T

~'

V e

e y

j

( * ' * ' ' ' Apri1} 24,1997 Mr. G. A. Kuehn, Jr.

! t Program Director SNEC Facility GPU Nuclear, Inc.

2574 Interstate Drive

!Harrisburg, PA 17110

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION (TAC N0. M97155)

Dear Mr. Kuehn:

We are continuing our review of your amendment request for Amended Facility License No. DPR-4 for the GPU Nuclear, Inc., and Saxton Nuclear Experimental Corporation, Saxton Nuclear Experimental Facility. During our review of your amendment request, questions have arisen for which we require additional information and clarification.

Please provide responses to the enclosed request for additional information within 30 days of the date of this letter.

-In accordance with 10 CFR:50.30(b), your response must be executed in a signed original under oath or affirmation.. Following receipt of the additional information, we will continue our evaluation of your amendment request. This is a partial initial request for additional information.

Sections 3.6.2 and 3.6.3 of-your-proposed technical specifications are still under initial review and additional questions may be forthcoming.

If you have any questions regarding this review, please contact me at.

(301) 415-1127.

Sincerely, Original signed by:

Alexander Adams, Jr., Senior Project Manager 1

Non-Power Reactors and Decommissioning Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation 4

j Docket No. 50-146

3..

,c i

Enclosure:

As stated, cc w/ enclosure:

~

~

See next page DISTRIBUT10Ni l'

[ Docket:E1'e:50(146L

=SWeissa EFord OGC PUBLIC

EHylton Region'I PDND R/F

!AAdams aTDragoun, Region I TMartin

'k

.MMendonca

,TMichaels PIsaac

-lPDoyle' WEresian g

g

-PDND:LA ",

PDND:D PDN t

AA EHylton SWeiss 4/j 97 4/pV97 4/2.V97 0FFICIAL RECORD COPY I

1 DOCUMENT NAME: G:\\SECY\\ ADAMS \\146RAI3.15 i

l j

9704290221 970424

+

PDR ADOCK 05000146' P

PDR

MN QIOQ s

3".

UNITED STATES i

NUCLEAR REGULATORY COMMISSION 8

WASHINGTON, D.C. 20555-0001 April 24, 1997 Mr. G. A. Kuehn, Jr.

Program Director SNEC Facility GPU Nuclear, Inc.

2574 Interstate Drive Harrisburg, PA 17110

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION (TAC NO. M97155)

Dear Mr. Kuehn:

We are continuing our review of your amendment request for Amended Facility License No. DPR-4 for the GPU Nuclear, Inc., and Saxton Nuclear Experimental Corporation, Saxton Nuclear Experimental Facility.

During our review of your amendment request, questions have arisen for which we require additional

-information ano clarification.

Please provide responses to the enclosed request for additional information within 30 days of the date of this letter.

In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation.

Foll: wing receipt of the additional i

information, we will continue our evaluation of your amendment request.

This is a partial initial request for additional information.

Sections 3.6.2 and 3.6.3 of your proposed technical specifications are still under initial review and additional questions may be forthcoming.

If you have any questions regarding this review, please contact me at (301) 415-1127.

Sincerely, thfb'CCe<0' C m2--

Alexander Adams, Jr., Sp'njof Project Manager Non-Power Reactors and Decommissioning Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation Docket No. 50-146

Enclosure:

As stated cc w/ enclosure:

See next page i

Saxton Nuclear Docket No. 50-146 Experimental Corporation Page 1 of 2 cc:

Mr. William P. Dornsife, Director Carbon Township Supervisors Bureau of Radiation Protection ATTN:

Penny Brode, Secretary Department of EnvironmentC Protection R. D. #1, Box 222-C

~13th Floor, Rachel Carson State Saxton, Pennsylvania 16678 Office Building P. 0. Box 8469 Hopewell Township Supervisors Harrisburg, Pennsylvania 17105-8469 ATTN:

Sally Giornesto, i

Secretary Mr. Jim Tydeman RR 1 Box 95 1402 Wall Street James Creek, Pennsylvania 16657-9512 Saxton, Pennsylvania 16678 Mr. D. Bud McIntyre, Chairman Mr. James H. Elder, Chairman Broad Top Township Supervisors i

Concerned Citizens for SNEC Safety Broad Top Municipal Building Wall Street Ext.

