Text

...

l

'g UNITED STATES 8

NUCLEAR REGULATORY COMMISSION o

{

WASHINGTON, D. C. 20666 s

SOUTH CAROLINA ELECTRIC & GAS COMPANY SOUTH CAROLINA PUBLIC SERVICE AUTHORITY DOCKET NO. 50-395 VIRGIL C. SUMER NUCLEAR STATION, UNIT NO. 1 i

AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 47 License Nn. NPF-12 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment to the Virgil C. Sumer Nuclear Sta'tfon,

~ ~

Unit No. 1 (the facility) Facility Operating License No. NPF-12 filed by the South Carolina Electric & Gas Company acting for itself and South Carolina Public Service Authority (the licensees), dated October 8, 1982, and supplemented April 26, 1984, and August 2 and September 25, 1985, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Comission's regulations as set forth in 10 CFR Chapter I; U.

The facility will operate in confomity with the application, as amended, the provisions of the Act, and the regulations of the Comission; C.

There is reasonable assurance: (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations set forth in 10 CFR Chapter I; D.

The issuance of this license amendment will not be inimical to the comon defense and security or to the health and safety of the public; E.

The issuance of this license amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

)

2.

Accordingly, the license is hereby amended by page changes to the Technical l

Specifications as indicated in the attachments to this license amendment and paragraph 2.C(2) of Facility Operating License No. NPF-12 is hereby amended to read as follows:

i (2) Technical Specifications TheTechnicalSpecificationscontainedinkppe'ndixA,asrevisedthrough Amendment No.

47, are hereby incorporated into this license. South j

Carolina Electric & Gas Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

~

0512110032 851123 f

PDR ADOCK 05000395 P

PDR l

1 4

3.

This license amendment is effective as of its date of issuance.

FOR THE NUCLEAR R'lGULATORY COMMISSION I

4+

/

Elinor G. Adensam, Chief Licensing Branch No. 4 Division of Licensing Date of Issuance: November 23, 1985 G

f i

ATTACHMENT TO LICENSE AMENDMENT NO. 47 FACILITY OPERATING LICENSE NO. NPF-12 DOCKET NO. 50-395 Replace the following pages of the Appendix "A" Technical Specifications with the enclosed pages. The revised pages are identified by Amendment number and contain vertical lines indicating the areas of change.

Amended

?.o.9%

3/4 6-20a 3/4 6-20b 3/4 6-20c 9

  • +.

'T 9

.c T_ABLE 3.6-1 (Continued)

CONTAlletENT ISOLATION VALVES i

VALVE NUMBER MAXIMUM e

C.

REACTOR BUILDING PURGE SUPPLY ISOLATION TINE 5

AND EXHAUST ISOLATION FUNCTION (SEC) b 1.

0001A-AH Reactor Building Purge Supply 5

2.

00018-AH Reactor Building Purge Supply 5

3.

0002A-AH Reactor Building Purge Exhaust 5

4.

00028-AH Reactor Building Purge Exhaust 5

5.

6056-HR Alternate Reactor Building Purge Supply Line 5

6.

6057-HR Alternate Reactor Building Purge Supply Line 5

7.

6066-HR Alternate Reactor Building Purge Exhaust Line 5

8.

6067-HR Alternate Reactor Building Purge Exhaust Line 5

D.

MANUAL (I) w 1.

8767-DN Demineralized Water Line.

N/A 1

2.

8768-DN Demineralized Water Line N/A 3.

6772-FS Fire Service Hose Reel Supply N/A e4 4.

6773-FS Fire Service Hose Reel Supply N/A F

5.

2679-IA Breathing Air Supply Line N/A 6.

2680-IA Breathing Air Supply Line N/A 7.

6587-NG Nitrogen Supply To Steam Generators N/A 8.

2912-SA Reactor Building Service Air N/A 9.

6671-SF Refueling Cavity Drain Line N/A

10. 6672-SF Refueling Cavity Drain Line N/A
11. 669 PSF Refueling Cavity Fill Line N/A
12. 6698-SF Refueling Cavity Fill Line N/A
13. 7135-WL Reactnr Coolant Drain Tank Discharge To Waste N/A E.

REMOTE MANUAL (2) k 1.

%02-CC Component Cooling To R. C. Pumps N/A

?,

2.

8102A-CS#

Seal Injection To Reactor Coolant Pump A N/A 3.

8102B-CS#

Seal Injection To Reactor Coolant Pump B N/A 2

P 4.

