Text
.
DEC 0 61985 Docket No. 50-219 MEMORANDUM FOR: John A. Zwolinski, Director BWR Project Directorate #1, DBL FROM:
Jack N. Donohew, Jr., Project Manager BWR Project Directorate #1, DBL SUBJECTt MEETING WITH GPU NUCLEAR CORPORATION (GPUN) ON OYSTER CREEK NUCLEAR GENERATING STATION Date & Time:
Friday December 13, 1985 9:30 a.m. - 12:30 p.m.
Location:
Room 6507 Maryland National Bank Building 7735 Old Georgetown Road Bethesda, Maryland
Purpose:
To discuss the licensee's requested deferment of feedwater nozzle inspections from Cycle 11 Refueling outage to Cycle 12 Refueling outage.
Participants:
NRC GPUNC J. Donohew M. Laggart W. Hazelton S. Leshnoff R. DeMuth MPR Associates alsmed W
)e 4
Jack N. Dono t,Jr., Project. Manager
(
BWR Project Directorate #1, DBL cc: See next page b
DBL:PD#1 o
- tm JZwolinski 85 p /<1/85 koj21 036o 851206 G
DOCK 05000219 PDR
t-UNITED STATES 8
NUCLEAR REGULATORY COMMISSION h
WASHINGTON, D. C. 20555 7
DEC 0 61985 Docket No. 50-219 MEMORANDUM FOR: John A. Zwolinski, Director BWR Project Directorate #1, DBL FROM:
Jack N. Donohew, Jr., Project Manager BWR Project Directorate #1, DBL
SUBJECT:
MEETING WITH GPU NUCLEAR CORPORATION (GPUN) ON OYSTER CREEK NUCLEAR GENERATING STATION Date & Time:
Friday December 13, 1985 9:30 a.m. - 12:30 p.m.
Location:
Room 6507 Maryland National Bank Building 7735 Old Georgetown Road Bethesda, Maryland
Purpose:
To discuss the licensee's requested deferment of feedwater nozzle inspections from Cycle 11 Refueling outage to Cycle 12 Refueling outage.
Participants:
NRC GPUNC J. Donohew M. Laggart W. Hazelton S. Leshnoff R. DeMuth MPR Associates h
M (,,,h k
\\
lf Jack N. Donohew, Jr Project Manager BWR Project Director
- e #1, DBL
\\
cc: See next page
e 6
CC:
G. F. Trowbridge, Esquire Resident Inspector Shaw, Pittman, Potts and Trowbridge c/o U.S. NRC 1800 M Street, N.W.
Post Office Box 445 Washington, D.C.
20036 Forked River, New Jersey 08731 J.B. Liberman, Esquire Commissioner Bishop, Liberman, Cook, et al.
New Jersey Department of Energy 1155 Avenue of the Americas 101 Commerce Street New York, New York 10036 Newark, New Jersey 07102 i
Eugene Fisher, Assistant Director Regional Administrator, Region I Division of Environmental Quality U.S. Nuclear Regulatory Commission Department of Environmental 631 Park Avenue Protection King of Prussia, Pennsylvania 19406 380 Scotch Road Trenton, New Jersey 08628 BWR Licensing Manager GPU Nuclear 100 Interpace Parkway Parsippany, New Jersey 07054 Deputy Attorney General State of New Jersey Department of Law and Public Safety 36 West State Street - CN 112 Trenton, New Jersey 08625 Mayor Lacey Township 818 West Lacey Road Forked River, New Jersey 08731 D. G. Holland Licensing Manager Oyster Creek Nuclear Generating Station Post Office Box 388 Forked River, New Jersey 08731 i
Mr. P. B. Fiedler Vice President and Director Oyster Creek Nuclear Generating Station Post Office Box 288
)
Forked River, New Jersey 08731 i
e
DISTRIBUTION IM5N3 NRC PDR Local PDR-NSIC BWD#1 Reading ORAS
'CJamerson
'JDonohew OELD ELJordan BGrimes HDenton ACRS (10).
OPA MSchaaf-NRC Participants-Receptionist cc list
}
,