ML20137V938

From kanterella
Jump to navigation Jump to search
Responds to Violations Noted in Insp Repts 50-424/85-43 & 50-425/85-32.Corrective Actions:Equipment Storage & Maint Program Developed & Implemented,Valves Cleaned & Securely Wrapped & Personnel Assigned to Monitor Storage Conditions
ML20137V938
Person / Time
Site: Vogtle  Southern Nuclear icon.png
Issue date: 11/15/1985
From: Foster D
GEORGIA POWER CO.
To: Walker R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
GN-743, NUDOCS 8512100127
Download: ML20137V938 (4)


Text

Georgia Power Company q

Post Office Box 282 Waynesboro, Georgia 30830 Telephone 404 554 9%1. Ext. 3360 404 724-8114. Ext. 3360 US DEC 2 P2: 2 4 GeorgiaPower D. O. Fost.,

. Vice President and Project the southern electro Sys!6m Generamanager November 15, 1985 Vogtle Project United States Nuclear Regulatory Commission Region II File: X78G10 Suite 2900 Log: GN-743 101 Marietta Street,. Northwest Atlanta, Georgia 30323

Reference:

50-424/85-43, 50-425/85-32 Attention: Mr. Roger D. Walker The Georgia Power Company wishes to submit the following information concerning the vi.olation identified in NRC inspection report 50-424/85-43 and 50-425/85-32:

~ Violation 50-424/85-43-01, 50-425/85-32-01; " Failure to Provide Adequate Protection to Safety-Related Components During In-Plant Storage" Severity Level IV The violation identified five valves and one electrical panel which were not adequately protected from damage or contamination in accordance with established procedures.

Georgia Power Company offers the following response pursuant to the criteria of 10 CFR 2.201:

1.

Georgia Power Company acknowledges the violation as identified in the NRC inspection report.

As a point of ' clarification, the identification numbers given in the NRC inspection report for the four Unit 2 control valves located on Level C of the Unit 2 Containment are in error.

The correct identification numbers for these valves, in the order listed in section 15.b of the inspection report, are 2HV-152128, 2HV-15212C, 2HV-15216B, and 2HV-15216C.

2.

Georgia Power Company has developed and implemented an equipment storage and maintenance program at the Vogtle Electric Generating Plant ~ which meets the applicable reqitirements of ANSI N45.2.2 -

1972Property "ANSI code" (as page type) with input value "ANSI N45.2.2 -</br></br>1972" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process..

This program prescribes specific requirements for the protection of stored equipment from camage or deterioration and provides periodic preventive maintenance and routine surveillances to provide reasonable assurance that the program requirements are met.

However, considering the amount of equipment controlled in the storage and maintenance program and the amount of construction and testing activity in and around in-plant storage areas, it is expected that occasional discrepancies in program implementation e

will occur.

Identified discrepancies are documented, evaluated, f

C and resolved as required to ensure that affected equipment will satisfactorily perform its design functions.

B512100127 851115 1

PDR ADOCK 05000424 g g G

PDR 1501

Paga Two A review of the discrepancies cited in the violation involving four valves in the Unit 2 Containment indicates that no sandblasting operations were performed in the area but that the grit on exterior valve surfaces was the result of a " dust blowdown" performed in the area during the weekend of August 31, 1985.

Building " dust blowdown" is a controlled activity which includes a walkdown prior to blowdown operations to ensure that equipment in the area is protected as required from dust contamination.

Blowdown operations were not scheduled to be performed in the Unit 2 Containment on the weekend of August 31, 1985, so the walkdown was not performed for equipment in that area.

However, blowdown crews working near the Unit 2 Containment, with conscientious intentions, expanded the scheduled assignments by performing a " dust blowdown" in the Unit 2 Containment since the manpower and equipment were already in the general area.

As a result, dust and grit was blown onto the four valves which were stored in the area without the protective covering normally provided during blowdown operations.

In the case of the Refueling Water Storage Tank Suction Inlet Valve to the Residual Heat Removal System (Valve No. HV 8812A), the bonnet and gate of the valve was removed for hydrolazing of the associated piping as part of the system flushing program.

