_ _ _ _ _ _ - _

.t OPERATING DATA REPORT DOCKET NO.

50-298 DATE 10 8-85 CONIPLETED BY 3.K. S-lisburv TELEPl!ONE (402) 825 Mil OPERATING STATUS Notes

1. Unit Name:

ennno-w c t.,,,. s,, r ; ~,

2. Reporting Period:

9anec-hor-1985

3. Licensed Thermal Power (MWt):

2381 836

4. Nameplate Rating (Gross S!We):

778

5. Design Electrical Rating (Net 5tWe):

207

6. Af asimum Dependable Capacity (Gross $1We):

764

7. Staximum Dependable Capacity (Net S!We):
8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report.Gise Reasons:
9. Power Lesel To which Restricted.lf Any (Net S!We):
10. Reasons For Restrictions,If Any:

This Stonth Yr..to Date Cumulatise II. liours In Reporting Period 720.0 6.551.0 98,640.0

12. Number Of flours Reactor Was Critical 720.0 987.3 73,942.9
13. Reactor Reserve Shutdown !!ours 0.0 0.0 0.0
14. Hours Generator On-Line 720.0 860.2 7?.68a.8
15. Unit Reserve Shutdown flours 0.0 0.0 0.0
16. Gross Thermal Energy Generated (SIWil) 1,015,680.0 1,152,384.0 14 2. 5 9 2,19 5. t,
17. Gross Electrical Energy Generated (MWil) 3 2 0, 6 4 H,,0,,,,,,,

pg,911.o 45,374,407,o j

18. Net Electrical Energy Generated (31Wil) 107,228.0 3,i., 7 : 9. c r.3,721,337,9
19. Unit Senice Factor 300.0 13.I 73.7
20. Unit Availability Factor 100.0 13.I 73.7
21. Unit Capacity Factor (Using SIDC Net) 55.9 67 sg o
22. Unit Capacity Factor IUsing DER Net) 54.8 6.6 57.0
23. Unit Forced Outage Rate

".0 0.0 3.6

' 24. Shutdowns Scheduled Oser Next 6 Stonths IType. Date,and Duration of Each t:

25. If Shut Down At End Of Report Period. Estimated Date of Startup:
26. Units in Test Status ! Prior to Commercial Operationi:

Forecast Achiesed INITIA L CRIIICALITY INITIAL ELECTRICITY CO\\1\\lERCIAL OPER ATION g.

0512120497 850930 h

g PDR ADOCK 05000298 al PDR H

po;7

I e

1 AVERAGE DAILY UNIT POWER LEVEL DOC!'ET No, so M98

~

UNIT m DATE 10 8-85 t

1 C0\\lPLETED !!Y J.K. Sclisbury TELEP110NE (402) 825.1811 l

~

1

.\\f0 NTH September, 1985 I*

DAY AVERAGE DAILY POWER LEVEL DAY AVER AGE DAILY POWER LEVEL i

j 65the Net t 1.\\lhe Neti l

223 37 490 2

223

,3

$37

__.339._____

y

., g 3 4

'M 20 359 5

337 gg cos 6

497 444 7

'70

... 3...

.. <a p l

S 471

?

34 394 9

540 25 497 10 ut 26

'. 81 l

11 504 539 1

12 335 535 13 373 49 gg 14 4 >6 30 568 15

'07 3,

16 411

!NST!!UCT'ONS On this farmat.!ist t'.

ser2;c daily unit power toelin SIWE Net fi>r each d2) :n the reportin: month. Compute to I e nearett whole.eputt.

plJ"* )

~

UNITSIIU1 DOWNS AND POWER REDUCTIONS DOCKET NO.

50-798

^

UNIT N AME N

DA1E in R 95 COMPLETED NY v

r-c,7 _i _.

REPORT MONill ceMemho - 1985 1ELEPHONE (402) 82%3aii-3

=-

es 3 u.

5" 54 l.'"5

c.

Cause A Centrective E :*

E 7

N"-

DJ'c h

3$

d'

.2 s 5 Esent u '2 El Atei,m to jU c3 E 5

jdi Report =

E0 Prevent Recurrence 6.

(NONE DURING THIS REPORT :NG PERIOD)

I 2

8 3

4 T: Earted Reasork Method:

Emlubie G Instructitms 5: Sshedu!ed A-Equipment Failure (Enplain)

I Manual for. Preparation of Data j

Bataintenance of Test 2 Manual Scram.

Enery Sheets for Licen:ce C-Refueling 3 Automatic Scram.

Event Report (LLR) file (NURI.G-t D-Regstatory Restriction 4-Other (Emplain) 01611 00perator Training & License Esaminatism

[

F-Admmistrative 5

G-Operational Error (Enplain)

Eshibit I Same Source 08/77)

II Other (Explain)

I

OPERATIONS NARRATIVE COOPER NUCLEAR STATION September, 1965 The plant operated through the month cf Septenber with no scheduled or un-scheduled shutdowns and no unscheduled power reductiens.

Str.rt-up testing con-tinued through the month of September.

Nebraska Public Power District

""' ""* E""#2!%M ER""T" ""'

COOPE H NUCLE AR S t A floN

=wm:i==a 2

=: _ _

CNSS850588 October 8, 1985 Director, Office of Managenent Information and Program Control U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Subject:

Menthly Operation Status Report for September 1985 Docket No. 50-298 Gr:ntlecen:

Enclosed for your infernation and use for Septer.ber 1985.is the Cooper Nuclear Station Monthly Operating Status Report The report incluaes Operating Status, Average Daily Unit Power Level. Unit Shutdown Data, and n Narrative Sunnary of Operating Fxperience.

Should you have any entnents or reqaire report, please contact additional infornation regarding this te.

Sincerely,

/) / 0

.ry,L. JL w wen.,

P. V. Thomasor Division Manager of Nuclear Operations PVT:lb Enclosure G. D. Watson w/ enc.

cc:

A. C. Gehr w/cnc.

R. D. Martin w/ enc.

t l