ML20137W084

From kanterella
Jump to navigation Jump to search
Forwards Inservice Insp Rept for Spring 1985 10-yr Outage. Overview of Insp Results Listed in Vol I & Detailed Exam Repts Included in Vols II-IV.Four Categories of Insps Performed,Including Exams of Pipe Supports & Welds
Date released: 06/02/2020 Download: ML20137W084


Inservice Insp Rept for Spring 1985 10-yr Outage,Vols I-IV. Four Categories of Insps Performed,Including Exams of Pipe Supports,Welds & Other Pressure Retaining Components,Igscc, Per NUREG-0313 & IE Bulletins 80-07 & 81-13
ML20140G825
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 02/06/1986
From:
EBASCO SERVICES, INC.
To:
References
RTR-NUREG-0313, RTR-NUREG-313
Download: ML20140G825 (3200)
Forwards Inservice Insp Rept for Spring 1985 10-yr Outage. Overview of Insp Results Listed in Vol I & Detailed Exam Repts Included in Vols II-IV.Four Categories of Insps Performed,Including Exams of Pipe Supports & Welds
ML20137W079
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 02/06/1986
From: Brons J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: MULLER D R
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0313, RTR-NUREG-313
Download: ML20137W079 (3)