Defiance, Pennsylvania 16633 Saxton, Pennsylvania 16678 Mr. Don Weaver, Chairman Mr. Ernest Fuller Liberty Township Supervisors R. D. #1 R. D. #1 Six Mile Run, Pennsylvania 16679 Saxton, Pennsylvania 16678 Saxton Borough Council U.S. Army Corps of Engineers ATTN:

Peggy Whited, Secretary Baltimore District 9th and Spring Streets ATTN:

S. Snarski/P. Juhle Saxton, Pennsylvania 16678 P. O. Box 1715 Baltimore, Maryland 21203 Ms. Norma Ickes, Chair Bedford County Commissioners The Honorable Robert C. Jubelirer County Court House President Pro-Temp Senate of 203 South Juliana Street Pennsylvania Bedford, Pennsylvania 15522 30th District State Capitol Mr.. Larry Sather, Chairman Harrisburg, Pennsylvania 17120 Huntingdon County Commissioners County Court House Mr. William G. Heysek Huntingdon, Pennsylvania 16652 Licensing Department TMI Nuclear Station Saxton' Community Library P. O. Box 480 Front Street Middletown, Fennsylvania 17057 Saxton, Pennsylvania 16678 Mr. Manuel Delgado Mr. Arthur Rone 2799 Battlefield Road Vice President Nuclear Fishers Hill, Virginia 22626 Safety and Technical Services GPU Nuclear Inc.

Mr. Eric Blocher 1 Upper Pond Road 216 Logan Avenue Parsippany, New Jersey 07054 Wyomissing, Pennsylvania 19610 Ernest L. Blake, Jr., Esquire Shaw, Pittman, Potts, and Trowbridge 2300 N Street, NW Washington, DC 20037

k Saxton Nuclear Docket No. 50-146 Experimental Corporation Page 2 of 2 4

cc:

Mr. David Soloksky 30 Russell Street San Francisco, California 94109 i

- Mr. Gene Baker 501 16th Street Saxton, Pennsylvania 16678 i

Mr. Dick Spargo 1004 Main Street j

Saxton, Pennsylvania 16678 Mr. Tom Strnad TLG Services i

148 New Milford Road East i

Bridgewater, Connecticut 06752 Mr. Gareth McGrath Altoona Mirror 301 Cayuga Avenue Altoona, Pennsylvania 16603

a.. -.

ENCIDSURE REQUEST FOR ADDITIONtl INFORMATION

.SAXTON NUCLEAR EXPERIMENTAL FACILITY DOCKET NO. 50-146 1.

Please address what the expectations are regarding how management will regularly review the status and adequacy of that part of the quality assurance program (QAP) which they are executing.

The QAP plan should incorporate these expectations.

2.

The sections entitled Procedures and Drawings (4.1-4.3)-and Document Control-(7.1-7.5) both omit references to the word " instructions." Will

-instructions be used to control work activities?

If instructions are used, the QAP should be modified accordingly.

3.

The QAP Section 12.1, " Test Control," reflects the following requirements:

testing to assure satisfactory performance in service; testing performed-using test procedures written to design documents; and proof tests as appropriate.

However,-the following items were noted to be absent: procedural assurance that prerequisites were met; assurance of adequate, test instrumentation; test performance under suitable conditions; and test documentation-and evaluation.

Please discuss how the:e items are addressed for-activities'such as heavy 3

lifting, and installation and operation of radiation monitoring and air filtering systems, and modify the QAP accordingly.

4.

The section entitled Quality Assurance Records (18.1-18.7) did not address QAP requirements to generate inspection records that would identify the inspector or data recorder, the type of observation, the results, the acceptability, and' the action taken in connection with any deficiencies noted.

Please address whether these are relevant inspection. attributes and modify the QAP accordingly.

5.

Please discuss what standards will be utilized to implement'the QAP and identify them in the QAP accordingly..

.,