ML20137X721

From kanterella
Jump to navigation Jump to search
NPDES Discharge Monitoring Rept for Oct 1985
ML20137X721
Person / Time
Site: Salem  
Issue date: 10/31/1985
From:
Public Service Enterprise Group
To:
Shared Package
ML20137X641 List:
References
NUDOCS 8512100610
Download: ML20137X721 (18)


Text

.

4

. ADORESS (Ier8Md8 PERMITTRE NAM N ATIoNAL eoLLUTI.NT ot9CH' RGE f.:LIMINATloN CVSTEM tief)fis pg,pg,, Jg persasey Neme/imes si dafrecer)

DISCHARGE MONITORING REPORT ttstris

% an.tg_.e.SSis._Q ~. W W _ _ - _ _ _

o.gg,,lNe,,f33.geg7J h

<2***

t-':I i.Aggaggy _PSE&G N J 0 0 A / 2 I

481 GP AT MI k',_.'._P.AQA. M.57.0 E _ _ _ _ _ _ _ _ _ _ _

re=M'T NuMara a'=cwAaor NuMara I7 7 I

._NDDWK

_ _- MI._.07101. _ _ _ _ _ __

you,ron,uo pcn,oo DELAWARE RIVER

. F.Maur_SE El_ N.__.

G W. ST_AT. EN._ ___._ __ _ _ _

vrA=

MO

' F

-~

7eh

= 1 SAL

,' w;.afto.M_IDWER ALICHAYS CREEK raoM 85' 10 01 m

85 10 131 COOLING WATER e

rie si, r22 ss

<24 ii sie 7s

<2s >*>

( * 's#

NOTE: Read instructions before completing thie form.

(9 8 ardf 8*47 ouANTITv OR LOADING fd I erd f 8*47 ouALITY 04 CoNCrNTRATION PAftAMETER

  1. de 9 57 (94 elf (E8 d*J tes 181 (td-s t)

S^

E A,. a AvrRAGE M A RIMuM UNITS MINIMUM AVERAGE M A xiMuM UNITS (62-4.7/

fed ets M79) 0001G Z

TEMPERATURE, WATER

"<I u""E"'t"7 15.30 19.20 23.20 CONT NA DEG. CENTIGRADE DEG.C INFLUENT

  • *ou'a* "' "

CONT

^

L UUULU TEPPERATURE, WATER "ellu"=7EeNT 18.50 25.10 34.80 0

CONT NA DEG. CENTIGRADE DEG.C EFFLUENT GROSS atEEr" 46.00 CONT UCUlb

't TEMPERATURE Mel u"a?Inw 0.00 5.90 14.70 0

CONT NA OIFFERENCE DEG C EFFLUENT NET atoutRE MENT 15.30 UU400 L

PH Mel u"n?Erw 7.40 7.70 8.00 0

2/7 GR SU

~

EFFLUENT GROSS aroEE**

6.00 9.00

?/7' GR 00400 2

u"a?Iew 7.20 7.75 8.30 2/7 GR PH "eA SU pr.MiT INFLUENT arovia Mrw 2/7 GR 500%

1 FLOW

"<AsuarMcNT 0.00 310.10 532.80 CALC NA MGD er n,,,

EFFLUENT GROSS acoumcMe" CONT

  • > C G r> 4 I

1/30 sA a' CHLO'7INE, FREE

"'^su"nc'Mcw

<o.01 0.01 0.04 0

RCSILUtl

'3 KG/n w qqft e

EFFLUFNT G'10SS ar ou* '"**

0.20 0.50 CONT ys,og,MgNT, is,gi,c,Nro,,=,,i,m,a,r,googfig,T n,Now.

N:MrmToc en Nei At e ecuTive orrice=

TeorewoNe oATr c

c

/ A J. Trejo sureO=TiNo oocuMc NT. on iNTrNTiON Atty TAMeenNo WITH ANY MONITORING DE VICE OR METHOD ARE C RI M,IN A L d4ATue.c or ese NCi

. executiva r,.*

609 339-18399 85 11 22 lbd. Prot./ Chem. Manager or r r ".5 '.5-55E 'e o s C. e iOOi ANo as u s C. e i s i e.

as..

s, z.f a.r......-. -.,. e s, so.,.,.c a. sie.ooo

..si.,..,s...

as.. s, r.

orricen oa AuTwO=irro AceNT

=

TveroO.r.,mro NuMera vrAn Mo oAv COMMENT (.ND E EPL AN ATION Or ANY veOL ATeoNS (Refmere.N arrerhaenere A.erf

~

DIS API IS #11. CONDENSER COOLING WATER.

NOT MORE TIIAN 3 CONDEUS MAY. DIS. TOTAL OR FREE CL AT ANY TIME,,

AND NOT.MORE TilAN 30 MIN. EACll TIME.

8512100610 851122 PDR ADOCK 05000272 R

PDR E Ps4 Frwrvg 117().1 f Rev if).77) PREVIOUS EDtTION TO BE u%rD tRrPLACE S E PA rORM T-40 WHICH M Ay NOT BE use u e

PAGE, OF,,

PERMITTEE NAME/ADDREgg (forissde C ATION1L POLLUTA.7 DISCH ARGE ELIMIN ; TION SYSTEM (NPDU)

Form Approved ferstwp Home/Loretion U dlSerem*>

DiSCH ARGE MONiTOREN 3 REPORT (DnC)

GM ) N:.138 - R0073 BhM_K _ S

  • O_* :_ Yb-.--_---------

II*'*>

(#%

PSE&G NJ0005622 481 GP. AT MI

_A D D_R_E_se pes "If N UM e a of.c.em E Nu-.r.

17 7 1

EAR.A._BOR 570 __.10c

_M MI.

A7.lOl.--------

uOnirORino pgRIOo rKatn._M Gyt'E._R_A_M,_S'IAT_IpN 85 10 01 M

M m

Prom yo O')OLING WA'IER LOC _AT_ tow O__'ER_Jt_LT1_34_AY_S _CR_EE_K ____ _ _ _ _--

YEAR MO DAY YEAR MO _

DAY Unn> In-n a247IT 96 n> um n> oa e,)

NOTE: Reed IRetrucibne before Completing thle form.

[\\

(J qJerd Omf,)

oU ANTITY OR LOADING (4 Card Unir) oU ALITY OR CONCENTR ATION rm Eo,u tsect g gg ptg PAR AM ETE R (44-$J)

(3441)

. (JM 3)

(46JJ)

(3441)

NO.

A E3 TYPE ANaLyste

' JJ2 4.%

AVERAGE M ARBM UM U NITS MINIMUM AVERAGE M ARIM UM UNITS

.(g

[624D (644#) -

(19.70)

=

  • *
  • i 00530 1

M E A.A M PLE 40.00 40.00 gg g g

1/30 GR Ua EM EMT SU5PmTr.0 PERMIT 1/30 GR REoUiR EM Ewr mm mg 00530 B

  • AMPtE 63.00 63.00 1/30 GR M EA S U REM ENT SOLIDS,. 'IDIAL

!C/L a

SUSPENDED PERMtv R6Cuit EMEur 1/30 GR S'ITEAM INTME 00530 4

SAM O 0.00r 0.00

+0 MEASURE =mMT 1/30 GR SOLIDS, 'IDIAL IC/L SUSPENDED PERMIT

,, e*

g REoUiM EM Ellv 30.00, 100.00 1/30' GR' 00556 1

. A M PtE m,

, p,,

<5.00

""^*""*"ENT 1/30 GR OIL AND GREASE m/L PERMir -

1./30' GR EE'FLUWF GBOSS REoUiREMEur

_~

s 00556 B

g.,,,

1/30

-GR OIL AND GREASE ME^suREME"'

<5.00 N ME PERM?

1l30 GR REoulRnMENT.

t s AM PLE OIL AND GREASE MEASUREMENT 0.00 1/30, GR eERMits

    • oe 10.00 EFFLUENT NET REcuiREMENT.

1/30 GR S A M PL E M E A S U R EM ENT e

PERMIf R EQUIR EM E*dT N AM7/ TITLE PRINCIPAL EXECUTIVE OFFICER THis DOCUMENT 19 SIGNED WITH RFCOGNITION THAT MNOW.

TELEPHONE DATE INGLV M ANING A F ALSE CERT 4FIC ATION CA TN*A REPORT OR j

J.,ITCJO s u PPOR TING DOC u M E NTo:

,4 IN T E N T ION A LL7 TAMPERING WITH ANY MONITORING DEVICE OR M ET HOD ARE CRIMINAL 85 11 22 og9T OFFENSE 9. SE E IS U.S C. % 1000 AN D 3 3 U R.C. $13 9 9.

I f*cani.

glGN AT E OF PRINCIPAL ELJTavE 609 339 4399 g'~ ]* gg *!g@

  • A teos under the ne santures may be funre uP to Slo.noa nedfor nueesimum

^

A TYPED OR PRINTED deprisonment of herarere 6 months and 31rers.)

OFFICER OR AUTHORIZED AGENT NUMBER YEAR MO DAY c

g COMM ENT 6.ND EX PL AN ATION OF ANY WlOLATIONS (Referrare efj erfarkmcate here) rPA Ftwm 33:>01 (RRv 10 77) PREVIOUS EDITION TO BE USED IREPLACES EPA FORM T=40 WHICH M AY NOT BE USED.)

