Forwards Insp Rept 50-160/85-04 on 851028-1101.No Violations or Deviations Noted.Appraisal Indicates Areas That Should Be Evaluated & Considered for Improvement in Emergency Preparedness Program
ML20138Q870
Person / Time
Site: Neely Research Reactor
Issue date: 12/18/1985
From: Walker R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Karam R
Neely Research Reactor, ATLANTA, GA
Shared Package
ML20138Q872 List:
References
NUDOCS 8512300045
Download: ML20138Q870 (2)


See also: IR 05000160/1985004

Text

WS 6f55

'

-

DEC 181985

Georgia Institute of Technology

[TN: Dr. Ratib A. Karam, Director

of Nuclear Research Center

900 Atlantic Drive, N.W.

Atlanta, GA 30332

Gentlemen:

SUBJECT: REPORT NO. 50-160/85-04

On October 28 - November 1, 1985, NRC inspected activities authorized by NRC

Operating License No. R-97 for your Georgia Tech Research Reactor (GTRR) facility.

At the conclusion of the inspection, the findings wev discussed with those

members of your staff identified in the enclosed inspection report.

Areas examined during the inspection are identified in the report. Within these

areas, the inspection consisted of selective < xaminations of procedures and

representative records, interviews with personnel, and observation of activities

in progress.

Within the scope of the inspection, no violations or deviations were identified.

The findings of this appraisal indicate that deficiencies exist in your Emergency

Program. This is discussed in Appendix A, " Emergency Preparedness Deficiencies."

You are requested to submit to this office within 30 days of the date of this

letter, a written statement stating your proposed actions to correct these

deficiencies and the date when compliance will be complete.

This appraisal also indicated that there are areas that should be evaluated and

considered for improvement in your Emerg'ency Preparedness Program. These areas

are discussed in Appendix B, " Emergency Preparedness Improvement Items." We

recognize that an explicit regulatory requirement pertaining to each item in

Appendix B may not currently exist. Notwithstanding this, you are requested to

submit a written statement addressing the results of your consideration of each

of the items in Appendix B. This statement should be submitted in conjunction

with your notification of corrective actions for the deficiencies identified

in Appendix A.

In accordance with 10 CFR 2.790(a), a copy of this letter, its enclosures, and

your. reply will be placed in NRC's Public Document Room upon completion of our

evaluation of the reply.

The responses directed by this letter and the enclosures are not subject to the

clearance procedures of _ the Office of Management and Budget issued under the

Paperwork Reduction Act of 1980,-PL 96-511.

'

8512300045 851218

PDR ADOCK 05000160

G PDR

.g.

.TE01

._. _ . . _ _ _ _ _ .- ~ _ . - . _ . . - .

e

>

Georgia, Institute of Technology 2

Should you have any questions concerning this letter, please contact us.

Sincerely,

Roger D. Walker, Director

Division of Reactor Projects

Enclosures:

1. Emergency Plan Deficiencies

2. Emergency Preparedness

Improvement Items

3. Inspection Report.

No. 50-160/85-04

cc w/encls:

4 . T. E. Stelson, Vice President

-for Research

bcc w/o encls:

vdcense Fee Management Branch

bec w/encis':

EP Section Files'

Document Control Desk

. . St

M . ate of' Georgia

Matthews, EPLB, IE HQS

r

.

,

RII RII RII

JO g#tA

RI

h

-

arston:ht TDecker DCollins J tohr

12/f/85 12/ /85 12//#/85

$ 12/g)/85

I RII RI

ellen PFre ickson DVerrelli '

-12/j]/85 12/ 385~

12/f/85

l

.