NRC MONTHLY OPERATING REPORT DOCKET NO.

50-206 UNIT NAME SONGS - 1 DATE September !!. 1985 COMPLETED BY E. R. Stacor TELEPHONE (714) 492-7700 Ext. 86223 OPERATING STATUS

1. Unit Name:

San Onofre Nuclear Generating Station, Unit 1

2. Reporting Period: Au_ gust 1985
3. Licensed Thermal Powerl Kdt):

1347

4. Nameplate Rating (Gross Rde):

45_6

5. Design Electrical Rating (Net Mde):

43_6

6. Maximum Dependable Capacity (Gross R4e):

456

7. Maximum Dependable Capacity (Net Kde):

._436

8. If Changes Occur In Capacity Ratings (Items Number 3 Through 7)

Since Last Report, Give Reasons:

NA

9. Power Level To Which Restricted, If Any (Not MWe):

390

10. Reasons Fcr Restrictions, If Any:

Self-imposed power level limit to control _

stea'n generator tube corrosion.

This Month Yr.-to-Date Cumulative

11. Hours In Reporting Period 744.00

~4_,831.00~

159 655.00~

5 1

12. Number Of Hours Reactor Was Critical 507.28

,927~64 94,247T62

13. Reactor Reserve Shutdown Hours 0

0 0

~ ~ ~

14. Hours Generator On-Line 50'5797~

4,891~27-5MI32T4-

15. Unit Reserve Shutdown Hours 0

0 0

~

16. Gross Thermal Energy Generated (F4H)

WlDT7B836' 5,lisf 6f774T Tli

~~

~9'i6481832T72

17. Gross Electrical Energy Generated (F4H) 182jli1Tbb~ 1,791,932:195 600.d0~

3,118jo34TDo~

18. Net Electrical Energy Generated (HWH)

Bd~ ~36,974_,~645Tdd~

~

19. Unit Service Factor

- ~48.01

20. Unit Availability Factor 68T01~

~ ~8 D 6' 56T70~

8'3T88~

$6!7d'

21. Unit Capacity Factor (Using MDC Net) 66T15~

70T48

~

$3!!2~

~ ~~

- ~ 6.15~

~~ ~~7 0V

22. Unit Capacity Factor (Using DER Net)
23. Unit Forced Outage Rate 6~

ID8~

53T12~

5 21.26"

~

24. Shutdowns Scheduled Over hext 6 Months (Ty~p^e70 ate anTD74tTo~n~of'Mii):

Refueling, November, 385,150-day _ duration.

25. If Shutdown At End Of Report Period, Estimatori Date of Startup: __

9 LOU 85

26. Units In Test Status (Prior To Commercial Opera.f on):

Forecast Achieved INITIAL CRITICALITY NA NA

~~ A ~

h4~~

INITIAL ELECTRICITY N

COMMERCIAL OPERATION

~~NAZ ZN4~-

gL) 6794u 0511100/201 050(131 i k\\

780H ADOCK 05000204 i\\

N l'DN

r-AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.

50-206 UNIT SONGS - 1 DATE Septemhet_1L__1185 COMPLETED BY E. R. Siacor TELEPHONE

[714)_492-770_0_.

Ext. 86223 MONTH: August 1985 OAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1 380.13 17 378.08 2

378.42 18 376.83 3

378.08 19 375.67 4

270.71 20 373.21 5

326.13 21 346.38 6

386.29 22 3.86 7

395JO 23 0.00 8

382.21 24 0.00 9

379.63 25

0. 0_0 10 323.88 26

_0._00 11 373.63 27 0.00 12 369.38 28 0.00 13 371.54 29 0.00 14 377.38 30 0.00 15 377.00 31 0.00 16 376.42 6794u

;!);

I tI i

(hr et '

,tl((*l!f.;It!,

l?'I i

P

~

+

~

y a

e a

d g

- oa r3e 2ctk w

e.i 9i a

n l ye t

f oaob mudl 5

WNr rao 8

n u

orbt o gd T fd a

9 inn r yA e 1

3 tiad eH?s

?

e e ct n p $

o?

v c ea1 m8A 3

.a j6 n

pl oe 3

8 1

f i

1 r/8 t

e suos ttV5 9

o/

c r ncNe.

sH8 1

eor r c-ir x

ey -

e a2 t

rtu ifog nSrV 3

i i9 x

r c rCobn iH 0

i b

s4E one o

na 8

i l

5 u1 6

5 CoR fhgrt o pd 0sE tnes fien i

2 c E H_1

&tt ruite ftra d

Np 84 cn eonat oc,k t

0oe eAe wSaw 5sS L7 e

S

(

s v o e e njta u e pdl rv ense E

r

.EEYE a r nccl kiel E

OMTBN C P da sa a T

E NAA O e

,nv ty t I

nDDH chse tee T

[P u t pd p tevn 4*

Ei TE drmno ifl n kl EL eouot naao Cr LE RNPcs USVb a

Ou PT D

M O

t C

n m

e

.h e4

,o "0 t n e mr

)

o d V

afh2 n

p o P

H

.r t

nsi e

S m C S

mcnnfira M

o aSoao ul I

C r

iM rop O

cct neHs T

5 Siasot E C

8 tuuia4(

U 9 m4 anote2 ll D

1 e e

aamiicr r

E t

d E

Q dus otvuGte a

R t

s o k

B onrtned sh s

y C haauorerat R u S

tMMACPRoPO E

c e-W a P1034 S 6

O A P

3 v

H D

I M m R.