PAGE OF

PameerTTre psaasE/ADOIDESS W NiTIONAL POLLUTINT otSCH1RGE ELIMINATION CYSTEM f%P(MS)

FenoA p M raramir

,f s.,wa yder,

DISCHARGE MONITORING REPORT grisers OMJ h 138- @ J

-GCN MGR D X-ATT

~ ~ ~-~

es ses err-ra

([gueNW

_ b -.

_ -. _ _ _ -. -_. _ j NJ00CS622 I

482 GP AT MI' inc rE =M T NuM.ER o..CuA NuM.

17 7 I

, ---44=F s70 o r i or------

,c";,,, mINr GENERATING'ETKTION---~~-~~

DELAWARE RIVER

,EA.

O oA O i oA, gcGTNTirTUDUY5 tifEIR-----------

rROM 85 10 01 TO 85 10 j31-'

COOL ING WATER

.(-------_----.------------------------

(If ordff*hJ QuANTIT, OR LOAOfNG (dis'di>*%J QUALITY OR CONCENTRATION F"E 7 Y SA40PLE PARAa8ETER Id8 9 '#

fid 8IJ

(" d'l ga, g,,

gga.4pp NO.

ANa've's t u. or, AVERAGE M A EtMUM UNITS MfMIMUM AvfRAGE M A RIMUM UNITS

  1. 62 4J1 fed-e,J fe9 7ep 00010 2

CONT NA TEMPFRATURE, WATER

"'**u"*" "

15.30 19.20 23.20 DEG. CENTIGRADE o

OEG.C

~-

INFLUENT CONT u"n?Mm 18.80 26.10 32.90 0

CONT NA T

RATURE, WATER mea DEG.C t '

DEG.CENTIGRADF

=

EFFLUENT GROSS 46.00 CONT OOO16 4

TEMPERATURE usAsuarM w 0.40 6.90 13.60 0

CALC NA DEG C i

DIFFERENCE c

EFFLUENT NET Ra ou'"'""

15.30 Mellu"a7ErNT 2/7 GR SU EFFLUENT GROSS "ro' '

w 6.00 9.00 2/7 GR 00400 2

,,,,,t,

2/7 GR PH McAsuaEMeNT pen,,

SU INFLUENT

    • ou'" E ""

2/7 GR u"a7JsNT 0.00 302.20 532.80 CALC NA F CW "aA

' MGD Re RM,,

EFFLUENT GROSS RaouiRaMe"7 CONT SCC 64 1

1/30

        • Y"Y""

<0.01 0.01 0.04 0

NA CHLORINE, FREE" g

RESIDUSL

 ? 3 KG/DSY MG/L EFFLUENT GROSS REQU;REMENT 0.20 0.50 CONT NIME/ TITLE PRsNC6 PAL EXECUT1vE OFFICER H.

uM NT ts.IONED W TH RE ONITI N THAT 8t NOw.

TELEPHONif DATE

/M g1.. TrejO suerOafiNo oOCuMENis OR eNT ENTiON ALLv Ta MPE nimo 509

'339-4399 85 11 22

,,s...

ARE CRIM Ilad. Prot./ Chem. Manager O,.rr E N$,,E s. sE r '.a..,u.s C..o E vlC,.E WITH ANY h80 N I T O RI N G OR METHOD

..,i,e.i s,, e,IN A,L,,,,,,,go,,,,,,C,ALunduTive r,

3.o0, ANo n u C.

TYPED OR PRINTED daved=****' af A*'**** 8 ***'h' *ad 9,eers A OFFICER OR AUTHORIZED AGENT

{D NUM.ER YEAR MO DAY COMMENT AND EIPLANATION Or ANY vtOLATIONS (Arefere.r, eJr e,,ere e.,e her,J DISC 482 IS #12 COND COOLING WATER.

M MORE THAN 3 COND MAY DIS TOTAL OR FREE,CL AT ANY TIME, AND NOT MODF TFAN 30 MI W'PM FACH 'T'I ME. No Sans.1 were cbtained due to entrainment study sample equipent configuration ~.'

~

ma rnrm wn-1 enev in.7n raEviOus EotT*0N TO eE usEo inErtACEs E P A rOnM T.AO wwiCw M Av NOT st usro PAGE 3 OF } g

PERestTTEE NAM 7/ADORESS (I*"'8Mit C' ATIONZ L POLLUTANT Ot9CHIRGE CLIMINLTION CYSTEM (NPDU)

ForRe AM paresser nonMitsemsa et dramael DI!CH ARGE MONITORIN3 REPORT (DAG)

OM) N;.138. R007.7

'.go_nq,M O_ ""E N___________

I (1 *

(8T-8D neu.tg a, PSE&G NJ0005622 482 GP,AT MI s.

inc PEIMir MUM.ca o..C E. au :.

17 7 1

t _ _ _- M a M 570

(

M _ _ _ _ MI.-.07.1.0.1 _ _ _ _ _ _ _

uonironino penion I rmmr_SMEM M'IlNS._M--------

85 10 01 85 in 31 70

@{M $@

I t

PROM M8E8.T.12N_@g M_gy$.g I

YEAR uO DAY YEAR MO DAY 3

cro-n > in np 04-n,

asni on n> oost, NOTE: Reed InstructioRe betere cosupletIRg this forRs.

(J Card Onfr) OU ANTITY OR LOADING c4 Card Onfr)

QU ALITY OR CONCENTR AYRON

'" ET!,"C' SAMPLE PAR AM ETER (dd-33)

($447)

(J245)

(46,3J)

(5447)

NO.

TvrE Ex A= v; v.I.

i p,,,73 AVERAOC.

M AXIMUM UNITS MINIMUM.

AVERAGE M ARIM UM UNITS 00530 1

UMP's l

M E A.U R EM E"'

1/30 GR SOLIDS, 'H7mL E/L' 1/30 GR y

SUSPENDED

,,,P,gy wFrHFM (MfM 00530 E.

""^.A PLE 1/30 GR uREMENT SOLIDS, M SUSPENDED

, RM it E/L 1/30 GR N M IN N E REoUiMEMew

,t i

00530 4

. AM PLE 1/30 GR l

"'^*""***'NT SOLIDS, 'H7mL 30,00 100.00 N/L 1/30

,GR.

SUSPMDED n, Pe,R,m4r EFFWENT NET

  • ~ *
  • 00556 1

= AMPLE 1/30 GR l

OIL AND GREASE

~

T*

. **4 1/30 GR N/L reRMir

  • ~

RaouiREMEm gg 1/30 GR 00556 B

MEA AMPLE e

UREMENr OIL AND CREASE STREAM ING7E Psione:T -

M/L 1/g g

REau RsMENr 00556 4

M E A.AM PLE 1/30 GR UREMENT OIL AND GREASE

/L Penmir.

10.00 1/30 GR neoUiREMsw g

SAMPLE e,

MEASUREMENT PERMlf R EQUIR EM ENT

~

N AM2/ TITLE PRlNCiPAL EXECUTIVE OFFICER THIS DOCUMENT Is SIGNED WITH RECOGNITION TH AT MNOW-TELEPHONE DATE INGLY M AKING A F ALSE CERTIFIC ATION ON THIS REPORT OR

/&

J. Trej.o eUPPORTiNo DOCUMENTS OR iN T ENTiON A Lov TAMPERiNo Rad. Prot./Chan. Manager Orr EN.ANY MONITORINGEE in U.s C. 5 ioo E ORAND s s u.e C. sisie.

uws-esaN uRE Or PRiNCiPAd Executive 609 339-4399 85 11 22 WlTH OfVIC M ET HOD ARE CRIMIN AL Es.

eles under these statutes mer he fenre up to 110 n00 and/or onewimune A

OFFICER OR AUTHORIZED AGENT NUM B ER YEAR MO DAY TYPED OR PRINTED

  1. mprisonment of heteren A enunths end J peers.)

g COMMENT AND EMPLAN ATf 0N OF ANY VIOLATIONS (Mrferrare all etterhments Arre p s

No Samples were obtained due to entrairment study sample equipnent cx>nfiguration.

PAGE OF)g ffpA Fairm Wft-1 (ARv 10-7n PREV 10us EDITrON TO BE USED (REPLACES EPA FORM T*40 WHICH M AY NOT BE USED.)

NATIONAL PORuTlm DisCH1RGE WMr*C. TION CysTEM (%rfCJ 7,,,,, j pr.Mmec NAMe,Aoo

,,.,4,g

" '" ",i',,,,

om Aw s5 sam

"^

,.' [ *"'"s"*EY M 2-ENV AFF

-m P. 5 e F T G.----------

'TJUUU57iz ?

I 433 GP AT MI

',o,,--

17 7 I

- - - ~ F ~O' BUL 1 '.~~-----

--~b. W 570_10CM MTDT-----

re amiT NuMeca o =CMAaot NuMara

~

ECIr-SADEM WNE6LTINGY.5~TATION oA7 vY MO OELAWARE RIVER

- - - - - ~ ~

TrAR MO oAv COOLING WATER h22Eb_

_N _ _ ~_ _ _ _ _

'a "

85 l_0_ _Q1,_

'o

_ tie v,

,:s M ' M s NOTE: Read instructions before completing thie form.

