compare to 2.33/ criteria (= 1%)
- Type C - Variance less than 2.33 (= 1%)
- Type D - Compare largest and second largest normalized residual and compare to = 1% one-sided test 22
- - Type B test for slope was also conducted but we are proposing not including it. It is described in NUREG-2163
Introduction 23 Problem: How to assess consistency of plant specific data, and leverage it for anomalous situations.
No Failures Type A Type B Type C Type D Any Failures Multiple Failures 100 29 3
44 35 47 41 Question: Which test failures are likely to be found in the field and in what frequency?
Tested 147 materials using data from BASELINE *.
- These were materials with at least 3 surveillance data.
Proposed Refit (1) 24 Challenge: Improve result more than threaten statistical basis for curve shape Proposed solution - mean adjustment Tools:
Statistical consistency check Bias based refit next slide Use 2 margin
Proposed Refit (2) 25
Proposed Refit (3) 26 Why a mean adjustment (bias correction) for refit?
A) Simple procedure B) Clear basis (unirradiated property measurement error, temperature input, etc.)
C) Minimal impact on critical benefit of E900 over RG1.99R2: shape function
Refit Results 27 Check: Does proposed refit work?
Pre-refit:
Retested 147 materials from E900.
Post-Refit:
No Failures Type A Type B Type C Type D Any Failures Multiple Failures 133 0
3 10 7
14 6
Conclusions Most data will pass.
Mean adjustment will improve pass rate without degrading statistical confidence in results
Margins
Structure of Margin Term
- Structure margin term same as RG 1.99, Rev. 2.
- M is the margin term.
- = standard deviation of transition temperature shift
- i = standard deviation of initial RTNDT. Typically allowed to be zero by staff if a heat-specific measured initial RTNDT exists.
- If initial RTNDT was from a database, i is the standard deviation of the database.
29
= 2 2 +
2
Determination of
- For plates and welds,
- = C* (RTNDT)D, where
- RTNDT = TTS (°F) as determined by Equation 1 of E900-15 (converted to °F).
- C and D values are based on fit to root mean square deviation versus TTS for US data from the BASELINE database.
- More appropriate to base C and D on scatter of US data only, vs. E900-15 which used both US and international data.
- For forgings, equation had a flat trend, so simpler just to use a constant SD () based on RMSD of the whole data set, (21.49°F).
30 Product Form C
D Plate 5.112 0.345 Weld 14.936 0.142
Fit for Welds Welds: US - data only fit is similar to E900-15 fit, slightly lower SD at high TTS and opposite at low TTS.
31
Fits for Plate 32 Plate: E900-15 combined plate plus SRM for SD.
Inclusion of SRM with plate results in lower SD for both US and US +
international data.
SRMs have no regulatory purpose and not required to be tested, therefore does not seem appropriate to mix with plate data for purpose of determining SD.
Therefore, C and D were determined based on US plate only.
Default Values
Default Values
- Default values can be used in the RTNDT calculation when certain data is not available.
- Cu, Ni, Mn, P, temperature.
- Selected to be conservative-
- Chemistry values are high
- Temperature is low
- Expect that missing chemistry values will be rare for beltline materials, particularly Cu and Ni.
- Need to use default value for irradiation temperature expected to be rare.
34
Approach
- Determine distribution of values for each variable in BASELINE
- Plotted histograms
- Determined quartiles of data 35
Recommendation - Chemistry Use maximum value from database for Cu, Ni, Mn, P.
- Basis - Considered using an upper 95% value or 75% value. Since values do not appear to be normally distributed, WG decided to use maximum values from distribution.
- These values are conservative, and missing chemistry values are expected to be a rare case.
- WG considered using specification maximum, however specifications do not contain ranges for all elements
- Example, SA-533 does not specify a range for Cu.
Recommended Default Chemistry Values (PWR and BWR) 36 Product Form Cu Ni Mn P
Forgings 0.16 0.86 1.41 0.020 Plate 0.25 0.68 1.65 0.021 Welds 0.41 1.20 1.96 0.024
Recommendation - Temperature (PWRS)
- RG will include guidance to use the reactor inlet or cold leg temperature for irradiation temperature for PWRs
- Use a time-weighted average if temperature changed for different cycles, such as due to power uprates, etc.
