ML20138C535

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-445/85-10 & 50-446/85-10 on 850605-07.No Violations or Deviations Noted
ML20138C535
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 10/11/1985
From: Denise R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Counsil W
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
Shared Package
ML20138C539 List:
References
NUDOCS 8510220455
Download: ML20138C535 (2)


See also: IR 05000445/1985010

Text

'

.

OCT 11 BBS

In Reply Refer To:

Dockets: 50-445/85-10

50-446/85-10

Texas Utilities Generating Company

ATTN: Mr. W. G. Counsil

Executive Vice President

400 North Olive, L.B. 81

Dallas, Texas 75201

Gentlemen:

This refers to the inspection conducted by Mr. Nemen M. Terc of this office

during the period June 5-7, 1985, of activities authorized by NRC Construction

Permits CPPR-126 and CPPR-127 for Comanche Peak Steam Electric Station, Units 1

and 2, and to the discussion of our findings with Mr. R. A. Jones and other

members of your staff at the conclusion of the inspection.

Areas examined during the inspection were limited to follow up of items

identified during the emergency preparedness appraisal. Within these areas,

the inspection consisted of selective tours of emergency facilities, examination

of procedures and representative records, interviews with personnel, and

observations by the inspector. The findings are documented in the enclosed

inspection report.

Within the scope of the inspection, no violations er deviations were

identified.

Should you have any further questions concerning this inspection, we will be

pleased to discuss them with you.

Sincerely,

."CIUNJ SN L,,"

R. P. Denise, Director

Division of Reactor Safety

and Projects

Enclosure:

Appendix - NRC Inspection Report

50-445/85-10

50-446/85-10

cc w/ enclosure:

1 rc:

,de

]t /'l /85

,,, a(see page 21h( g

JBBaird

e

R Aa 1 ' RPDenise

C X A e ~RR

TJe tennanVNoonan

7 / 9 /85 f /pl/ 5 y /yG/85 y/q/85 p/7/85

'

8510220455 051011 -

PDR ADOCK 05000445

'fl

.,

.

-Texas Utilities Electric Company -2-

cc w/ enclosure:

Texas Utilities Electric Company

ATTN: J. W. Beck, Manager,

Licensing

Skyway Tower

400 North Olive Street

Lock Box 81

Dallas, Texas 75201

Texas Radiation Control Program Director

bec to DMB (IE35) l

bec distrib. by RIV:

  • RPB * MIS System
  • RRI-OPS *RSTS Operator
  • RRI-CONST. *EP&SPS
  • Section Chief (RPS/C) R. Denise, D/DRSP

V. Noonan, NRR R. Martin, RA

S. Treby, ELD- Juanita Ellis, Pres.- CASE

  • RIV File Renea Hicks, A/ Atty General, EP Div.-TX

R. Bangart *D. Weiss, LFMB (AR-2015) '-

  • J. Baird *N. Terc *w/766

T. Westerman

i

.

t

l-

L.