85 10 31 rie si, in 9

<24 <,

f H erdf 8*48 Qu ANTTTv OR LOADeNG

  1. 4 ( ard Hahl QuaLfTv OR CONCrNTR ATION IA E

Id8 I f*d 8'I I'8 d'J I48 ' O I'd df8 or PA R AMETE R y

A~As

,,u,,

AvrRAGE maximum uMITS MINIMUM AVERAGE MAItuuM uNTT.

,gy.g gf pg egy pg, pp, 00010 2

TEPPERATURE, WATER

  • <Iiu"a?Erw 15.30 19.30 23.20 CONT NA DEG. CENTIGRADE DEG.C INFLUENT arou'arMem CONT UUU10 1

,,,,L, TEMPERATURE, WATER McAsuarMem 18.20 26.30 39.50 0

CONT NA DEG. CENTIGRADE DEG.C EFFLUENT GROSS arou'a:Mr=

46.00 CONT UUUlb 4

TFMPEPATURE

  • <IUu"a7Er=

0.00 7.00 16.70 2

CALC NA DIFFERENCE OFG C EFFLUENT NET aeS".70eNt 15.30 U U 4 U L, 1

PH McIUu"a7EcNT 7.30 7.70 8.00 0

2/7 GR SU EFFLUENT GROSS arou.M,7 er RrMcNT 6.00 9.00 2/7 GP C0400 2

,,,,y PH McAsuarMcNT 7.20 7.75 8.30 2/7 GR SU

.M T INFLUENT REQutReMcM 2/7 GR 5CC50 1

FLCW "eAsuarMcNT 0.00 259.20 532.80 CALC NA MGD PE RMIT EFFLUFNT GROSS arOu acme" CONT 50U64 1

1/30 "rfu"a?IeNr

<0.01 0.01 0.04 0

min GR CHLORINE, FREB

'?

KG/DYr MG/L RESIDUAL EFFLUENT GROSS nr O E 0cNT e * *

  • 0.20 0.50 CONT NAMe, TITLE PRINCIPAL rRrCuTIVE OFFICrm uM NT is stGNrD WITH Nr C NITI N TNAT RNOW gs TgtgpNoNg oayg f.,Acg J* Tre4o suceO=nNG oOCuMcNTs On imemiON Atty T AMerniNG Rad. Prot./Chen. Manager o.rrrN5ES 555.'.s.u s C. e ioOi ANo 33 u s C. i.i 3 v.CaIMIN AL o,,,,,NC,,,L Et,(Cur,y, 609 339-4399 85 11 22 l

WITH ANv MONITORING DEVICE OR McTHOo ARE

<ra

,,ou, sa

., s. sue.ooo

.di.,....,

z.r a,.--...,. d e 11...

..s.,

a s...

OrriCr= O= AuTwOnirro AGem

^"#

~

r

.s NuMerR vrAn MO oAv Tvero On eaimeo COMMrNT ANO eEPLANATtONOF ANT wtOLATIONs (#rfereere e4 e,rer4-en,e erre, DISCH 483 IS #13 COND COOLING WATER.

NOT MORE THAN 3 COND MAY DIS TOTAL OR FREE CL AT ANY TIME, AND NOT, MnnP THAN 30 MIN EACil TIME, r n a r... Steen, an, g rt.7T) Perventf*B rristinas tri er e tern eRFPt ACrS F PA F ORM T 40 WH6CH M AY NOT 9t uSFD D PAGE c; OF, o

PERMITTEE TAM'/ApostEse (farfisde Zf.700NAS W d N N E GMALI2.0 N CJgW rerskov ivamelleressen el d*0erene)

Ot: CHARGE MONfTORIN3 CEPORT (DM;)

OM2 Ns. IM R0073 F

(246 OFJU

'Bam_.E_ l@!..MG_R,;'_ W_ g_

~

PSE&G MI0005622 483 GP.At MI

ageags, Pr2"'T NUMeES:

oirc A.EE u

='a 17 7 1

,i.. _ _ P.AQA. B@-__570 i nc __ _ _- -

=

_M__ _ _

MI._.O.7.lOl--------

MONITORING PERIOD

' mamr S % E _ N M G_.S_ W E N.- - - - - - - -

85 10 01 85 10 31 MLIE E'JE

. F.

FROM TO 1 M $.T.!C,M_,,, m,,,__m_ m_ _ _ys _ N_ _ _ =_

YEAR Mo OAy YEAR Mo Day NOTE: Reed instructions before conspletlRg thle forni.

aas in.n> adaJ)

Oh vs <>as,,

( an, (J Card OnIF) oU ANTITY OR LOADING (d Card Onfr)

QU ALirY OR CONCENTR ATION PAR AMETER (46-33)

(J447)

U43)

(46JJ)

(3441)

NO.

FREOUENCY g gg pgg gp Ex TvPs AN. m..

,,,,,3 AVERAGE MAXIMUM UNITS MINIMUM AVERAGE.

M AXIMUM UNITS

  • ^ " ' ' '

58.00 58.00 1/30 GR 00530 1

MEASUREMENT SOLIDS, 'IUIAL

""'T m/L 1/30 GR ED R Eo"u'lR EM ENT j

1;'PT:' TIM NC l

00530 B

  • ^"

1/30 GR M EA e U R E M ENT 16.00 16.00 SOLIDS, 'IDIAL SUSP N ED PE*" 87

/L 1/30 GR q+ -;

REoUiR EMENT mm Tunw 00530 4

. A M Pot MEASUREMENT 42.00 42.00 1

1/30 GR SOUDS, M SUSPENDED PERMIT 30.00 100.00 MVL 1/30 GR

"'*"'"*"""T mm NE'r 00556 1

. A M ett

<5.00 1/30 GR M*A*uaEarNT OIL AND GREASE

,ER M,'r KVL 1/30 GR REoU REMENT EFFrFN'T GR)SS 00556 B

j i

MEA.A.,LE

<5.00 yn g

uREMENT OIL AND GREASE STREAM INIAKE m/L 1/30 GR PsRM 7 REcuiRsMENT s

00556 4

" "^ A.,LE 0.00 0

1/30 GR uREMENT OIL AND GREASE 10.00 MVL 1/30 GR' cERMiT.

ReoUIREMaNT ggg l

SAMPLE M E A sU R EM ENT

{

r PERMIT R EQUIR EM ENr TELEPHONE DATE THIS DOCUMENT 19 SIGNED WITH RECOGNITION TH AT MNOW.

NJ.M2/TOTLE PRINCIPAL ERECUTivE OFFICER INGLV M AMING A F ALSE C ERTIFIC ATION ON THIS REPORT OR

/

r eUPPORv No DOCoutNTs OR NTENTiON ALLv TAMPER Na I

J. Trejo CR f M IN A,L RE OP,R,NC. PAL 4EECUTivE 339-4399 85 11 22 WITH ANY MONITORING DEVtC METH ARE Orr E N=E*.

  • E E s e u.s C. 5 ioo.E ORA N o a s u.ODC. si sie.

c rem r.

.loN A Rad. Prot./Chan. Manaaer sire unter these sentures mar he pare up to $80,0t*0 nnd/or mewimune A

A OFFICER OR AUTHORIZED AGENT NUNDER YEAR MO DAY g

g TVPED OR PRINTED empegrunment of beterren 6 me.nihe end J 3 ears.)

COM M ENT AND EM PLAN AT80N OF ANY VIOL ATIOMs (Reference en a#sachment, here p PAGE OF r-n e e%

91979 4 FDaw ifL77) PRFVfOUS EDITION TO BE USED (REPLACES EPA FORM T.40 WHICH M AY NOT BE USED.)

4; 1R

\\

N

  • TION
  • L POLLuTENT oesCNAfeGE ELiessNATiON "YsTEM (%PDe$)

7,j paneerTTer mAess/Acontes f m pues,,h

/t. rare rdyw-rs DISCHARGE MONITORING REPORT < twas g y jjyg g,g jpggyy w - 6EM-MGR-ENV-AF, r --

,2 n.,

,,rea M Q.S.E. & Go NJ00056??

I 4H4 GP AT MI 4_570 10C PraMTNuMera o..CNA or NuM.e.

17 7 I iRJTf0F--- -

N Ec7u-SALEHENM'flW3iTTIOT---

oA7 TE MO DELAWARE RIVER

,,A.

MO oA, TMlTWWTLLITWTY5 CTE_EK r OM;,,a,s 1,0,,,, n,,i,,,

8 5,,,

1,0,,,, 31,,

~

TO COOLING WATER toc

,84.rdf8 4)

QUANTITY On LOADING

,4 ( #d f#a%#

QUALITY Oa CONCrNTR ATION PARAMETER

  1. dedIJ f'# 8II I'# d'I Id* "3 IWII yy ANALYSf6 I'

AvrRAGE M A XIMuM UNITS MINIMUM AVERAGE M A RIMuM uMITs f62-471 fedWJ

  1. 99 707 0C010 2

"** *v""I"*"

15.70 19.60 22.70 CONT NA TEPPERATURE, WATER DEG. CENTIGRADE DEG.C

~

l

~'

,,,M,,

)

INFLUENT e***

CONT

""^su"a?M<NT 19.40 26.70 32.00 0

CONT NA eeee eeee F

RATURE, WATER DEG.CENTIGRACE DEG.C i

EFFLUENT GROSS

'8 0*"* "'"

    • e*

46.00 CONT 00016 4

0.00 7.40 12.50 0

CALC NA TE'iPFRATURE McAsuarMsNT eeee eeee DIFFERENCE DEG C EFFLUENT NET

=EOuineMe" 15.30 M. As'u"a? Jam 7.40 7.70 8.00 0

2/7 GR e**e p

"'E' cNT e***

6.00 9.00 2D M

EFFLUENT GROSS 0

2

,y,A"a?JsNT u

eeee e***

7.20 7.75 8.30 2/7 GR p

INFLUENT 5C050 1

Mal.*u"a?JeNT e,,e eeee 0.00 490.50 532.80 CALC NA ptgy MGD

~

ennen CONT EFFLUENT GROSS 5CC64 1

1/30

. A.,t, Cl8LCR I NE,

FREE' "c Asuar Mac e, * *

      • e

<0.01

<0.01

<0.01 0

min GR i

KG /D 'a Y MG/L l

RESIGUAL

,,,,e,,,

EFFLUENT GROSS 0.20 0.50 CONT NA TrLeeNONe oATr

,T N;s, Og,MgN T, ig,op eg,=,,i,q,a,rgo ogfig,, T g T,,ypO,w; N2Meniftr mNei AL esecuTive 0,rica.

