ML20138L198

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 50-346/85-30 on 850812-0909.Decision Re Enforcement Action Will Be Forwarded by Separate Correspondence
Date released: 05/31/2020 Download: ML20138L198


Insp Rept 50-346/85-30 on 850812-0909.Violations Identified: Lack of Design Control Measures to Validate Design of Limitorque Valves & Auxiliary Feedwater Pump Turbines.Test Procedures Inadequate for Limitorque Valves Test Program
ML20138L208
Person / Time
Site: Davis Besse 
Issue date: 12/13/1985
From: Jackiw I
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
References
Download: ML20138L208 (11)
Forwards Insp Rept 50-346/85-30 on 850812-0909.Decision Re Enforcement Action Will Be Forwarded by Separate Correspondence
ML20138L194
Person / Time
Site: Davis Besse 
Issue date: 12/13/1985
From: Norelius C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: WILLIAMSON J P
TOLEDO EDISON CO.
References
Download: ML20138L194 (1)