- Default value for PWRs: 523 °F (272.8 °C) based on US fleet minimum from BASELINE 37
Recommendation - Temperature (BWRs)
- Use a time-weighted average if temperature changed for different cycles, such as due to power uprates, etc.
- Default value for BWRs: 530 °F (276.7 °C) based on minimum value from BASELINE 38
Limitations
Approach E900-15 specifies limitations on chemistry, fluence and temperature based on the maxima and minima of the database used to develop the trend curve.
A commenter during the ASTM voting process for E900-151 recommended more restrictive limitations based on +/- 3, and warning levels based on +/- 2.
The staff evaluated need for similar limits.
Divide database into two populations based on percentile of all data.
Perform surveillance data consistency checks (Type A, B, C, D) on both populations.
Is there a difference in the proportion of passing and failing the consistency checks?
40 1-Attachment 2 to Appendix E of E900 Adjunct, p. 132-134
Results
- Ran Type A,B,C and D tests for the entire population, 95th, 96th, 97th, 98th and 99th percentiles.
- No statistically significant differences between entire population and any of the other percentiles.
- Therefore, it is not necessary to impose limitations more restrictive than those specified in E900-15, except for temperature.
41
Temperature Limitation
- A minimum temperature limitation of 523 °F (272.8 °C) is recommended.
- This corresponds to the minimum of the US operating fleet, as the data becomes sparse below this temperature.
42
Fleet Impact Analysis
Fleet Impact Study Methodology
- Looked at a smart sample of 21 plants concentrating on high fluence PWRs, with additional plants with low Cu materials and BWRs added to span the fleet chemistry values (Cu, Ni).
- Used licensing basis material inputs (chemistry; fluence; RTNDT(u); licensing basis CF and ART for RG 1.99, Rev. 2).
- Calculated ART resulting from RG 1.99, Rev. 2, and E900-15, including the proposed RG margins and surveillance data tests/refit procedure.
Reference Temperature Results All Materials 45
Reference Temperature Results - Limiting Materials 46 new limiting material refers to the situation where application of the E900-15 ETC causes a different material to have a higher ART than with RG 1.99, Rev. 2.
Potential New Limiting Materials 47 new limiting material refers to the situation where application of the E900-15 ETC causes a different material to have a higher ART than with RG 1.99, Rev. 2.
Reference Temperature Results-Base Metal 48
Reference Temperature Results - Weld Metal 49
Fleet Impact - Summary
- There is a tendency for material reference temperatures to increase when switching from RG 1.99, Rev. 2 to ASTM E900-15.
- ID reference temperatures tend to increase more than the 1/4T reference temperature (ART).
- Base materials are more likely to see increases in reference temperatures.
- Many weld materials see reductions in reference temperatures at fluences <
4x1019 n/cm2.
- Based on the smart sample, only a handful of plant limiting materials will have ESDs* > 50 °F, and these tend to be at fluences ~6x1019 n/cm2.
50 ESD - Embrittlement shift delta
Safety Impact Analysis 51
Objective
- Determine safety impact of a potentially nonconservative material reference temperature (ART or RTPTS) associated with normal cooldown and leak test transients and PTS transients.
- Evaluated potential ETC non-conservatism by calculating the change in the conditional probability of failure (CPF) as a function of the embrittlement shift delta (ESD) (i.e., amount by which the material reference temperature changes using E900-15 vs. RG 1.99, Rev. 2).
52
Method
- Analysis uses FAVOR code.
- Compared to fleet impact study, few limiting materials have ESDs > 50°F.
- Various transients were modeled.
- 1/4T and shallow surface-breaking flaws modeled.
53
Method CPF used as a screening criterion for reasonable assurance that no safety issue exists rather than through-wall cracking frequency (TWCF) due to uncertainty about some event frequencies.
Determined the CPF associated with a nonconservative ETC, for the following scenarios:
- BWR cooldowns following licensed P-T limits,
- BWR saturation cooldowns,
- BWR leak tests,
- PWR PTS transients,
- PWR cooldowns following licensed P-T limits,
- PWR actual plant cooldowns.