J. TrOJO s u P POa T I NG oOCuMcNTs OR INT r NTION A LL Y T A 04Pr RING

[

WITN ANT MONITORtNG OrViCr OR McTHOD arc CRIMIN AL

,r,

,,, o,,,,,Nei,AL &rcuTive 609 '339-4399. 85 11 22 3ad. Prot./ Chm. Manager OrrrNsrs. sur is.u s C. i ioOi

. is....,,s u,,s... s..si.,.....

c. i m i e.

ANo a

,,o 4

..s,...............,

l vrA=

Tvero on mMTro r.ia - - e

<a.

-e*, = s O icra On AuTNOairro AGam g^

j MO oAv NuM.cn COMMcNT ANo EEPLAN ATIONOF ANY WIOLATIONs

,Jrefere c.

5.rt.rt Aeres DIS 434 IS #21 CONDENSER COOLING WATER.

NOT MORE THAN 3 CONDENSERS MAY DIS TOTAL OR FREE CHLORINE AT j

ANY TIME, AND NOT MORE THAN 30 MINUTES EACH TIME.

l,

PERestTTEE NAtSt/ADORESS (Isr8adr N ATION AR. POLt.UTANT DISC %f.ROJ ELIMINATDON SYSTEM (MPDF.5) l/orset (JplQ Far84rr Na=M/ Lor *88ea fJ d88er).

DI CH ARGE MONITORIN3 REPORT (Dw2)

OMJ Ns. US R0073 mas g _9,, J3W.f _ER.. _W_@_ __ _ _ _ _ _

(24*

('74')

ageRgap_P_SE_&G.___4 RT0005622 GP.AT MI

_ RAQA.BOR 57_0_-_

10c _ _ _ _

17 7 1

PEIMIT NUMBE2 oleCHAME DeUMIER M

4I._.02101-_ _ _ _ _ _ _

MONITORING PERIOD raca.ur_SOLRLGMllN_G SMpH --------

85 10 01 85 10 31 rROes TO COOLING NA'IER AgC._4yjstN_IOfER_M_ _ _YS CR_E_E.K_ u _ __ _ _ _ _ _ _

vEAR MO DAv vfAR MO DAv cia-n > inas udJ5:

U6 na va-np 0 0-88,

NOTE: Reed IRetnsctioRe before colupleting thle forni.

(J Card Only) OU ANTITY OR LOADING (d Card Omfy)

QU ALITY OR CONCENTR ATION PAR AM ETER (46 JJ)

~~d47)

(1843)

(46JJ)

(3441)

NO.

reEouteeCT g g,g pgg gp EI TVP' ANALV$lt 7)

AVERAGE M AXIM UM UNITS MINIMUM AVERAGE M AXlMUM UNITS 00530 1

,,,,A""'*

UREMENT 29.00 29.00' 1/30 GR SOLIDS, 'IUIAL SUSPMDED

,,,P,g,87ENT

~

FFFTIWhTP N4

  • *I* *-

m/L 1/30'

'GR 00530 B

.AM,LE 1/30 GR

"'**uaE* Ear SOLIDS, 'It7IAL 65.00 65.00 SUSPM DED

,ERM iT MG/L 1/30 GR

"'*"'"'"*"?

STREAM INIAKE 00530 4

M E A.A M,tt 0.00 0.00 0

1/30 GR UREMENT SOLIos, 'IgrAL SUSPmDE PERMir 30.00 100.00 m/L 1/30 GR N NET

"'*U'"'"*"?

00556 1

. A M Pi.E M E A s U R EM ENT

<5.00 1/30 GR OIL AND GREASE

~

m,p ggggg RaouiREMENT m/L 1/30' GR PERMir 00556 B

M E A.A u Pot uREMENT

<5.00 1/30 GR OIL AND GREASE STREAM INTAKE PERM 7 m/L 1/30 GR

~

REOuiR eMENT 00556 4

. A M,LE 0.00 0

1/30 GR OIL AND GREASE

"'**""*"'"?

PERMir.

10.00 m/L 1/30 GR M EQUIR EM ENT g

SAMPLE g

e, MEASUREMENT w

PERMIT REQUIREMENT NJ.ME/ TITLE PRINCIPAL ENECUTIVE OFFICER THIS DOCUMENT IS StGheED WITH RECOGNITION TH AT MNOW.

TELEPHONE DATE

/Ay' INGLV M ANING A F A LSE C ERTIFIC ATION ON THIS REPORT OR J. Trejo su PPOR TiNo oOCuM rNTs OR INTENTION ALov T AMPER No 609 339-4399 C R IM I N,.A.L,. eiONgURE Or PRiNC4AL Executive 85 11 22 WlTH DEVICE OR M ET HOD ARE Rad. Prot./Gan. Manager o r r E N.A N.Y.M O N S T.O R I.N G.C.,,Oo, ANo 3 3u...C. si si..

ir E. EE u.

sies eneder cheer sentoses may he pere esp en 110,000 and/or mesimum A

A TYPED OR PRINTED empreseemeer of p,e.,c= 6 muerhe and 3 peers.)

OFFICER OR AUTHORIIED AGENT NUM BER YEAR MO DAY c

g COMMENT KND EMPLAN ATION OF. ANY VIOLATIONS (Referrore eH etterh= rats here)

Ep A r,wm ' tun.1 inaw 10 773 PREY Ous EDITION TO BE USED f REPLACES EPA FORM T.40 WHICH M AY NOT WE USED.)

PAGE. g OFl'8~

NATIONAL POLLUTINT Ot9CHAftGE EltestNATION SYSTEng (gpipas8 FwA PEmmerTTEE peAssE/AcDREse afm end, DISCHARGE MONITORING REPORT tost:s

  • M'****'

(=mp h.=,/ s ereshe r m -- GEN 5 i-EC'.4~AFF

" U #' "

I GP AT.FI A U N __ M_* 9 _'_ 9 4Rq 17 7

I D O 570_ 10c ~ ~

i PraMiTaUMacR o'*CMAmor auM=ER


fd%. BOX

-.% UTC)I-----

i u

oY"'

v AY MO DELAWARE RIVER T,TT~~$XDN GENERATINGi.ST'ATION vEAR MO DA, Ac

~

COOLING WATER MT2M[_MUN P_@F ~~~~~~

[85 10 01._.

70 85 10 31_.

raOM vie sis se Jis rJe Jas tie 2's r2s 2*s e se fis NOTE: Reed instructions before completing this foEm.

t 8i es fJadyf OUANTTTY OR LOADeNG (d ( ard,7mirl QU ALITY 04 CONCENTR ATSON

      • UI

'M *ll f * *'E

      • 'I 4%'*l0 y

FARAMETER

""'8'8 (tJ.17J AVERAGE 80 A EIMUM UNITS MtNIMUM AVERAGE teAMit4UM UNITS te24f/

fed e87 5 78) 0GG10 2

CONT NA TEMPCRATURE, WATER MEASURE = m 15.70 19.60 22.70 DEG.C DEG. CENTIGRADE INFLUENT arou'a*Mem CONT 00010 1

...,t, CONT NA TEMPERATURE, WATER "EAsuREwNT 19.40 26.70 32.50 0

DEG.C DEG. CENTIGRADE EFFLUENT GROSS acEEEE" 46.00 CONT

~UCuLb 4

.AMPtE CALC NA TEPPERATURE

"<asvat= NT 0.00 7.20 10.70 0

UEG C DIFFERENCF EFFLUENT NET aEQuiMwNT 15.30

,ER

,T OC400 L

2/7 GR pH MEASURE = =

SU EFFLUENT GROSS aEOutREMem 6.00 9.00 2/T GR PERM,7 0C40G 2

2/7 GR

,,,,y, PH "EAsUREMEm SU arou'aE"<"

?/T GR PE RMt1 INFLUENT SC05C 1

" A Eu"REe=

0.00 490.90 532.80 CALC i NA FLOW

'4 GD

    • E E ENT CONT EFFLUENT GROSS 5C064 1

1/30 UR7MEm

<0.01

<0.01

<0.01 0

GR

,,3

CHLORINE, FREK "EA RESICUAL KG/ DAY dG/L EFFLUENT GROSS a*EEEr=

n.20 0.50 CONT NA NAME/ TITLE PRINCIPAL EXECUTIVE OFreCER T

D to NT IS SIGNED WITH RE GN TION TH T INOW TELEPHONE DATE

[

[

sUPPOR TING DOCUMENTS OR INTENTION ALLY T A MPE RING J. Trejo ME ** OD A RE.CRIM,IN A,L 609 339-4394 85 11 4.2 WITH ANY MONtTORING DE VIC E OR Rad. Prot./Chen. ftnager u,...,,,..sE <.,',,,,U,s C., i o0,.,A NO 3 3 ; s..c.

