_ _ _ _ _ - -

4 i

l' a

ENCLOSURE 1 NOTICE OF DEVIATION i

i i

Duke Power Company Docket Nos. 50-369 and 50-370 l

McGuire Units 1 and 2 License Nos. NPF-9 and NPF-17 1

The following deviations were identified during an inspection conducted on October 15 - November 8, 1985.

McGuire FSAR Section 6.4.3 and Table 6.2.3-4 stipulate that inplace testing

{

of the Control Room Area Ventilation Systems (CV) were in compliance with.

l Regulatory Guide 1.52 (Revision 2, March 1978) which in turn obligates the licensee to ANSI N510-1975.

Contrary to those commitments, a review of completed preoperational tests performed on McGuire Control Room Area Ventflation Trains A and B revealed that Regulatory. Guide 1.52 and/or ANSI N510-1975 were not adhered to in that the air-aerosol uniformity tests were not performed as specified.

This deviation is applicable to Units 1 and 2.

Please provide, in writing within 30 days of the date of this Notice, a description of corrective actions regarding these deviations, actions taken to avoid further deviations, and the dates when these actions were or will be completed.

l j.

Security or safeguards information should be submitted as an enclosure to facilitate withholding it from public disclosure as required by 10 CFR 2.790(d) or 10 CFR 73.21.

Date:

DEC 0 41985 8512100197 851204 PDR ADOCK 05000369 G

PDR li -... -

.