54
BWR Leak Test 55
P-T Limits - BWR Cooldown Summary (Licensed P-T limits) 56
P-T Limits - PWR Cooldown Summary (Licensed P-T limits) 57
Actual Cooldowns - P-T Curves 58
Actual Cooldowns 59
Summary of Results 60 Note, all ESDs means range of evaluated in the FAVOR analyses, -40 °F - 193 °F for PWRs and -40 °F to 128 °F for BWRs - corresponds to the 5th through 99th percentiles Transient Type Shallow Flaw 1/4T Flaw Comment BWR P-T Limit Cooldown (C/D)
CPF 10
-6 for all ESDs CPF 10
-6 for ESD 50 °F. CPF may be > 10
-6 for higher ESDs BWRs must cooldown on saturation curve, so C/D on licensed limits not plausible.
BWR Saturation Cooldown CPF 10
-6 for all ESDs CPF 10
-6 for all ESDs BWR Leak Test CPF 10
-6 for all ESDs CPF 10
-6 for ESD > 100 °F Information from industry desired to confirm high cooldown rates are not possible, or code action to prohibit.
PWR P-T Limit Cooldown CPF >10
-6 for ESDs 50 °F CPF > 10
-6 for ESD 20 °F Additional information on event frequencies is desired to confirm TWCF< 10
-6/year.
PWR Cooldown, Actual Transients
<< 10
-6 for most transients n/a PTS n/a n/a All TWCF < 10
-6
Results - BWR
- BWR saturation cooldowns - Low CPF < 10-6.
61
Results - PWR P-T Limits Cooldowns on licensed P-T limits.
- 1/4T flaws - no safety issue for ESD < 20 °F.
- Shallow flaws can have CPF > 10-6 without ESD. ESD of 50-75 °F can increase CPF by an order of magnitude.
- Shallow flaw high CPF is a known issue and is being studied by both NRC and EPRI.
- Frequency of operating on licensed P-T limits is believed to be << 1/year, which is expected to result in TWCF 1x10-6/year for most transients. However, staff would like more information on operational procedures and system constraints that prevent violating the licensed P-T limits.
Actual plant transients
- No significant failure risk.
- Staff would like additional information to confirm that its sample of actual plant transients is representative.
62
PTS Method and Results
- Applied the same method used to develop the technical basis for the alternative PTS rule (NUREG-1874).
- NUREG-1874 defines relationship between maximum RTNDT (RTMAX) and TWCF.
- The TWCF was calculated for three different ETCs (RG 1.99, Rev. 2, E900-15, and 10 CFR 50.61a).
- TWCF < 10-6 /year for the 21-plant smart sample at 72 EFPY fluence, regardless of the ETC model applied.
63
PWR Summary
- Up to 50°F of ESD can conservatively be considered not to significantly increase the failure risk associated with P-T limits in light of additional plant constraints and an evaluation of a small subset of plant transients.
- No safety concern for PTS based on the smart sample evaluation.
- The main areas of uncertainty are:
- The event frequency for impinging on the licensed P-T limits. What controls and procedures are in place to prevent violating licensed P-T limits?
- How representative are the actual transients used in the staffs analysis? Can bounding actual transients be identified?
64
Safety Analysis - Conclusions Based on an 80-year analysis of a smart sample of plants, potentially nonconservative reference temperatures do not represent a significant safety issue in most cases for normal cooldowns, leak tests and PTS transients.
Higher CPF calculated for the following transients:
- Licensed P-T limits for plants with high ESDs.
- BWR leak tests with high ESDs.
- Lower cooling rates are expected to result in lower CPF values.
Additional information desired to help confirm that the risk is low for the high ESD plants.
Safety analysis results do not justify generic implementation of a revised RG based on ASTM E900-15.
65
Implementation 66
Potential for Burden Reduction
- Implementation of an E900-15-based RG has the potential to reduce burden for certain categories of reactors by reducing the reference temperature for a given neutron fluence, which in turn results in less restrictive P-T limits.
- Categories of plants that may see burden reduction include:
- BWRs,
- Low-fluence plants,
- Plants with low-copper content materials,
- Plants for which the limiting material is a weld.