,,,,g,f,, o,,,,,c,,,,,4 coy,y, isi.

r, orrE asES.

e

,...., f..,

..df.,...,...

A TYPE D OR PRINTED

  • f A*'**** * *aates s.4 9 peer. i OFF#CER OM AUTHORerED AGENT NUMBER YEAR 98 0 DAT g

COMMENT AND EEPLANATIONOF ANT veOLATsONs (Nefereer, e#.rter4.ress Are,)

015 405 15 CONDENSER #22 COOLING WATER.

NOT MORE TIIAN 3 COND MAY DIS TOTAI. OR FREE CIILORINE AT ANY TIME, AND NOT MORE TilAN 30 MINUTES EACII TIME.

No sanoles were obtained due to entrairment sttdy sanple equipnent configuration.

rrin ra,= 11 % i,0.w trL7Tg PREvsOUS EpsTION TO rte u%ED (REPLACES E PA FORM T-40 WHICH M AY NOT BE USED I PAGE q OF 18

PEnMITTEE NAM '/ ADORES (ferfude NATION' L POLLuTA%T DISCH ARGE CLIMIN '. TION SYaTEM (NPDES)

Nor8R W' Forsasty Name/teceedea c d##ercar) ogSCH AZGE MONITOF.iNG REPORT CM2)

OMJ NA 158. A0073 568CR _ $ _* O_~_~_ Y _ Y _ - _ _ _ _ _

(Id

(#'

,e_oo_nsm _P_S._E.&G_

MIO005622 485 GP,AT MI 17,)

{

P R _BOR.S7,0._ lDC._ _

PIM87 NUMBER oescumE NUMSTR

_._ )O N


MI._.02101 _ _ _ _ _ __

uoniroRiuG PcRico N

r.mairr_SM8_N'UNG. N--------

85 10 01 85 10 31 rao" To COOLING WATER MT.iO_w_L_OWFR ALIDM_Y.S CREEK-e--- =_

YEAR MO DAY YEAR MO DAY (JoJi) (22-233 414J5)

(16 J7) (28J9) (80J1)

NOTE: Reed instnsctions before cosRpledng Wile forni.

(J Card O=1 ) Qu ANTITY OR LOADING (4 Card Only)

QU ALITY OR CONCENTR ATION l

7

'"E",",'"C' PAR A M ETEa (46 JJ)

(344f)

(145 p (46,31)

(3447)

NO.

S AM PLE EA TYn AN.L,...

AVERAGE MAXIMUM UNITS MINIMUM AVERAGE M ARIMuM uMITS 00530 1

. AM PtE M E Asu R EM ENT 1/30 GR gonym, m m/L SUSPENDED PERM T 1/30 GR REauimEMsNr N GBOSS 00530 B

. A M PLE 1/30 GR M EA su R E M ENT g,g SUSPDOG PE=M '

m/L 1/30 GR

""'"'"'"T S M INTAKE 00530 4

. A M Pi.E M Easua EM ENT 1/30 GR SOLIDS, M SUSPENDE P'*"

30.00 100.00 m/L 1/30 GR PIN NEr 1

00556 1

. A M Ptt 1/30 GR OIL AND GREASE "EAsuREMENT nRMiT m/L

^

'1/30 GR I

EFFw mf GROSS RaouiREMEur 00556 B

. ^ " " ' "

1/30 GR OIL AND GREASE SN N

        • ~

m/L 1/30 GR rec"uiRsMsNr j

i 00556 4

. A M,,,

OIL Ato GREASE MEASUREMENT 1/30 PERMIT.

10.00 m/L 1/30 GR EFF W WF NUT RaovmEM sNr S AM PLE MEAguREMENT g

PER MIT REQUlM EM ENT NAM 2fTITLE PR;NCIPAL EXECUTIVE OFFICER THIS DOCUMENT IS SIGNED WITH RECOGNITION TH AT KNOW.

TELEPHONE DATE INGLY M AKING A F ALSE CERTIFIC AT80N ON THIS REPORT Odt (A

J. Trejo s u PPOR TiNo DOC u M E NTs OR INTENTION ALLY TAMPER No

,09 339-4399 85 11 22 Rad. Prot./Chan. Manager OrrENsEs. sEE in u.s C. 5 soOi AND s s u. OD ARE CRIMIN.AL WITH ANY MONITORING DEVICE OR M ETH

.iaNpRE Or PR,NC,6 EMEcuTivt 3

.c. sisis, i r, es.

enes umfer shene stesures meer fence esp to $ltl,tMF andler mestmum desprisommcgr of herwere 6 mogr.he A

A e and J seers.)

OFrICER OR AUTHORIZED AGENT NUMBER YEAR MO DAY TYPED OR PRINTED g.

g COM M E ~ T.-..... M..mM n, A N v,OL A T lON R,,,,,,,,e,,e.,-...A,,,,

No samples were obtained due to entrainment stixly sample equipnent configuration.

jgOF )g spa rewm iv2tL1 (Aav tri.77) PREYlOuo EDIT ON TO of usED s REPLACES EPA FORM T.40 WHICH M AY NOT RE uSED.

PAGE

MATioNAL,oLLuT ANT of9CNARG, (190stNATeoN CVSTeu (%Pota, pg,,, J penurrywa mAase/Aeoness w DISCHARGE MONITORING REPORT taswa, OM)N3158-JNef3 P'1E_=E._3E.'_MAfF Z_~-_T pae,rs m,f t mas.,ap e SE 4J00C%77 I

4M6 GP AT MI

.A.on.s!s!!s. _3 2. _& G._,,

17 7 p

nnY 570 10C__

ec==iv Nu== =

oe=CNA=oe NuM===

. NJ~07 G T _ _ _,,,,__,

NW k

~

r

~'.'L,7,"

SKLEM 5ENERA'fING STATION Y

=O DELAWARE RIVER

~

~

veA.

o y A oA, AC rao

85 10 01 To 85 10 31 COOLING WATER LOWlR ALLOWAYS CIEEK

~~7

~-

Q-T, n f3(edOa4#

QUANTITY 088 LOAotNG 88 ( ed f8a8 i QUALITY OR CoNCeNTRATIOes P

OA I" 9 'A l'8 #I8 I" d'J f#III (9#4II p

,AAAte:TeR Aharvae i

AvenAos MAXIMUM UNITS MIN 6teuse AveRAme MAEtteut0 upstr$

gg,4 peg gggg g>>.sr, 15.70 19.50 22.70 CONT NA u"=7ENT

=A T P8 RATURE, WATER DEG.C DEG. CENTIGRADE

,e,,,,,,

CONT INFLUENT 18.60 25.90 33.40 0

CONT NA RATURE, WATER DEG.C

~

DEG. CENTIGRADE

,e,,,,,,.

EFFLUENT GROSS

"'ou'"* ""

46.00 CONT GC016 4

0.00 6.50 11.90 0

CALC NA

"* A5u""IE*"'

TEMPERATURE DIFFERENCE

- DEG C

,e,,,,.,

EFFLUENT NET wouine m 15.30 OC400 1

7.40 7.70 8.00 0

2/7 GR wAIu"n?Em

$ e *

  • pg SU

~

neou

,7 eeacueNT

(.

00 9.00 7/7 GR EFFLUENT GROSS 7.20 7.75 8.30 mellu".7 Jew 2/7 GR p

SU es,,

2/7 GR INFLUENT k

mellv".7Je=T 0.00 465.10 532.80

+

CALC NA MGD

~'

,ener7 EFFLUENT GROSS neouine===T CCNT 50064 1

1/30 nd.n GR

=*A. a "

CHLORINE, F R E E'i

' 3 KG/D%Y

iG / L

~

RCSICU4L EFFLUENT GROSS wou.amw 0.?O C.50 CONT PIA Tete,No.,e OAT.

NamemTte miNeinL esecuTive orrice=

g,o g uiga= T, is,,gNe o,,wgN,y,rgooN;Tig,,TgTg,No,4

[

IN g.

J. Trejo s,u,P,Po a,v,i N,o,g,q u,M4N gogg N T,,e N4'o,N A,' L,v,,7 Ap r,c, a;g 609 339-4399 85 11 22

,,o,,g,(,,,c o,,,,,,c,n(f ecuTive Rad. Prot./ Chem. Mar.ager o'raNsrs. see is u s C. e iooi ANo 33 u s c. e isie.

,r e

"" ""#" 4 'J.!!.".'"." *.'.J',d","

orrican on AuTNoaireo AmewT g

Numeen veAm no OAT Typeo on e.,meo COMM2NT Aho axPLANATIONOP ANY vooLAfgONS #Neference ss aremamenes Anes DIS 486 IS COrJDENSER # 2 3 COOLING WATER.

NOT MORE THAN 3 COND MAY DIS TOTAL OR FPEE CIILORINE AT ANY TIME, AND NOT MORE THAN 30 MINUTES EACH TIME.