A o I o A

A n

n Lk M

M o

S M r t

i W a a

O o n

l og 3 ms D P f

u f<

n r

a a

din o x

S otw t

E hto c 1

r teed a

)

e

)

eh e

n s n i

w a

MS R

n i

i c

a e a c

l l

w 2

p ni p

w n

s JL m

w o

E i

E s

B 8

(t tr

(

J a

s c e

ee ig r

F rT rn o u

ti r) r snern l

n io eivEi o) a Eas a

s 3

f e rtl l

i tr 0

c yT aap m

au tngr rnu ro O

8 nanortoE uH 3

enatoss(

D(

2 mel atet w

ptet ana r

.w n i n u :. r n re s

ouafgeaet n

a E M. e e p d p t sqa 1

EFOAOC w

r e

e-p S

5 RABCDEfCS t

y w

T 2

d e

4 2

e t

0 2

l a

3 S

du D

0 C

ed 5

S ce 8

S rh oc fS u

F5 4

w o

9

+

b 9

0 1

7 I

8 9

6 s

O lliliIi I

-I

,jlll

F

SUMMARY

OF OPERATING EXPERIENCE FOR THE MONTH DOCKET 50-206 UNIT SONGS - 1 DATE September 11, 1985 COMPLETED BY E. R. Stacor TE_LEPHONE (714)_492-7700,

Ext. 86223 DATE TIME EVENT August 1 0001 Unit is in Mode 1 at 92.5% reactor power. Turbine load is 402 MWe gross.

August 4 0630 Commenced load reduction for inspection of North and South Circulating Water Pumos and cleaning of No. 1 and No. 3 condenser water boxes.

August 4 0812 Reactor power is 54%. Turbine load is 235 MWe gross.

August 4 2210 Commenced repairs to two North Circulating Water Pump suction bell bolts found broken.

August 5 0920 Commenced load increase following completion of repairs to the North Circulating Water Pump.

August 5 1014 Reactor Power is 934.

Turbine load is 407 MWe gross.

August 21 2004 Commenced load reduction for Safety Injection System Hydraulic Valve surveillance testing and repair of HV-852A body to bonnet leak.

August 22 0158 Unit taken off line.

Entered Mode 2.

August 22 0317 Entered Mode 3.

S!$ Hydraulic Valve testing completed satisfactorily.

August 22 2040 Entered Mode 4 August 23 0043 Entered Mode 5 for repair of HV-852A body to bonnet leak.

August 26 1445 Entered Mode 4 following completion of repairs to HV-852A.

August 26 2300 Entered Mode 3.

August 28 1104 Entered Made 2.

August 29 1450 Entered Mode 3 for repairs to $15 Hydraulic Valve HV-853A seat leakage.

August 31 2400 Unit is in Mode 3.

Commenced preparations for Unit Startup following completion of repairs to HV-853A.

6794u

F

~

REFUELING INFORMATION DOCKET NO.

50-206 UNIT SONGS - 1 DATE September 11, 1985 COMPLETED BY E. R. Stacor TELEPHONE (714) 492-7700_..

Ext. 86223 MONTH:

August 1985 1.

Scheduled date for next refueling shutdown.

November 1985 2.

Scheduled date for restart following refueling.

April 1936 3.

Will refueling or resumption of operation thereaf ter require a Technical Specification change or other license amendment?

No What will these be?

NA 4

Scheduled date for submitting proposed licensing action and supporting information.

NA 5.

Important Licensing considerations associated with refueling, e.g. new or different fuel design or supplier, unroviewed design or performance analysis methods, significant changes in fuel design, new operating procedures.

NA 6.

The number of fuel assemblies, a) In the core.

157 b)

In the spent fuel storage pool.

94 7.

Licensed spent fuel storage capacity.

216 Intended change in spent fuel storage capacity.

NONE 8.

Projected date of last refueling that can be discharged to spent fuel storage pool assuming present capacity.

February 1988 6794u

P f[5 Southern California Edison Company SAre ONOFRE NUCL E AR GENER ATING ST ATION P O HOX 120 SAN CLEMENTE. CALIFORNIA 92672 H E kORGAN ffLEPHONE ST&YtON MANAutM (7941 368 624l September 11, 1985 Director Of fice of Management Information and Program Control U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Str:

Subject-Docket No. 50-206 Monthly Operating Report for August 1985 San Onofre Nuclear Generating Station, Unit 1 Enclosed is the Monthly Operating Report as required by Section 6.9.1.c of Appendix A, Technical Specifications to Provisional Operating License DPR-13 for San Onofre Nuclear Generating Station, Unit 1.

Please contact us if we can be of further assistanco.

Sincerely, Mb Enclosures J. B. Martin (Regional Administrator, USNRC Region V) cc:

F. R. Huey (USNRC Senior Resident Inspector, Units 1, 2 and 3)

INPO Records Center l

s, L

-- --~