Text
GPU Nuclear Corporation g
gf Post Office Box 480 Route 441 South Middletown, Pennsylvania 17057 0191 717 944 7621 TELEX 84-2386 Writer's Direct Dial Number:
(717) 948-8461 4410-85-L-0195 Document ID 0326A September 27, 1985 TMI Program Office Attn: Dr. B. J. Snyder Program Director US Nuclear Regulatory Commission Washington, DC 20555
Dear Dr. Snyder:
Three Mile Island Nuclear Station, Unit 2 (TMI-2)
Operating License No. OPR-73 Docket No. 50-320 Revision 2 To Boron Hazards Analysis in response to your letter, dated August 6, 1985, which forwarded approval of the Defueling dater Cleanup System (DWCS) Tecnnical Evaluation Report (TER), Revision 2 of the " Hazards Analysis: Potential for Baron Dilution of Reactor Coolant System" is forwarded for your information.
The basic analysis assessed the potential for baron dilution of the TMI-2 reactor coolant system during a variety of pre-defueling recovery activities. This analysis has been expanded in scope to include DWCS operation. Revision 2 consists of the addition of Appendix E, "Defueling Water Cleanup" and revised " Purpose" and " Applicability / Scope" sections.
Substantial portions of the base document (e.g., static conditions in level control mode) remain applicable.
8510040293 850927 Sincerely, PDR ADOCK 05000320 P
)
f kuted Rh.
F. R. Standerfer Vice President / Director, TMI-2 FRS/RDW/eml q
Attachment I
cc: Deputy Program Director - TMI Program Office, Dr. W. D. Travers I{
GPU Nuclear Corporation is a subsidiary of the General Public Utilities Corporation
.