8102C-CS#

Seal Injection To Reactor Coolant Pump C N/A O

I t

TABLE 3.6-1 (Continued)

CONTAINMENT ISOLATION VALVES E

MAXIMUM VALVE NUDGER ISOLATION TIME e$

E.

REMDTE MANUAL (Continued)

FUNCTION (SEC)

[

5.

8107-CS Charging Line To Regenerative Heat Exchange N/A 6.

60508-HR Hydrogen Analyzer Return Line N/A 7.

6051A-HR Hydrogen Analyzer Supply Line N/A 8.

6051B-HR Hydrogen Analyzer Supply Line N/A 9.

6051C-HR Hydrogen Analyzer Supply Line N/A 10, 6052A-HR Hydrogen Analyzer. Return Line N/A

11. 60528-HR Hydrogen Analyzer Return Line N/A
12. 6053A-HR Hydrogen Analyzer Supply Line N/A
13. 60538-HR Hydrogen Analyzer Supply Line N/A
14. 8701A-RHf RHR Pump Suction From Reactor Coolant Loop A N/A
15. 87018-RHf RHR Pump Suction From Reactor Coolant Loop C N/A R
16. 8801A-SI Boran Injection Tank To Reactor Coolant Loops N/A
17. 8801B-SI Boran Injection Tank To Reactor Coolant Loops N/A T

18.

8811A-SI RHR Pump A Suction From Recirculation Sump N/A g

19. 88118-SI RHR Pump B Suction From Recirculation Sump N/A cr
20. 8884-51 High Head Safety Injection To Reactor Coolant Loops N/A
21. 8885-SI High Head Safety Injection To Reactor Coolant Loops N/A
22. 8886-SI High Head Safety Injection To Reactor Coolant Loops N/A
23. 8888A-SI

-Low Head Safety Injection To Reactor Coolant Loops N/A

24. 88888-SI Low Head Safety Injection To Reactor Coolant Loops N/A'
25. 8889-SI Low Head Safety Injection To Reactor Coolant Loops N/A
26. 3003A-SP Supply To Reactor Building Spray Nozzles N/A
27. 30038-SP Supply To Reactor Building Spray Nozzles N/A
28. 3004A-SP Spray Pump A Suction From Recirculation Sump N/A

(

29. 30048-SP Spray Pump B Suction From Recirculation Sump N/A

=

30.

3103A-SW Service Water From Reactor Building Cooling Unit A N/A I

31. 31038-SW Service Water From Reactor Building Cooling Unit B N/A g
32. 3106A-SW Service Water To Reactor Building Cooling Unit A N/A
33. 31068-SW Service Water To Reactor Building Cooling Unit B N/A

.o 34.

3110A-SW Service Water To Reactor Building Cooling Unit A~

N/A 35.

31108-SW Service Water To Reactor Building Cooling Unit B N/A

,.7

TABLE 3.6-1 (Continued) h CONTAINMENT ISOLATION VALVES E

i MAXIMUM c-VALVE NUMBER ISOLATION TIME

[]

F.

CHECK FUNCTION (SEC) sa 1.

7541-AC CRDM Coolant Water Inlet Line N/A 2.

7544-AC CRDM Coolant Water Outlet Line N/A 3.

9570-CC Component Cooling To R. C. Pump Bearings N/A 4.

9689-CC Component Cooling From R. C. Pump Bearings N/A 5.

8103-CS Reactor Coolant Pump Seal Water Return N/A 6.

8368A-CS#

Seal Injection To R. C. Pump A N/A 7.

83688-CS#

Seal Injection To R. C. Pump B N/A 8.

8368C-CS#

Seal Injection To R. C. Pump C N/A 9.

8381-CS Charging Line To Regenerative Heat Exchanger N/A 10, 6799-FS Fire Service Deluge To Charcoal Filters N/A

11. 2661-IA Instrument Air Supply To Reactor Building N/A Ri
12. 6588-NG Nitrogen Supply To Steam Generators N/A
13. 8046-RC Pressurizer Relief Tank Makeup Water Line N/A 3'

14.

2913-SA Service Air Supply To Reactor Building N/A E!

15. 3009A-SP Supply To Reactor Building Spray Nozzles N/A
16. 30098-SP Supply To Reactor Building Spray Nozzles N/A
17. 8947-SI Accuelator Nitrogen Supply N/A 18.

8661-SI Fill Line To Accumulators N/A

  1. alve not subject to Type "C" leakage test.

V (1) Manual valves may be opened on an intermittent basis under administrative control.

(2) Remote manual valve positions are maintained by administrative control.

k (3) The provisions of Specification 3.0.4 are not applicable from December 28, 1982, until July 1, 1983.