PAGE 14 OF gg FD A Fewen 117fL1 f opy 10 77) enevsOUS COITION TO Re u*bEo tRcPLACeS FPA FORM T AO WNICN M A, NOT BF UsED :

perm TTes mAMefAnonese (se m;T:Ow At. eOi.e.uT:NT os.CwAmat EuM =:TiOg eveTsw (m.

_f per88ffF NenM/Eatedden Q diferr"'I DISCH ATE MONIT:CIN 3 REPORT (DAt!)

OMJ

.154.R6073 mam_s_ R._m_R.__@_@ _,, _ _ _, _

(i.us (tr.se)

I l,etta_4Ep PSE&G fU0005622 486 ap. Ap pg P5MIT NuMBEQ DISCuaa.ct poussetR 17 7 1

]

.,f_AQ,. BOf 570___ Ifro s

-__ = - - -

__)B82K

_.ML AllDl--------

MoniTonlNo PEnioo J

I racts,in SMm_GER_AT1N_ _G _6---------

85 10 01 85 10 31

@M MM 9

FROM TO M g M.---

YEAR MO D4Y YEAR MO OAY MT,jgM (20J#) (21-21) q J413)

(26 J7) (28 19) (3<Lil)

NOTE: Reed IRecructions before consplotlRg Wile fome.

e (J Card Only) oU ANTITY OR LOADING (4 Card Omfy)

QU ALITY OR CONCENTR ATtON 8#,8 C SAMPLE PARAMETgg (46-3J)

(3441)

(JMJ)

(46JJ)

(3441)

NO.

"E U

TYPE ANALYST 9 AVERAGE M AXIM UM UNITS MINIMUM AVERAGE M ARIM UM UNITS g

00530 1

. AM PLE SOLIDS, 'IUIAL 52.00 52.00 1/30 GR

"'^'""'"'"'

M PENDED n a"

  • * * ~*

m/L 1/30' GR N GBOSS 00530 B

" '^.A M,L E 89.00 89.00 1/30 GR uREMENT l

SOLIDS, 'IUTAL l

SUSPENDED es=M sT m/L 1/30 GR RaouiREMswr I

STREM DTDKE 00530 4

. A.,t f 0.00 0.00 0

1/30 GR

"'^suREMENT SNDS, 'IUIAL EFTUJDTI NEP

""*"'"""*"?

30.00 100.00 m/L 1/30 GR SUSPENDED

    • *
  • T 00556 1

. A M Pi.E

<5.00 1/30 GR l

OIL AND GREASE Rao"uiREMEur -- * * *

  • m/L

^

1/30 GR

"" 't N GROSS

<5.00 1/30 GR I

00556 B

,,,,t, MEA.uREMENT OIL AND GREASE PsRmT m/L 1/30 GR l

STREAM INTAKE REcuiReMswr 00556 4

. A M Pi.E 0'00 0

1/30 GR MEASUREMENT OIL AtO GREASE 10.00 MG/L 1/30 GR neo"u'is"E!Isier S A M PLE MEASUREMENT g.,

. PERMIT R EQUIR EM ENT N AM3l TITLE PRINCIPAt. EXECUTIVE OFFICER THIS DOCUMENT 19 SIGNED WITH RECOGNITION TH AT KNOW-TELEPHONE DATE J. Trejo

$NGLY MANING A FALSE CERTIFIC ATION ON THIS REPORT OR

/M' e v PPOR TING oOCuM ENTs OR INTENTIONALLY TAMPER No WITH DE OR M ETH ARE CRIMIN AL

"]g.fg S Rag. Prot./ an. Marnger Orr EN.AN.Y.MONITORI.NG. o. .C. g.VIC,EAuo 3 3 u..OD.C. sisie. i ce-ei. . aNAT Or rRiNCiPAt ECuTivE sog 85 11 22 E. EE oo 06es umfre sheer sterwere seene he pure uP to $10,000 and/or eneentmune A A OFFICER OR AUTHORIZED AGENT NUMBER l YEAR MO DAY TYPED OR PRINTED deprisonment M he# ween 6 mwer4e and 3 3rees.) g COMM ENT AND EM PLA N ATION Of" ANY VIOLATIONS ( Arferrare eN afferhments Jerre) FAA Fnem Wo.1 (ARv 10 77) PREVIOUS EDITION TO BE USED (REPLACES EPA FORM T.40 WHICH M AY NOT BE USED.) PAGE F 12 19

PEResfTTEE NAIGE/AODRESS rpm NATIONAL POLLUTANY DISCHARGE CLIMIN ATION CVSTEM (%erJf37 _7 j DISCHARGE MONITORING REPORT trassas Mf8hWMJ ine me=,/t_CEf ;763#-EN'J-A FF-,- r N ,,,.,3 M p. h Fo T E N J U U U'2 6 / :' I t tu, GP AT.MI ___gp EC~ - SA N T M E M I T.5 TAT M ~ ~ ~ ~ oY vE MO DELAWARE RIVER o,, ny vEAR MO toc,,,,,,TUWIR71.T OWKT5 L M t tK~ -------- , ROM 85 10 01 To 85 10 31 12e los un 2 en ou 2<> ru-2ro ru-zes a wef> N OTE : Reed inetructione betore comploting this fofm. f f( edf8a4# QUANTITY OR LOADeNG fd i ad #8 47 OUALITv OR CONCENTRATION PARAmeETER fd8 "8 i'd'* f 8 888 8'# 8" ' 'I f9#881 8A I y ANALv$3S g gy.. AVERAGE M A EIMUM UNITS MINtMUM AVERAGE MAXIMUM UNITS gy.ggj gog ggj pyg, yg, UUULD 'e SAMPLE HEAT FILLIONS CF MEASUREMENT 0.00 9916.30 18267.00 9 CALC NA BTU'S PER HR NET "HTUHR PE RMIT EFFLUFNT NET REOu'aEMENT 16300.00 SAMPLE MEASUREMENT PERMIT REQUtREMENT SAMPLE MEASUREMENT PEpterT REQUIRE MENT SAMPLE MEASUREMENT PERMfT REQUeRE MENT SAMPLE MEASUREMENT PERMt? REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE ND MEASUREMENT 3 PERMIT R EQUIRE MENT N1ME/ TITLE PRINCIPAL EIECUTtvE OFFICER THIS DOCUMENT IS StGN E D WITH RECOGNITtON THAT 8t N O W-TELEPHONE DATE INGLY M A st tNG A FALSE CERTIFIC A TION ON THIS REPORT OR /Ae J. W eio SUPPORTING oOCuMENtS OR iNTE NTiON ALLv T A MPE RING J WITH ANv MONITORING O E VIC E OR METHOD ARE CRIMIN AL ATu E Or P Aii>AL executive 6 339-4399 85 11 22 Rad. Prot./Chen. Manager o'.rENSES. SEEas........<,,..,e i OOi ANo 3,3 U S C,e.i s i e. s e u S C. <r d as. ..d. s, so...,,. sie.e .di., ...o..., l YEAR TVPED OR PRINTED dav*" --./ Ar8***. 4 =*ef 48.ed 9Fewei OFFICER OR AUTHO*tf2ED AGENT NUMBER MO DAY DE COMMENT AND E8PLANATIONOF ANY VIOLATIONS f#efsee.ra.o.rs.r4=e=#. A,,,p TCTAL GF DISCH 481,482,483,484,485,486 E Dm Cerm 119tL9 # Daw t fL77% PREvtOU9 EDITION TO RE LpSED gME PL ACES E PA FORM T 40 WHeCH M AV NOT BE USED I PAGE 1 q OF }g

Panamp namuf - eae 8 DISCHARGE I40NITORiNG REPORT (DaG) U MJ N;,IM.Agen 8 r.,, _a j;t!s,;_ gag,_*_i!y_Ag_' _____ _ ______ _ g.m o r.n, M70005622 48C GR AT DE l ssamer__PSE),,,,,,, ____,,,,,_,,__,,,,,_,,__ G A 17 7 1 ll f _P.AQA. 5 8.17_Q. 1DC._ _ _ J _ J s sutK _ _ __MI. _.07101-- - - _ _ - _ neONiTORiNG PERiOo NN man,ur SELM_NN-------- 85 10 01 85 10 31 !:AEGdLTJE81 N M 9L.E.E.- _ _ _ _ _ _ _ _ _ vuR mo DAv vsAR =O DAv noTn: noenn ansannenean menene eeaureenne eine sena. on n > <n-n> su.n > os un an.n> <nu, (J Card Onfp) GUANT8TY OR LOAOING (d Card Omip) GU ALif v OR CONCsNTRATION i m s> om>

uus,

<ms, om> =o. ~***;-** .Auns , AusT.R (33JF) AvsRAes esAstmeUet UNITS 301 nit 0Utd AVsRAes $$Aalupet WestTS g 00530 1 eAveLa usAeuR==sar 9.74 14.49 5.27 6.00 0 3 /30 24 g,7ng, g asoUimament 27.80 185.00 KG/DE

  • ***a 30.00..

