Proposed Tech Specs 6.8.5.d Re Reactor Coolant Pump Flywheel Insp Program
ML20137X337
Person / Time
Site: Wolf Creek Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 04/15/1997
From:
WOLF CREEK NUCLEAR OPERATING CORP.
To:
Shared Package
ML20137X325 List:
References
NUDOCS 9704210244
Download: ML20137X337 (1)


Text

,,

~.

Attachmsnt IV to ET 97-0027 Paga,2.of 2 i

ADMINISTRATIVE CONTROLS PR CEDURES AND PROGRAMS (Continued) 3.

A surveillance program to ensure that the quantity of radioactivity contained in following outdoor liquid radwaste tanks that are not surrounded by liners, dikes, or walls capable of holding the tanks' contents and that do not have tank overflows and surrounding area drains connected to the liquid radwaste system, is less than the l

amount that would result in concentrations less than the l

limits of 10 CFR 20, Appendix B, Table ll, Column 2 at l

the nearest potable water supply and the nearest surface water supply in an UNRESTRICTED AREA, in the event of an uncontrolled release of the tank's contents.

a.

Reactor Makeup Water Storage Tank, b.

Refueling Water Storage Tank, c.

Condensate Storage Tank, and d.

Outside Temporary tanks, excluding demineralizer

(

vessels and the liner being used to solidify radioactive waste.

The provisions of Specifications 4.0.2 and 4.0.3 are applicable to the Explosive Gas and Storage Tank Radioactivity Monitoring Program surveillance frequencies.

b.

Reactor Cec!cnt Pump Flywheel inspection Program Each reactor coole::t pump flywheel shall be inspected per the recommendations ot Regulatory Position C.4 of Regulatory Guide 1.14, Revision 1, dated August,1975. n lieu of Position 3

iC.4.b(1) and C.4.b(2), conduct a qualmed in-place UT examination over the volume from the inner bore of the flywheel to the circle of one-half the outer radius or conduct a surface examination (MT and/or PT) of exposed l

surfaces of the removed flywheels once every

]

ten years coinciding with the inservice inspection j

l schedule as required by ASME Section XI.

j

c.. Containment Tendc,n Surveillance Program This program provides controls for monitoring tendon j

performance, including the effectiveness of the tendon j

corrosion protection medium, to ensure containment structural j

integrity. The program shall include baseline measurements J

l prior to initial plant operation as well as periodic testing thereafter. The Containment Tendon Surveillance Program, and its inspection frequencies and acceptance criteria, shall be in accordance with Wolf Creek Generating Station position on draft Revision 3 of Regulatory Guide 1.35, dated April,4980@

)

The provisions of Specifications 4.0.2 and 4.0.3 are applicable to the Containment Tendon Surveillance Program inspection frequencies.

6.9 REPORTING REQUIREMENTS i

ROUTINE REPORTS i

6.9.1 In addition to the applicable reporting requirements of Title 10, Code l

of Federal Regulations, the following reports shall be submitted to the Regional l

Administrator of the NRC R 3gional Office unless otherwise noted.

  • The volumetric examination and surface examination of the Reactor Coolant Pump "D" motor flywheel for the First 10 Year Inservice inspection Interval may l

J l

Lbe delayed one cycle to coincide with the Fall 1997 refueling outage.

WOLF CREEK UNIT 1 6-18e Amendment No. 80,97,101 9704210244'970415 l