- NRC received a petition for rulemaking from NuScale to implement E900-15 as the ETC for PTS and P-T limits, in lieu of RG 1.99 Rev. 2 with a degree-per-degree adjustment. The staff is currently evaluating the petition.
67
Summary
Feedback Requested on the Following Topics:
- Elements of potential RG framework that have been presented by the
- staff,
- Desire for an alternative to the current RG,
- Provide additional information to verify risk estimates for plants with ESD
> +50 °F (see discussion questions next slide) 69
Additional Information/Discussion Topics PWRs
- What controls and procedures are in place to prevent violating licensed P-T limits?
- How standardized are these controls/procedures?
- Can controls be identified by plant type and design or are they entirely plant specific?
- Is there a way to develop "bounding transients" that are more representative than the P-T limit curve based on the answers to the above questions? Can these be identified for specific design types, for example, Westinghouse 3-loop?
- Is there is a more quantitative way to assess and sample the population of actual plant cooldown transients?
BWR Leak Tests
- Is it physically possible to heat up and cool down on the licensed P-T limits? Are there any physical, Code, or administrative limits to heat-up and cool-down rates?
- Is an ASME Code activity planned to limit leak test heatup and cooldown rates?
70
Next Steps
- Decision on whether to proceed with developing an alternative regulatory guide.
-Consider feedback from industry.
-Further discussions with industry?
-Complete fleet impact study if appropriate.
71
Acronyms/Definitions (1)
ART - Adjusted reference temperature used for pressure-temperature limits (initial RTNDT + RTNDT + margin)
CPF - Conditional probability of failure - Probability that the reactor vessel will fracture through-wall given a certain event occurs.
ESD = embrittlement shift delta - amount by which the material reference temperature changes using E900-15 vs. RG 1.99, Rev. 2 ETC - Embrittlement trend curve - a mathematical relationship defining the relationship of ART to key variables such as chemistry and neutron fluence.
FAVOR - Fracture Analysis of Vessels, Oak Ridge - A probabilistic fracture mechanics computer code.
P-T Limits - Limits on pressure versus temperature for normal operations of a reactor PTS - Pressurized thermal shock, a challenging transient that may occur in PWRs 72
Acronyms/Definitions (2)
RTNDT - The reference temperature, nil-ductility transition.
RTNDT(u) - The initial or unirradiated RTNDT. Per 10 CFR 50, Appendix G, RTNDT(u) is evaluated according to the procedures in the ASME Code, Paragraph NB-2331. NUREG-0800 BTP 5-3 provides an alternative procedure.
RTNDT -The change in RTNDT due to irradiation, defined in RG 1.99, Rev. 2 as the shift in the Charpy curve at the 30 foot-pound level. Also referred to as T41J in this presentation, 41 joules = 30 foot-pounds.
RTPTS - Adjusted reference temperature used for pressurized thermal shock criteria P-T Limits - Limits on pressure versus temperature for normal operations of a reactor TWCF - Through-wall cracking frequency - CPF x event frequency per reactor year 73
Backup Slides 74
Statistical Error Types 75 Residuals between BASELINE data and the ASTM E900-15 ETC are calculated using the best estimate chemistries time weighted operating temperatures. =
Note: All tests were conducted as described in NUREG-2163 (ML18255A118), Section 5.4, with the exception that for all tests was SD determined per Equation [9] of E900-15. The proposed procedure will use the determined per Slide 30.
Type A: Mean Test: If rmean of all of the residuals for heat of material fall below the threshold value,
=
, then there is no Type A error. =
Type B: Slope Test: Plot the residual values for each heat of material on a semi log plot of fluence and calculate the T-statistic using the best-fit slope and standard error of the best-fit slope. =
() if the calculated T-statistic is below the tabulated 1% 1-sided T-statistic value, then there is no Type B error.
Type C: Scatter Test: For each heat of material if
( ) then there is no Type C error.
Type D: Outlier Test:
=
and
=
are the largest and second-largest values of
for each heat of material.
Compare these to and from Table 5-4 (NUREG-2163). If and then there is no Type D error