.100,00 W-C/L .G L. 1/30 '24' SUSPHOED enmir mWENT usam Y 00556 1 umei. <5.00 0 1/30 GR h OIL APO GREASE ~ 10.00 E/1,

  1. 1/30 et
        • u"*"*"T j

,,,g,,,

  • l***-

) 00551 1 uuns <0.50 1/30 GR usAeumsus=T m ~ m/L 1/30 GR

  • I*?*~*~*.
  • * *;*L
    • t*,*

E "**"'T' 4, V. 4 O j EETWENP GROSS t 01042 1 u meLa 0 J/30 24 "***""'"*"T 0.02 0.02 <0.01 <n.nl j COPPER, 'ItymL 1.85 '1.85 RG/DE i* * ** '* * *'*J 1 }0 26/ 4 C/L f1/30 24 f ^ "8"' GROSS 8 01045 1 "sAYu"R?m' swr 0.53 0.70 0.29 0.29 0 1/30 24 IREN, 'ItymL ,,,, T,J, 1.85' 1.85 KG/DE .1.00* ~ 1._00f - C/L l. 1/30 24 's (AS FE) T gaggg } 50050 1 O 48 0 71 CONT NA u sAeu"m's'u sNT } m

  • * *
  • 5(.;

mooUimasseter

  • * *J*

CD esResiv i EFFWENT GOSS 30.70 30.70 0 3/30 GR 00610 1 uuns meAeuma===T m t. i,'; (AS N) e p uif 35.00'

  • * *~*?

s/L .1/30 GR mWENT M TsLs, MON: DATA pe ) Mate 3/TITLs PRINCIPAL sEsCUTive OFFICsN TMIS DOCUMENT IS Ss.G8eEO WITN RECOGN87 DON TMAY MMOW. f INGLY M AstING A FAL E OFS TlFIC ATIOM ON TMie REPORT OR DOCU M ENYaw OR INTEP4 TION A LY TAMPERING 85 11 22 ouPP.OR T s No de,frOJO Cni-iM,a L A Rad. Prot./ Chem. Manager O r,f.EN.ANY.=Es iT.Omi.No,OEv Cs ORANo a s u..Oo AR: CUvivs 609 339-4399 Wi ON u sT M ir s-esot/, As Oc emiMCieAtfk E. u. .C. 00

c. eisie.

Fears' ) O FICER OR AUTh05tlasD AesNT MU Sam JYsAR uO DAY ses of I TYPaD On entNTs0 f a 6 see 4e e f COMMANT AND EMPLAN ATION OF ANY VIOLATIONS ( Arteresere elf esserkmaass herap { i l i i PAGE OF ea. aaaa. art g et ??g perveOtse ro TION TO es USEO (REPLACES SPA FORM T-40 WHICH M AY NOT Ss USsO.) 3A 1R

DM J #e. US.Jt99/J DISCH ARGE MONITORING REPORT (Det!) Ferdwy Wa=M/teresena O demer) (87Je> ti ise I

  • maM_s _ pN_. _PC_R._ _B_W A_F.F._____ _ __ _ _

O nT0005622 4sc Gn a m - 17 7 1

.aenser_psgr.c_.__ ___._ _ _ _ - _ _ _

P.RMn aUM..a os.ee.t. 1.... _ AR.Ba1.5.7.Q.. loc._ ______ _._._ _ _ M ___E N -------- __.KI _.07.101 ------- MONITORING PERIOD l 85 10 01 85 10 31 $NetH_ N - 8'**" To YEAR MO DAY YEAR MO DAY . MTE _I. MER_- A_f J_fBG_WS _ __ 99070 M N W ee m sitsture. 1 I (JoJA) (JJJJ) (Jd 25) s26 27) eJeJf) ( Jtk J, ) e (J Card Onfp) GUANTITY OR LOADING (4 Card Omfy) QUALITY OR CONCENTRATION seO. 'stewtwo gauptg (d6JJ) (3447) (J8 43) (46JJ) (3441) oy I U ANALT999 PARAteETgg I (8 M ) AYERAes mAMiMum uNiTo newiMuu av5RAes mammum uniTo <0.01 <0.01 0 1/30 24~ t 01092. 1 ,,f,*,",n,*EwT

0. QO.V G h' @--

. Zinc, Total M~ f5 t Gross 8"Y i .AMm. e, - M EATU REM ENT v 8 [* ROGUIREMENT .. 5% p. 1- ' T -- A(t 4 ..A.AM n. a. uREMan? . s s.-_. ] REeutREM EDIT i.v.y PERttlT ,f g n,y n ,9 y 9j 7,. e i ..1 ..r. SAMPLE e ME ASU R EM ENT f." I ' 7 % ,g;, ,] pggggy' 8 _.,.y, f ,o,- f _,. w ..f 4 .y mEeu RaWENT 4 3 oAMPLE l M EAguREM ENT <.t.. y $ I e w,*g,' 2 t l PEWWIT { .g g. p( 7 .,,g. ReOulR EMENT .,... g c t . AM m. l MEASUREMENT [ 4 ., (, PtReeIT. ~. REoUiREm E=T S AM PLE ' 'i j usAsuREMaNT e ') / f 5 a PERMIT .r - j F. t .s ,, g d ~ ~ ~ ~ RWbutR EM EMT TELEPHONE DATE THIS DOCUM ENT 95 SiONED WITH RECOGNITION TH AT MMOW-s NAM 3/ TITLE PRINCIPAL EXECUTIVE OPPICER BMGLY M AstlNG A FALSE CERTIFIC ATION ON THIS REPORT OR / su rrOR vino DOCu M E NTs OR sNTENTiONALLv TAMrERsNo 85 11 22 ReCuTiVs G09 339-4399 J. Trejo lbd. Prot./Chan. Maruger Or,THEN.AN.Y.MONITORI.NG.C. 5 ioo.E ORANo a s u.OO.C. e.R E CRIMIN, AL . 06/URE OP PRiwCiPAU WI OEVIC M ET H A see. er se-Anu NuMetR lVEAR MO DAY E. EE. u. sees madre enese s#eteses map At >=es spo se $f 0.000 andfee amendemme OFFICER OR AUTHORIZED AGENT ggog l TYPEO OR PRINTED s prese=asens of 6esweese 6 memores and J rests.) COMMENT AND EIEPLANATION OF ANY WSOLATIONS (Referrare all efesthesents here) 3.; PAGE OF ~~ . ores scre ops ern#M T*dO WHICH M AY MOT BE USED.) 3q -- 18 i

ou3 No. Un nneer.1 renne on==wramenma o ne=Ws DescnAnos anonesonena nnPons sousy u-,.. or.m r _m_na_R __sy_aLW_ MJ0005622 487 CP.AT MI ',. Asasup_PS._E6G.._ _ _ _ _ 17 7 1 exui? Muu.Ea ...cNs

No.

7 _ E Q,jgg,y,,g,_ ige _ _ _ _ _ _ _ i. 1%I._Ed------- MONITORING PERIOD '. ramu,,.Mrr_SELM QMERM]Fr.N-------- 85 10 01 85 10 31 P'"'" ' asut.inse I.gER_AL2g!E. @ QEEE. __ ________ ,EA, oA, , EAR .o .A, NOTE: Rees8 laserveelene sneau eempseems que senn. I os n> <n us uma

a. vi arm ve.n >

<J Card 0 8 ) OuANTITY OR LOADING H Card O.J ) Ou AL8 tY OR CONCENTRATION P '"*J,'"c' eAmei.E 7 =0. os.ssi

out, e n.,s >

os,n > ous TYPE 88 Aesatvoes , A.Even gg 4 AVERAGE M ARIM ute uMITs RetNIMu.B AWERASE 80AMOMust utSITS 12.00 12.00 0 00530 1 .AmeLE 1/30 GR .EAeuRE= Em ,.' t 1/30 - Gt e e,;e ~e * * *. e * * *: 30.00 '100..'00 : PC/L ~ SUSPENED etawir i,s. noeu mEmeser s, g 0055fp 1 unnE "********"7 <5.00 0 1/30 GR OIL M O GREhSE 4*,*'s * (* *** 10.00 > PC/L { 1/30 GR eenmer .J 2 EFFIIENT GK)SS 00551 1 uunE <0.50 1/30 GR ""^*uas"*" j PETROIHM 1/30 GR . e e * *f, KT/L d is 1,1 ** * -.; *. e e c e*.e. 4 HYDROCARBCNS ,E ir - ' c ., g j. g., '. A.- ,(g . t 4. assuiaamsener. %..- a EFFI1ENT GK)SS 50050 1 .A.,LE

    • e*

mEAeuRE=Em y .t pen,v:

  • ,e e e
e. *
  • e -

.* e,*

  • u>

,' ue. e.e e - ,, t e e, e, *- PCD

rJ- ;1/30; Nkj

) c EETIMElff GROSS moeusaEmEwt y. ^ 7 ;,.,, g g y'. i 00010 1 um i.E 23.00 0 1/30 GR mEAouRE=Eur 'IDE' ERA'IURE, M DEG.CENTRIGRAIE peswear >.~ *+ e',.