The bonnet and gate were carefully wrapped and protected upon rt.moval while hydrolazing activities continued for approximately one month.

A Construction Department Deviation Report, PP-11723, had identified a needed seal lip repair on the valve.

Apparently, in~ the course of various examinations of the valve for the pending work to resolve the Deviation Report, the valve was left uncovered for a brief period.

From an evaluation of this discrepancy by the Nuclear Operations Department, it is estimated that the valve was uncovered for about thirty-six hours.

Train "A" Remote Shutdown Panel 1-1605-P5-SDA has been turned over by Construction to Nuclear Operations and has been entered into the Preoperational Maintenance Program governed by Startup Manual procedure SUM-25.

Much work is being conducted in and around the remote shutdown panels. An evaluation of this discrepancy by Nuclear Operations was unable to determine the cause of the door being open at the time of 'the NRC inspection but it is apparently the result of heavy work traffic in the area.

3.

The four valves stored in the Unit 2 Containment were cleaned and securely wrapped on September 9, 1985.

All electrical enclosure connections were also cleaned, capped, and taped.

The bent bracket on valve 2HV-15216C was identified in Deviation Report 10-1437 to ensure proper evaluation and resolution.

A followup inspection on November 6, 1985, verified that the cleanliness and protection of the valves was being maintained.

Valve HV-8812A and Remote Shutdown Panel 1-1605-P5-SDA were examined and no evidence was found of damage or deterioration as a result of the cited discrepancies.

Valve HV-8812A was promptly covered J

Pagm Thr:e after the discrepancy was identified and the door to the Remote Shutdown Panel - was closed.

Disassembled valves under Nuclear Operations control are rarely stored in the plant.

Plant procedures require that disassembled valves be cleaned, identified, wrapped or covered, and properly stored to prevent damage or deterioration.

Valve parts are usually stored in the Operations Warehouse until reassembly unless their physical size or weight makes this impractical.

In evaluating the violation, Nuclear Operations attempted to conduct a review of other valves which were disassembled for flushing purposes but no other disassembled valves were stored in the plant at that time.

Since September 30, 1985, the remote shutdown panels have been added to a maintenance surveillance list which provides a check of the panels each shift.

The panel doors have been found open on other occasions since the violation was identified.

The maintenance surveillance check includes verification of area cleanliness, air filter cleanliness, door closure, and work in progress in the area.

4.

To prevent further violations regarding the protection of stored equipment under Construction Department control, Georgia Power Compaay and Pullman Power Products, the piping contractor, have assigned personnel to monitor field storage conditions for valves and other equipment during each shift to ensure that covers and other protective methods are properly maintained.

Additional controls have also been established for " dust blowdown" operations to ensure that prerequisite walkdowns are accomplished.

Relative to equipment controlled by Nuclear Operations, the relatively short durations of the cited discrepancies indicate that the Preoperational Maintenance Program is reasonably effective in protecting equipment from damage and deterioration and no action to. prevent recurrence is necessary.

It should be noted that safety-related equipment will be thoroughly tested before being placed into service.

5.

All corrective actions relative to this violation have been completed.

This response contains no proprietary information and may be placed in the NRC Public Document Room.

Your truly,

/

I

/

. O. Foster REF/D0F/tdm xc: See Distribution on Page 4

Page Four xc:

U. S. Nuclear Regulatory Commission Document Control Desk Washington, D.C.

20555 R. J. Kelly -

J. A. Bailey G. Bockhold R. E. Conway O. Batum P. D. Rice G. F. Head H. H. Gregory C. S. McCall (0PC)

J. T. Beckham W. T. Nickerson E. L. Blake, Jr.

R. A. Thomas D. R. Altman (Shaw, et. al.)

D. E. Dutton D. L. Kinnsch (BPC)

J. E. Joiner Sr. Resident (NRC)

J. L. Vota (W)

(Troutman, et. al.)

'R. H. Pinson L. T. Gucwa D. C. Teper (GANE)

B. M. Guthrie C. E. Belflower L. Fowler (LEAF)

E. D. Groover F. B. Marsh (BPC)

T. Johnson (ECPG)

~

R. W. McManus G. A. McCarley

.