r VIHOINIA ELucTuzc Axn Powzu Coxiwxy RICHMOND, VIRGINIA 232G1 W.L.STEWANT

~

Vacu Panasomwr wuci.=i oFEMATION.

^

December 4, 1935 Mr. Harold R. Denton, Director Serial No. 85-290A Office of Nuclear Reactor Regulation N0/DJV:acm Attn: Mr. Edward J. Butcher, Acting Chief Docket Nos. 50-338 i

Operating Reactors Branch No. 3 50-339 Division of Licensing License Nos. NPF-4 U.S. Nuclear Regulatory Commission NPF-7 e

Washington, D.C. 20555

\\

Gentlemen:

A hII.DINIAELECTRICANDPOVERCOMPANY NORTH ANNA POWER STATION UNITS NO. 1 AND 2 PROPOSED TECHNICAL SPECIFICATION CHANGES Our letter of April 30, 1985 (Serial No. 290) requested amendments,in the form of changes to the Technical Specifications, for North Anna Units No.

I and 2.

The proposed changes involved updating the pressure-temperature limit curves to be applied during heatup and cooldown, in accordance with 10 CFR 50 Appendix G and H.

It was recently brought to our attention by Mr. Leon Engle of your staff that Attachment 3 to our letter, entitled

" Safety Evaluation",, contains several typographical errors which should be corrected.

The errors, which are contained in Table 2 of the attachment, do not affect the conclusions of the safety evaluation, or the proposed changes to the Technical Specifications. A corrected Table 2 is attached.

We apologize for any problems these errors may have caused you and your.

staff.

\\.

_.i Very trul yours, s

~

W. L. Stewart

^

Attachment _

\\

d

<.3 8512100267 851204 PDR ADOCK 05000338 P

PD$

1

i l

l

[

VauorwA Er.nciare awn Powra CowrAwr T Mr. Harold R. Denton I

i.

T i

1 cc:

Dr. J. Nelson Grace Regional Administrator j

NRC Region II i

j Mr. Morris W. Branch j

NRC Resident Inspector North Anna Power Station i

I

)

Mr. Charles Price Department of Health 109 Governor Street Richmond, Virginia 23219 Mr. Leon B. Engle l

~

i NRC North Anna Project Manager Operating Reactors Brhnch No. 3 Division of Licensing 5

l i.

l t

---. :-a-

.-z--.

- -- = - -... - - - -. - - - - - - _ -. - _ _ - - -. = _ - -,... -

TABLE 2 COMPARISON OF CURRENT AND' PROPOSED PORV SETPOINTS CURRENT PROPOSED UNIT TEMPERATURE RANGE SETPOINT TEMPERATURE RANGE SETP0 INT 1

< 140 'F

< 430 psig

< 185 F

< 350 psig

< 320 F

< 505 psig

' < 375 F

< 420 psig 2

< 140 F

< 405 psig

< 190 F

< 375 psig

<.340 F

< 475 psig

< 340 F

< 520 psig l

l-p i

=

l l

t l.i f

.I

?

b 84R629NAS168~

r

TABLE 2 COMPARISON OF CURRENT AND PROPOSED PORV SETPOINTS CURRENT PROPOSED UNIT TEMPERATURE RANGE SETPOINT TEMPERATURE RANGE SETPOINT 1

< 140 *F

< 430 psig

< 185 F

< 350 psig

< 320 *F

< 505 psig

< 375 *F

< 420 psig i

2

< 140 F

< 405 psig

< 190 F

< 375 psig

< 340 *F

< 475 psig

< 340 *F

< 520 psig i

l l

I I

1 l

84R629NAS168

_ _ _ _ _ _ _ _ _ _