  • ee*.
        • i
    • .*/*'

T.43.30** DEG.C .3/30 4 GR ~ i l ~ ~ i " GROSS 00400 1

== *i e 7.30 7.30 7.30 0 1/30 GR "'^*uRE=E=T PH ,Enseir i ,eoee: ..e-* *

  • 6.00 9.00. - SU

'1/30 GR 4 neoumEmew EFFIDENT GROSS I L; { '. MEASUREMENT u wetE t_ i ,3 1 ER..T meeUIREneEget f lj TELEP90000E DATE l$ THl. DOCUMENT IS SIGNED WITM RECOGNITION.TH AT stNOW. p* l mat 03/ TITLE PettNCIPAL EXECuTOWE OFFICER

  1. NGLY as AM 8MO A FALSE CERTIFIC ATION ON THl REPORT OR

/& J. Trej.o eureOR TiNo oOCuM E NTs OR NT ENTiON Atty TAurERiNo 85 11 22 l o09 '339-4399 ARE Crime f N.AL,. uRE Or emiN(fAL ENEcutivE W ANY MONITORING DEVICE OR METHOD O..,,B,T H, E.N,.,E,...E,E..i ,u,,.. C,s.,00,A. N.O, s,e s m.. C..aee sie,. si i r, Rad. Prot./ Gen. Manager su / FFICER OR AuTHostIRED AGENT ,8.,5 MutesER YEAR MO DAY de e. .4n .... a 3 TYPED OR PftlNTED s pesse e.s op 6er.,,. s eks e.d J 3 e.rs.) Coese84NT AND REPLANATIOes OF ANY VIOLATSONe ( Afteres.rr edi ets.c4 a.ts hera g 9 PAGE OF (REPLACE. EPA FOnes T 40 WHICH M AY NOT SE uSED.) 9..i-10 w,....,,u v er.no veg m y u.y O

paneseTTes seadnse Aeonese (8=stude GrATiONAL Pos.LuiANt oeeCNAnos tumeN.TeOte eveTam (Near.s) {/orne CW Forsaw, June /8 U dl&"*'l pesCHARGE MONITORING G^EPORT (par 2) OMJ NJ.134.R007.f nous _ fg%._MG_R __W_RI'_' um 07-m Agetup @, NJ0005622 87A GP,AT MI PX"'T Num ca ...c As.. No.... 17 7 1 _ P Q E R.57._0_ _ 1( c. _,_, _ _M ___ ET _ _.0710.1-------- MONITORING PERIOD EAGirtIY M_MN 85 10 01 85 10 31 neGdLTHt89_.N N @_ ___ _ _ _ __ _ vrAn mO oAv yrAn uO oAv anas> a2as, a4253 a m, una,3 va.3s, NOTE: Reed instrucHens Ipotese oosupleung Wele tonn. (J Card Omfy) GUANTITY OR LOADING (d Card Omfy) Qu ALITY OR CONCENTR ATION PARAmerfgm (d5-33) (344f) (1843) (46JJ) (J44s) NO. Foto,utwCV gg.pgg p (##47) AVEnAGE M AXIM uM uMITS M IN184 u M AVE =ASE 80 AMIM ut0 UNITS 1gy y, 6 ,sa,A"n"* NT 2310.00 6800.00 0 31/31 NA u pg ( peo"u'in"su"sNT GPD NA g 00310 1 .Amns "'^*""""*"r 0.16 23.00 23.00 0 1/31 GR BOD, 5-DAY, PERM 87. EFFI171NP GRDSS neovinausNr 0.97 KG/ DAY 30.00 '45.00 m/L 1/30 GR 00530 1 .Aun "***ua*"<MT 6.15 10.20 0 4/31 24 MDS, m PMDED

30.0'O 100.00 E/L 1/30 24

,n,u g,,,, g 74055 1 .A pt. caLnuet-FECAL meAsunumswr 2400.00 2400.00 2 1/31 GR -Pe* '200.00 400.00 N/100% 1/30 GR I neouin"em"eNr EFFLUINF GROSS 00010 1 meAAmns 24.00 0 21/31 GR unameNr TEMPERA'IURE, WA'IER DEG.CENTRIGRADE Pe=mir

        • s

'43.30 DEG.C 'l/30 GR macusestesNT 00400 1 .Amne 6.00 6.40 6'80 0 21/31 GR PH ""^*""'"'"' 6.00 9.00 SU 1/30 GR ,,U"."U.; y ggggg 00556 1 .. A. u" ".',N,

  • ^

<5.00 0 1/31 GR OIL AND GREASEi,' EFFLUENT GROSS' gg;t,,, MG/I, 1/30 GR .10.00 NAM 2/ TITLE PnINCIP AL EMECuTIVE OFFICER TNis DOCUMENT lal SIGNED WITN nECOGNITION TN AT KNOW. ygLbrNONE DATE INGLv M AMING A F ALSE CEnTIFIC AT80N ON TNie nEPOnT OR 8 g // *j surrOavs No DOcuurNTs On iNTrNTiONAtty Tame lNo OrrrN.ANv.se i.TOni.No oeveC.r On m eTN.Oo Ana.Cni.r.aN,~A.L J. Trej,o Tunc OP Pn:N6 AL eneCuTive 609 339-4399 85 11 22 wim ONi c. u. .C. 5 iOo ANo as u .C. si s. ir f. ..o'N Rad. Prot./Chan. Mar.ager f '6 p? cars ) FFICER OR AuYNORIZED AGENT g" NUM BER YEAR MO DAY TYPED OR PalNTED d en8 ef ss COMMENT AND EXPLAN ATiON OF ANY VIOLATIONS (Referrore all estes hments here) DIS 87A IS DISCHARGE 487A., MONITORED PRIOR TO COMB WITH DISCHARGE 487. The two Sewage plants are operated in serie<: and are considered a single point. .. r -,,,n., ,n ,,sTTi eneviOu. COITION TO or uero enspLACro spa rOmm T.Ao wNeCN may NOT se unto.: PAGEj.7 O F) g

_ D C$OC. O oesCHARG3 040NITORING REPORT (Dat;} rarer Ju==er m==== 0 de=='w) a (ne) (n-se) I'maus _* p!N_. 5 & _ _E F_._Alf _ _ _,_ _ RT0005622 489 g;gr g e 'e. ageser_P_SE_&G _._- _-----.- 17 7 1 eE==if num.c ...c.u.= -u. ,R.aQa.,gg _$_7,q,. lac -- ------- . (. s M -- M M.101.------- peONITORING PERIOD

  • . rs.aurr_S%m,_GDEMTDfr_N--------

85 10 01 85 10 31 vtan eso oAv vE4a asO oAv ESGATE N - M ---------- NOTE: Reed beskuedene haemo sempioeng this fana, i oo m onJi inm o.m na m gan, 3 (3 Ced Oudy) GU ANTITv 088 LOADEMS (4 Card Only) GUALlty 04 CONCENTR ATIOct '"."..,t,.,,8"C'SAserLE WO. I (4-JJ) (344f) (J843) (46JJ) (3441) Tves sa A e P6AAgggg I AVEAAGE $$ AElt0 Utt U NITS MINIt0Utd AVSWAGE 80 A5900Uet 4000ffW 1.00 1.00 0 1/30 GR t 00530 1 MEA.A= n=Env vE g SfY.TM, 'IUML -ca.-,l/30f @ 30.00, 100.00? PG/I. ej SUSPDEED

        • ',T,,,,

_e-e**. a e

i. m m wr c w I

0055 6 1 SA.,tg <5.00 0 1/30 GR .I OH. ABE) GREASE ~ 10.00 PG/L "s**uas"*"T

  1. 1/30 GR
  • s== e7

'.*

  • e *1
      • e, ae**.

1 4 EFFUENT GROSS 00551 1 u,LE 1.60 1/30 GR ""*""'"'"Y PE"MMM W DROCARB0tE ,E.Mir ?,,, ,,,, ', pgjy, 1/30 CR i i-U_ 4 'F i-r EET WENT GROSS I / u. 50050 1 .u.o.n.E,,, E 3 ru, ,+,,- .3 + I 4.... .E.. l EFEHENT GROSS As*UsaEMENT 4*. , /,g g.,, 00010 1 unnt 18 00 0 1/30 GR =EA*uaE=E=v ,ID@ERAM RM 43.30 mG.C. 1/30 GR' GROSS 1/30 GR 00400 1 u,,,t, 6.50 6.50 6.50 0 MEA vee =EST SU ,1/30 GR' j PH ~6.00 9.00, .e..E.*.".'t. ,,,.w D,P GROSS e A M PLE g t I ME Asum Ene ENT PEstMit I RMUIREteENT TELEptecost DATE l I Is SIGNED WITH RECOGNITION TH AT stNOW. j NAme3/ TITLE PelMCIPAL RESCUTIVE OFFICER THIS DOCUneEMY INGLY A8AsEING A F ALSE CERTIFIC ATION ON THIS REPORT OA / sureO Timo oOCu E=T. On swYEwTiOuALov TAmeEasma =EOrraimCiegEnECUvivt 609 339-4393 85 11 22, 3 J. Trejo WI esONITORI DE M ETH ARE C8tlae3NAL Rad. Prot./ Chem. Manager or,THE =.A N.Y. n E i s u.NGC. g.VIC.E 04Ano3su.OD E oo C. in sie. i F, r-seen eses==.#er e4ese sseemres meer be Maes see se 580.000 and/or assess==se ICER 04 AUTHOAIEED AGENT 00U069800 YEAR MO DAY { O YYPED on PRINTRO e peas , e op 6,e.,,e s ,nen,e.d 3 years,3 . Consis_mT Ano EmeLAN AYeoes Or AnY VsOLAT Owe ( Aese car, ss ene.<a , nen I f I PAGE; yg OF g

  1. REPLACE. EPA FOR4e 7 40 WHICH D4 AT NOT mE ustD.

. _ --.. ee .a svi eerveOue EoIYeow To oE ueEo _ _ -}}