______ _ __ - _ ____

. p' SEABROOK STATION Engineering Offica November 26, 1985 gggg New Hampshire Yankee Division United States Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406 Attention:

Mr. Richard W. Starostecki, Director Division of Project and Resident Programs

Reference:

(a) Construction Permits CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-444 (b) Telecon of October 23, 1985, D. E. Groves (YAEC)/

P. H. Hannes (YAEC) to Clifford Anderson (Region I Duty Officer)

Subject:

Interim 10CFR50.55(e):

Possible Malfunction of Figure 3050 Diaphram Valves Supplied by Dresser Industries (CDR 85-00-18)

Dear Sir:

On October 23, 1985, we reported a potential 10CFR50.55(e) deficiency, Reference (b), regarding Figure 3050 Diaphram Valves supplied by Dresser Industries. We have completed our evaluation and have determined that the deficiency is reportable.

Description of Deficiency Dresser Industries reported a possible malfunction in their Figure 3050 Diaphram Valves. The valve disc cap is capable of cocking in the disc guide and wedging, thereby not allowing the disc to move.

In this instance, the upper stem may be raised with the disc remaining in a closed or part partially closed position.

Safety Implication The safety related systems these valves are installed in are the Combustible Gas Control and Nitrogen Gas Systems.

In the Combustible Gas Control System, this valve is used in the con-tainment hydrogen analyzer lines. There are two independent and redundant hydrogen analyzer systems located outside the containment to continuously monitor the containment hydrogen concentration following a design basis loss of coolant accident. Failure of the valve (s) to open would render the hydrogen analyzers inoperative and prevent containment hydrogen sampling capabililty.

8512100536 851126

)#

PDR ADOCK 05000443 S

PDR Seabrook Station Construction Field Office P.O. Box 700

  • Seabrook, NH 03874

P:ga 2

.e..

Attsnticns, Mr. Richard Starostacki The Nitrogen Gas System valves are normally closed and are not required to operate during or _ following an accident.

Corrective Action We intend to implement the modifications to the disc guide as recommended by Dresser and will inform Region I when these modifications are complete.

Very truly yours, L dA John DeVincentis, Director Engineering and Licensing ec: Atomic Safety and Licensing Board Service List Director, Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C. 20555

e-v v:"[

William S.' Jordan, III Donald E. Chick-Diane Curran Town Manager Ha rmon, Weiss & Jordan Town of Exeter 20001.S. Street, N.W.

10 Front Street Suite 430-Exeter.,NH 03833 Washington, D.C.

20009 Brentwood Board of Selectmen Robert G. Perlis RED Dalton Road

' Office of the Executive Legal Director Brentwood, NH 03833 U.S. Nuclear Regulatory Commission Washington, DC 20555 Richard E. Sullivan, Mayor City Hall Robert A. - Backus, Esquire Newburyport, MA 01950

'116 Lowell Street P.O. Box 516 Calvin A. Canney

'Manc hester, NH 03105 City Manager City Hall

- Philip Ahrens,. Esqui re 126 Daniel Street Assistant Attorney General Portsmouth, NH 03801 Augusta, ME 04333 Dana Bisbee, Esquire Mr. John B. Tanzer Assistant Attorney Gene ral Designated Representative of Office of the Attorney General the Town of Hampton 208 State House Annex 5 Morningside' Drive Concord, NH 03301 Hampton, NH 03842 Anne Verge, Chairperson Ro berta C. Pevear Board of Selectmen Designated Representatire of Town Hall the Town of Hampton Falls South Hampton, NH 03827 Drinkwater Road

-Hampton Falls, NH 03844 Patrick J. McKeon Selectmen's Office Mrs. Sandra Gavutis 10 Central Road Designated Representative of Rye, NH 03870 the Town of Kensington RFD 1 Carole F. Kagan, Esquire East Kingston, NH 03827 Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Jo Ann Shotwell, Esquire Washington, DC 20555 Assistant ~ Attorney General Environmental Protection Bureau Mr. Angi Machiros

. Depa rtment' o f t he At torney Ge ne ral Chairman of the Board of Selectmen

. One Ashburton Place, 19th Floor Town of Newbury Boston, MA 02108 Newbury, MA 01950 Senator Gordon J. Humphrey Town Manager's Office U.S. Senate Town Hall - Friend Street Washington, DC 20510 Amesbury, MA 01913 (ATTN: Tom Burack)

Senator Gordon J. Humphrey Diana P. Randall 1 Pillsbury Street 70 Collins Street Concord, NH 03301

-Seabrook, NH 03874 (ATTN: Herb Boynton) i L.