OPERATING DATA REPORT DOCKET-NO 50-255

-DATE 02-05-86 COMPLETED BY PASmith TELEPHONE (616)764-8913 OPERATING STATUS NOTES 1.

Unit Name: Palisades 2.

Reporting Period:

860101-860131 3.

Licensed Thermal Power (MWt):

2530 4.

Nameplate Rating (Gross MWe):

811.7

~5.

' Design Electrical' Rating (Net MWe):

805 6.

Maximum Dependable' Capacity (Gross MWe): **770 7.

Maximum Dependable Capacity (Net MWe):

    • 730 8.

If Changes Occur in Capacity Ratings.(Items Number 3 through 7) since last report, give reasons:

9.

Power Level to Which Restricted, if any (Net MWe):

10.

Reasons for Restrictions, if any:

This Month Yr-to-Date Cumulative 11.

Hours In Reporting Period 744 744 123,783 12.

Number of Hours Reactor Was Critical 0

0 68,299.9 13.

Reactor Reserve Shutdown Hours

14.. Hours Generator On-Line 0

0 64,958.7

15. Unit Reserve Shutdown Hours 16.

Gross Thermal Energy Generated (MWH) 0 0

135,602,040 17.

Gross Electrical Energy Generated (MWH) 0 0

42,217,400-18 Net Electrical Energy Generated (MWH) 0 0

39,741,360 19.

Unit Service Factor 0

0 52.5 20.

Unit Availability Factor 0

0 52.5 21.

Unit Capacity Factor (Using MDC Net) 0 0

  • 50.4
22. Unit Capacity Factor (Using DER Net) 0 0

-39.9 23.

Unit Forced Outage Rate 0

0 31.4 24.

Shutdowns Scheduled Over Next Six Months (Type, Date and Duration of Each):-

25.

If Shut Down at End of Report Period, Estimated Date of Start Up: February 15,1986 26.

Units in Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION n* Based on condenser backpressure

  • Weighted Average (635 MWe used as,MDC Net prior to October 1985)

OC0185-0001B-0T!03 ype fI

_=

g.f. [

m.:

~

N

, t. c.:.

AVERAGE DAILY.' UNIT POWER LEVEL lDOCKET NO.

50-255

UNIT-Palisades DATE 02-05-86' COMPLETED BY PASmith l TELEPHONE (616)764-8913 MONTH January 1986

-DAY AVERAGE DAILY POWER LEVEL _

DAY

' AVERAGE DAILY; POWER LEVEL (MWe-Net)

(MWe-Net),.

1 0

.17 0

2 0

18 0

3 0

,19 0

4 0

20 0'

5 0

21 0'

6 0

2' 0-7 0

23 0

8 0

24

^0 9

0 25 "

10 0

26 0

11 0

27 0

12 0

28 0

13 0

29 0

^'

14 0

30 0

15 0

31 0

16 0

INSTRUCTIONS:

On this - format, list the average. daily unit. power leve1 'in MWe-Net _ for each:

~

day in the. reporting month. Compute to the nearent whole^ megawatt,

~0C01Q5-0001C-OP03-

~

lh '-

..e

. + ~.

l'

' O.;

. s DOCKE' NO.

50-255~

17-"

f;i.

UNIT SN'NS AND POWER REDUCIIONS UNIT IAME-Palisades:

1 LTE 02-05-86' COMPLETEL BY PASeith REPORT PONTH

.Tanuary 1986 TELEPHONI (616)-764-8913 1

2 No.

Date Type Duration Reason Method of Licensee Systp Compogont Cause & Corrective (Hours)

Shuting Event Code Code Action to.

3 Down Reactor Report #

Prevent Recurrence 9

1 113085 S

744 C

1 I

b d

l l

I 1.-

2.

3.

4.

5.

~

F:; Forced.

Reason:

Method:

. Exhibit G - Instructions Exhibit I - Same Source

' S: ' Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data l

B-Maintenance or Test.

2-Manual Scram Entry Sheets for Licensee C-Refueling 3-Automatic Scram Event Report.(LER) File D-Regulatory Restriction 4-Other (Explain)

. NLTEG-0161)

(

- E-Operator Training & License j

Examination l

.F-Administrative C-Operational Error (Explain)

H-Other (Explain) c-l

- OC0185-0001D-OP03 1.

.i'

,..,va, f,... >~

+

I '

},

K

,a

..,,m I

Y l..;-

SUMMARY

OF ' OPERATING ' EXPERIENCE -FOR -JANUARY 1986 ':.

I

~ The Plant remained shut down for refueling during the entire month.of January.

L

('.'

I.

i

y lp

- 4 l.

l i

?

4.

L OC0185-0001E-OP03; l'

- w4

  • ,... r Consumers Power Company Pahsades Nuclear Plant. 27780 Blue Star Memonal Highway, Covert. MI 49043 February 5, 1986 US Nuclear Regulatory Commission Mail and Records Section Washington, DC 20555 LICENSE REPORT OF MONTHLY OPERATING DATA DPR-20, DOCKET NO 50-255 Enclosed is a copy of the Monthly Operating Data and a Summary of Operating Experience for the Palisades Nuclear Plant for the month of January 1986.

uM]

A Dewey VanDenBerg Reactor Engineer CC: KMHaas, Palisades GHGoralski, Palisades JGKeppler, USNRC JRSchepers, Palingdes KWBerry, P24-614B RAFenech, Palisades Resident Inspector, Palisades DLHackett, P11-228B LABrown, P21-317 GWBruckmann, Div of Radiological Health Services, Lansing, Michigan SMierzwa, Michigan Dept of Labor RCallen, Michigan Public Service Commission Records Center, INPO, Atlanta, GA RWTaylor, CE, Palisades AAAlatalo, Palisades EWRaciborski, P26-204A Document Control, 950*22*35*10/L GHG86-002

\\

4 1

OC0185-0001A-0F03