Monthly Operating Rept for Nov 1985
ML20138J683
Person / Time
Site: Salem 
Issue date: 11/30/1985
From: White P, Zupko J
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
NUDOCS 8512170609
Download: ML20138J683 (10)


Text

.. _

f-AVERAGE DAILY UNIT POWER LEVEL Docket No.

50-311 Unit Name Salem # 2 Date Dacember 10,1985 Completed by Pell White Telephone 609-935-6000 Extension 4455 Month November 1985 Day Average Daily Power Level Day Average Daily Power Level (MWe-NET)

(MWe-NET) 1 1101 17 1099 2

1083 18 1099 3

1105 19 1090 4

1100 20 1081 1

5 1099 21 1102 6

1105 22 1088 7

7 1099 23 1080 s

8 1098 24 1096 9

1100 25 1095 4

10 1110 26 1092 11 1101 27 1101 12 1102 28 1100 13 1094 29 1108 14 1093 30 1093 15 1086 31 16 1092 Pg. 8.1-7 R1 l

8512170609 851130 PDR ADOCK 05000311' R

PM s

. m

9 OPERATING DATA REPORT Docket No. 50-311 Date December 10,1985 Telephone 935-6000 Completed by Pell White Extension 4455 Operating Status 1.

Unit Name Salem No. 2 Notes 2.

Reporting Period November 1985 3.

Licensed Thermal Power (MWt) 3411 4.

Nameplate Rating (Gross MWe) 1170 5.

Design Electrical Rating (Net MWe)

IITY 6.

Maximum Dependable Capacity (Gross MWe)1149 7.

Maximum Dependable Capacity (Net MWe) 1106 8.

If Changes Occur in Capacity Ratings (items 3 through 7) since Last Report, Give Reason N/A 9.

Power Level to Which Restricted, if any (Net MWe)

N/A

10. Reasons for Restrictions, if any N/A This Month Year to Date Cumulative
11. Hours in Reporting Period 720 8016 36241
12. No. of Hrs. Reactor was Critical 720 4993.3 20087.9
13. Reactor Reserve Shutdown Hrs.

0 0

3533.6

14. Hours Generator On-Line 720 4686.9 19299
15. Unit Reserve Shutdown Hours 0

0 0

16. Gross Thermal Energy Generated (MWH) 2455831 15208345 58935381
17. Gross Elec. Energy Generated (bOGI) 820710 5028830 19306480
18. Net Elec. Energy Generated (MWH) 789136 4765299 18283135
19. Unit Service Factor 100 58.5 53.3
20. Unit Availability Factor 100 58.5 53.3
21. Unit Capacity Factor (using MDC Net) 99.1 53.7 45.6
22. Unit Capacity Factor (using DER Net) 98.3 53.3 45.2
23. Unit Forced Outage Rate 0.0 38.9 37.5
24. Shutdowns scheduled over next 6 months (type, date and duration of each)

N/A

'25. If shutdown at end of-Report Period, Estimated Date of Startup:

N/A

26. Units in Test Status (Prior to Commercial Operation) :

Forecast Achieved Initial Criticality 6/30/80 8/2/80 Initial Electricity 9/1/80 6/3/81 Commercial' Operation 9/24/80 10/13/81-8-1-7.R2

~

UNIT SHUTDOWN AND POWER REDUCTIONS Docket No. 50-311 REPORT MONTH October 1985

-Unit Ncme Selcm No.2.

Date November 10,1985 Completed by J.P.

Ronafalvy Telephone 609-935-6000.

Extension 4455 Method of Duration Shutting License Cause and Corrective No.

Date Type Hours Reason Down Event System Component Action to 1

2 Reactor Report Code 4 Code 5 Prevent Recurrence

. There were ~ no~ Outages for the month of November resulting in a load reduction of greater than 20%.

I 2' Reason 3 Method 4 Exhibit G 5 Exhibit 1 F: ' Forced A-Equipment Failure-explain 1-Manual Instructions Salem as S: Scheduled B-Maintenance or Test 2-Manual Scram.

for Prepara-Source C-Refueling 3-Automatic Scram. tion of Data D-Regulatory Restriction 4-Continuation of Entry Sheats E-Operator Training & Licensing Exam Previous Outage for Licensee F-Administrative 5-Load Reduction Event Report G-Operational Error-explain 9-Other (LER) File H-Other-explain (NUREG 0161) k- -

F

+

l MAJOR PLANT MODIFICATIONS DOCKET NO.:

50-311 j

REPORT MONTH NOVEMBER 1985 UNIT NAME:

Salem 2 DATE:

December 10, 1985 COMPLETED BY:

J.

Ronafalvy TELEPHONE:

609/339-4455 I

PRINCIPLE SYSTEM SUBJECT i

2EC-2113 Spent Fuel Storage Provide vent holes in swollen Racks-Fuel Handling spent fuel storage cells.

System.

(

i J

s

MAJOR PLANT MODIFICATIONS DOCKET NO.:

50-311 REPORT MONTH NOVEMBER 1985 UNIT NAME: Salem 2 DATE:

December 10, 1985 COMPLETED BY:

J.

Ronafalvy TELEPHONE:

609/339-4455

10CFR 50.59 SAFETY EVALUATION 2EC-2113 The fuel cell inner shroud deformation is due to the build-up of off gases in the Boral poison plates.

When water is present in the annulus between the shrouds, there will be corrosion of the aluminum with hydrogen gas as a by-product.

With a buildup of pressure due to the hydrogen gas, the inner shroud will bulge and reduce the inside area of the storage cell.

The possibility of deterioration of the boral in the spent fuel racks due to the water pressure was examined and evaluated in NUREG-0517 Supp. #4.

The evaluation states "This small amount of deterioration would have no effect on neutron shielding, alternation of properties or criticality safety.

The hydrogen produced by the corrosion of the aluminum will be released by venting to minimize bulging."

Venting by piercing a hole at the top of the cell will relieve the pressure and may allow the inner shroud to return to some position closer to the original.

The tools are designed to vent cells with or without a fuel assembly.

If a fuel assembly is located in the cell, the venting process will cause no damage to the fuel assembly.

The hydrogen, produced by the corrosion of aluminum is radiologically stable since tritium production in stagnated water is extremely low (not detectable).

No plant process or discharge is affected by this design change.

No unreviewe,d safety or environmental questions are involved.

Design Change Request

[

PSE&G SALEM GENERATING STATION SAFETY RELATED WORK ORDER LOG SALEM UNIT 2 WO NO DEPT UNIT EQUIPMENT IDENTIFICATION

'8510080593 SMD 2

23 SJ23 FAILURE DESCRIPTION:

VALVE HAS A BODY TO BONNET AND A PACKING LEAK.

CORRECTIVE ACTION:

TIGHTENED PACKING 1 1/2 TURN ON PACKING NUTS LEAK STOPPED.

8510090670 SMD 2

22MS178 CHECK VALVE FAILURE DESCRIPTION:

22MS178 DOWNSTFEAM OF 22MS6 HAS A CAP LEAK.

IT IS BLOWING STEAM.

L

' CORRECTIVE ACTION:

REPLACED GASKET & INSTALLED SHEET COMPOUND.

l I-8510170215 SMD 2

2A DIESEL GENERATOR FAILURE DESCRIPTION:

2A DIESEL HAS AN EXHAUST LEAD IN THE AREA OF 3 & 4 LEFT CYLINDER.

l l.

CORRECTIVE ACTION:

REPLACED EXHAUST MANIFOLD GASKETS ON' CYLINDERS 1,

2, & 3 LEFT.

8510170231 SMD 2

2C DIESEL GENERATOR FAILURE DESCRIPTION:

OIL LEAK AT 2C DIESEL GENERATOR PRE LUBE PUMP.

CORRECTIVE ACTION:

CHANGED OUT PRE LUBE PUMP 40.4079.

L

SALEM UNIT 2

~

WO NO DEPT UNIT EQUIPMENT IDENTIFICATION 8510270058 SMD 2

23 AUX FEED PUMP FAILURE DESCRIPTION:

SHROUD OVER COUPLING BETWEEN PUMP AND TURBINE TORN AND BENT.

CORRECTIVE ACTION:

REPAIRED AND REPLACED COUPLING SHROUD.

C_

SALEM GENERATING STATION MONTHLY OPERATING

SUMMARY

- UNIT NO. 2 NOVEMBER 1985 SALEM UNIT NO. 2 The Unit operated at full power for the entire period.

a w._

REFUELING INFORMATION DOCKET NO.:

50-311 COMPLETED BY:

J.

Ronafalvy UNIT NAME:

Salem 2 DATE:

December 10, 1985 TELEPHONE:

609/935-6000 EXTENSION:

4455 Month November 1985 1.

Refueling information has changed. from last month:

YES NO X

2.

Scheduled date for next refueling:

September 20, 1986 3.

Scheduled date for restart following refueling: November 19, 1986 4.

A) will Technical Specification changes or other license amendments be required?

YES NO Not determined to date B)

Has the reload fuel design been reviewed by the Station Operating Review Committee?

YES NO X

If no, when is it scheduled?

August 1986 5.

Scheduled date (s) ' for submitting proposed licensing action:

~

August 1986 if required 6.

Important licensing considerations associated with refueling:

NONE 7.

Number of Fuel Assemblies:

A)

Incore 193 B)

In Spent Fuel Storage 140 8.

Present licensed spent fuel storage capacity:

1170 Future spent fuel storage capacity:

1170 1

9.

' Date of last refueling that can be discharged tofspent' fuel pool assuming the'present-

' licensed capacity:

March 2003 8-1-7.R4 d

~

~O PSEG Public Service Electric and Gas Company P.O. Box E Hancocks Bridge, New Jersey 08038 Salem Generating Station December 10, 1985 Director, Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555

Dear Sir:

MONTHLY OPERATING REPORT SALEM NO. 2 DOCKET NO. 50-311 In compliance with Section 6.9, Reporting Requirements for the Salem Technical Specification, 10 copies of the following monthly operating reports for the month of November 1985 are being sent to you.

Average Daily Unit Power Level Operating Data Report Unit Shutdowns and Power Reductions Major Plant Modification Safety'Related Work Orders Operating Summary Refueling Information Sincerely yours,

U i

J. M.

Zupko, Jr.

General Manager - Salem Operations JR:kcb cc:

Dr. Thomas E. Murley Regional Administrator USNRC Region I 631 Park Avenue

{

King of Prussia, PA 19406 Director, Office of Management Information and Program Control U.S. Nuclear Regulatory Commission Washington, DC 20555 Enclosures 8-1-7.R4 7E 14 The Energy People g

I